Accuracy of percutaneous lumbar pedicle screw placement using the oblique or "owl's-eye" view and novel guidance technology

被引:37
作者
Idler, Cary [2 ]
Rolfe, Kevin W. [1 ]
Gorek, Josef E. [3 ]
机构
[1] Harbor UCLA Med Ctr, Dept Orthopaed Surg, Torrance, CA 90509 USA
[2] Orthopaed Specialists N Carolina, Wake Forest, NC USA
[3] Kaiser Oakland Med Ctr, Spine Ctr, Oakland, CA USA
关键词
percutaneous pedicle screw; image guidance; owl's-eye projection; lumbar spine; FACET-JOINT VIOLATION; TRANSPEDICULAR INSTRUMENTATION; IMAGE GUIDANCE; SPINAL INSTRUMENTATION; BIOMECHANICAL ANALYSIS; VERTEBRAL ROTATION; FIXATION; COMPLICATIONS; FLUOROSCOPY; NAVIGATION;
D O I
10.3171/2010.4.SPINE09580
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. This study was conducted to assess the in vivo safety and accuracy of percutaneous lumbar pedicle screw placement using the owl's-eye view of the pedicle axis and a new guidance technology system that facilitates orientation of the C-arm into the appropriate fluoroscopic view and the pedicle cannulation tool in the corresponding trajectory. Methods. A total of 326 percutaneous pedicle screws were placed from L-3 to S-1 in 85 consecutive adult patients. Placement was performed using simple coaxial imaging of the pedicle with the owl's-eye fluoroscopic view. Neuro Vision, a new guidance system using accelerometer technology, helped align the C-arm trajectory into the owl's-eye view and the cannulation tool in the same trajectory. Postoperative fine-cut CT scans were acquired to assess screw position. Medical records were reviewed for complications. Results. Five of 326 screws breached a pedicle cortex all breaches were less than 2 mm for an accuracy rate of 98.47%. Five screws violated an adjacent facet joint. All were at the S-1 superior facet and included in a fusion. No screw violated an adjacent mobile facet or disc space. There were no cases of new or worsening neurological symptoms or deficits for an overall clinical accuracy of 100%. Conclusions. The owl's-eye technique of coaxial pedicle imaging with the C-arm fluoroscopy, facilitated by Neuro Vision, is a safe and accurate means by which to place percutaneous pedicle screws for degenerative conditions of the lumbar spine. This is the largest series reported to use the oblique or owl's-eye projection for percutaneous pedicle screw insertion. The accuracy of percutaneous screw insertion with this technique meets or exceeds that of other reported clinical series or techniques. (DOI: 10.3171/2010.4.SPINE09580)
引用
收藏
页码:509 / 515
页数:7
相关论文
共 46 条
  • [1] ROENTGENOGRAPHIC EVALUATION OF VERTEBRAL ROTATION
    BENSON, DR
    SCHULTZ, AB
    DEWALD, RL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (08) : 1125 - 1129
  • [2] Sterility of C-arm fluoroscopy during spinal surgery
    Biswas, Debdut
    Bible, Jesse E.
    Whang, Peter G.
    Simpson, Andrew K.
    Grauer, Jonathan N.
    [J]. SPINE, 2008, 33 (17) : 1913 - 1917
  • [3] Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery
    Bose, B
    Wierzbowski, LR
    Sestokas, AK
    [J]. SPINE, 2002, 27 (13) : 1444 - 1450
  • [4] Accuracy of pedicle screw placement in lumbar vertebrae
    Castro, WHM
    Halm, H
    Jerosch, J
    Malms, J
    Steinbeck, J
    Blasius, S
    [J]. SPINE, 1996, 21 (11) : 1320 - 1324
  • [5] Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine
    Chen, Zhiming
    Zhao, Jie
    Xu, Hao
    Liu, Aigang
    Yuan, Jiandong
    Wang, Cong
    [J]. EUROPEAN SPINE JOURNAL, 2008, 17 (11) : 1476 - 1480
  • [6] COMPLICATIONS OF LUMBAR SPINAL-FUSION WITH TRANSPEDICULAR INSTRUMENTATION
    DAVNE, SH
    MYERS, DL
    [J]. SPINE, 1992, 17 (06) : S184 - S189
  • [7] COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS
    ESSES, SI
    SACHS, BL
    DREYZIN, V
    [J]. SPINE, 1993, 18 (15) : 2231 - 2239
  • [8] Navigated pedicle screw placement:: Experimental comparison between CT- and 3D fluoroscopy-based techniques
    Geerling, Jens
    Goesling, Thomas
    Goesling, Anna
    Ortega, Gil
    Kendoff, Daniel
    Citak, Musa
    Krettek, Christian
    Huefner, Tobias
    [J]. COMPUTER AIDED SURGERY, 2008, 13 (03) : 157 - 166
  • [9] ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO
    GERTZBEIN, SD
    ROBBINS, SE
    [J]. SPINE, 1990, 15 (01) : 11 - 14
  • [10] Intraoperative three-dimensional navigation for pedicle screw placement
    Grützner, PA
    Beutler, T
    Wendl, K
    von Recum, J
    Wentzensen, A
    Nolte, LP
    [J]. CHIRURG, 2004, 75 (10): : 967 - 975