Hard X-ray submicrometer tomography of human brain tissue at Diamond Light Source

被引:0
作者
Khimchenko, A. [1 ]
Bikis, C. [1 ]
Schulz, G. [1 ]
Zdora, M-C [2 ,3 ]
Zanette, I. [2 ]
Vila-Comamala, J. [2 ]
Schweighauser, G. [4 ]
Hench, J. [4 ]
Hieber, S. E. [1 ]
Deyhle, H. [1 ]
Thalmann, P. [1 ]
Mueller, B. [1 ]
机构
[1] Univ Basel, Biomat Sci Ctr, Dept Biomed Engn, Allschwil, Switzerland
[2] Diamond Light Source, Harwell Sci & Innovat Campus, Didcot OX11 0DE, Oxon, England
[3] UCL, Dept Phys & Astron, London WC1E 6BT, England
[4] Basel Univ Hosp, Inst Pathol, Dept Neuropathol, Basel, Switzerland
来源
X-RAY MICROSCOPY CONFERENCE 2016 (XRM 2016) | 2017年 / 849卷
基金
瑞士国家科学基金会;
关键词
PHASE-CONTRAST; RESOLUTION;
D O I
10.1088/1742-6596/849/1/012030
中图分类号
TH742 [显微镜];
学科分类号
摘要
There is a lack of the necessary methodology for three-dimensional (3D) investigation of soft tissues with cellular resolution without staining or tissue transformation. Synchrotron radiation based hard X-ray in-line phase contrast tomography using single-distance phase reconstruction (SDPR) provides high spatial resolution and density contrast for the visualization of individual cells using a standard specimen preparation and data reconstruction. In this study, we demonstrate the 3D characterization of a formalin-fixed paraffin-embedded (FFPE) human cerebellum specimen by SDPR at the Diamond-Manchester Imaging Branchline I13-2 (Diamond Light Source, UK) at pixel sizes down to 0.45 mu m. The approach enables visualization of cerebellar layers (Stratum moleculare and Stratum granulosum), the 3D characterization of individual cells (Purkinje, stellate and granule cells) and can even resolve some subcellular structures (nucleus and nucleolus of Purkinje cells). The tomographic results are qualitatively compared to hematoxylin and eosin (H&E) stained histological sections. We demonstrate the potential bene fits of hard X-ray microtomography for the investigations of biological tissues in comparison to conventional histology.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] X-ray micro-Tomography at the Advanced Light Source
    MacDowell, A. A.
    Parkinson, D. Y.
    Haboub, A.
    Schaible, E.
    Nasiatka, J. R.
    Yee, C. A.
    Jameson, J. R.
    Ajo-Franklin, J. B.
    Brodersen, C. R.
    McElrone, A. J.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [2] Multimodal hard X-ray imaging of a mammography phantom at a compact synchrotron light source
    Schleede, Simone
    Bech, Martin
    Achterhold, Klaus
    Potdevin, Guillaume
    Gifford, Martin
    Loewen, Rod
    Limborg, Cecile
    Ruth, Ronald
    Pfeiffer, Franz
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 525 - 529
  • [3] Biological soft X-ray tomography on beamline 2.1 at the Advanced Light Source
    Le Gros, Mark A.
    McDermott, Gerry
    Cinquin, Bertrand P.
    Smith, Elizabeth A.
    Do, Myan
    Chao, Weilun L.
    Naulleau, Patrick P.
    Larabell, Carolyn A.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 1370 - 1377
  • [4] Ptychographic X-ray computed tomography at a high-brilliance X-ray source
    Sala, Simone
    Batey, Darren J.
    Prakash, Anupama
    Ahmed, Sharif
    Rau, Christoph
    Thibault, Pierre
    OPTICS EXPRESS, 2019, 27 (02): : 533 - 542
  • [5] Computational cell quantification in the human brain tissues based on hard X-ray phase-contrast tomograms
    Hieber, Simone E.
    Bikis, Christos
    Khimchenko, Anna
    Schulz, Georg
    Deyhle, Hans
    Thalmann, Peter
    Chicherova, Natalia
    Rack, Alexander
    Zdora, Marie-Christine
    Zanette, Irene
    Schweighauser, Gabriel
    Hench, Jurgen
    Mueller, Bert
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [6] Ambient-pressure endstation of the Versatile Soft X-ray (VerSoX) beamline at Diamond Light Source
    Held, Georg
    Venturini, Federica
    Grinter, David C.
    Ferrer, Pilar
    Arrigo, Rosa
    Deacon, Liam
    Garzon, Wilson Quevedo
    Roy, Kanak
    Large, Alex
    Stephens, Christopher
    Watts, Andrew
    Larkin, Paul
    Hand, Matthew
    Wang, Hongchang
    Pratt, Linda
    Mudd, James J.
    Richardson, Thomas
    Patel, Suren
    Hillman, Michael
    Scott, Stewart
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1153 - 1166
  • [7] Hard X-ray phase imaging and tomography using a grating interferometer
    David, C.
    Weitkamp, T.
    Pfeiffer, F.
    Diaz, A.
    Bruder, J.
    Rohbeck, T.
    Groso, A.
    Bunk, O.
    Stampanoni, M.
    Cloetens, P.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (6-7) : 626 - 630
  • [8] Hard X-ray fluorescence tomography - an emerging tool for structural visualization
    de Jonge, Martin D.
    Vogt, Stefan
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2010, 20 (05) : 606 - 614
  • [9] Bending magnet source: A radiation source for X-ray phase contrast tomography
    Dhal, B. B.
    Peele, A. G.
    McMahon, P. J.
    De Carlo, F.
    Nugent, K. A.
    RADIATION PHYSICS AND CHEMISTRY, 2006, 75 (11) : 2004 - 2007
  • [10] Experimental comparison of grating- and propagation-based hard X-ray phase tomography of soft tissue
    Lang, S.
    Zanette, I.
    Dominietto, M.
    Langer, M.
    Rack, A.
    Schulz, G.
    Le Duc, G.
    David, C.
    Mohr, J.
    Pfeiffer, F.
    Mueller, B.
    Weitkamp, T.
    JOURNAL OF APPLIED PHYSICS, 2014, 116 (15)