A Fluorinated Dendrimer-Based Nanotechnology Platform New Contrast Agents for High Field Imaging

被引:17
|
作者
Huang, Zhihua [1 ]
Sengar, Raghvendra S. [1 ,2 ]
Nigam, Archana [1 ]
Abadjian, Marie-Caline [3 ]
Potter, Douglas M. [1 ,4 ]
Grotjahn, Douglas B. [3 ]
Wiener, Erik C. [1 ,2 ]
机构
[1] Univ Pittsburgh, Hillman Canc Ctr, Inst Canc, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
[3] San Diego State Univ, Dept Chem & Biochem, San Diego, CA 92182 USA
[4] Univ Pittsburgh, Dept Biostat, Grad Sch Publ Hlth, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院;
关键词
fluorinated dendrimer; contrast agent; (19)F MRI; diffusion coefficient; relaxation times; F-19; MAGNETIC-RESONANCE; BIOMEDICAL APPLICATIONS; DRUG-DELIVERY; 1.5; TESLA; MRI; NANOPARTICLES; CELLS; SPECTROSCOPY; CHELATE; DESIGN;
D O I
10.1097/RLI.0b013e3181ee6e06
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We aimed to develop a directly detected magnetic resonance imaging (MRI) contrast agent for use with high fields based on a nanoscale fluorinated dendrimer-based platform for (19)F MRI and overcome some of the problems with (19)F MRI. Materials and Methods: The dendrimers were prepared in a convergent manner by making the appropriate dendron, followed by coupling to a central core. The dendrons were prepared by attaching 3 equivalents of the fluorinated amino acid to the 3 carboxylic acids of the repeat branch unit followed by deprotection of the amine branch point, and either coupling to another repeat branch unit (increasing the generation G) or used directly allowing the precise growth of the dendrimer. The size of the dendrimers was determined by diffusion nuclear magnetic resonance (NMR) spectroscopy. The toxicity of the dendrimers was measured using the MTT assay. Fluorine longitudinal relaxation time measurements were performed on a Bruker ACP-500 NMR using a saturation recovery experiment at 470.59 MHz frequency. Healthy 150 g Sprague-Dawley female rats were imaged using a dendrimer solution. Results: The size of the dendrimers is generally less than 3 nm, 2 orders of magnitude smaller than the size of the perfluorocarbon nanoparticles (about 200 nm). The longitudinal relaxation time, T(1), decreases with increasing dendrimer generation. A significant improvement in relaxation rate and signal-to-noise ratio can be achieved by either the chemical modification of the dendrimer with a gadolinium-chelate or by the physical addition of exogenous contrast agent. Although the dendrimers with fluorine in the surface layer are toxic, this toxicity is easily reduced by burying the fluorine further into the dendrimer interior. (19)F MR images of the rat using the dendrimer solution were rapidly obtained at 7 Tesla, the strong contrast in the heart generated by the dendrimer can be seen. Conclusions: A novel fluorinated dendrimer-based nanotechnology platform in 19F MRI and a new bifunctional DOTA chelate were prepared and characterized. We introduce 2 methods for reducing the 19F longitudinal relaxation time: (a) Increasing the generation; (b) covalent and noncovalent introduction of Gd(III)-chelates. A new bifunctional Gd(III)-chelate is presented. The investigations of imaging on rats suggest potential importance of the dendrimers in (19)F MRI application.
引用
收藏
页码:641 / 654
页数:14
相关论文
共 50 条
  • [21] Dendrimer-based drug and imaging conjugates: design considerations for nanomedical applications
    Menjoge, Anupa R.
    Kannan, Rangaramanujam M.
    Tomalia, Donald A.
    DRUG DISCOVERY TODAY, 2010, 15 (5-6) : 171 - 185
  • [22] Characterization of nanoparticle-based contrast agents for molecular magnetic resonance imaging
    Shan, Liang
    Chopra, Arvind
    Leung, Kam
    Eckelman, William C.
    Menkens, Anne E.
    JOURNAL OF NANOPARTICLE RESEARCH, 2012, 14 (09)
  • [23] Dendrimer-based nanoprobe for dual modality magnetic resonance and fluorescence imaging
    Talanov, Vladimir S.
    Regino, Celeste A. S.
    Kobayashi, Hisataka
    Bernardo, Marcelino
    Choyke, Peter L.
    Brechbiel, Martin W.
    NANO LETTERS, 2006, 6 (07) : 1459 - 1463
  • [24] Enhancing magnetic resonance imaging with contrast agents for ultra-high field strengths
    Kuda-Wedagedara, Akhila N. W.
    Allen, Matthew J.
    ANALYST, 2014, 139 (18) : 4401 - 4410
  • [25] Multicolor imaging of lymphatic function with two nanomaterials: quantum dot-labeled cancer cells and dendrimer-based optical agents
    Kobayashi, Hisataka
    Ogawa, Mikako
    Kosaka, Nobuyuki
    Choyke, Petet L.
    Urano, Yasuteru
    NANOMEDICINE, 2009, 4 (04) : 411 - 419
  • [26] Recent Advances of Bioresponsive Nano-Sized Contrast Agents for Ultra-High-Field Magnetic Resonance Imaging
    Hu, Hailong
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [27] Magnetic Nanoparticle-Based High-Performance Positive and Negative Magnetic Resonance Imaging Contrast Agents
    Tegafaw, Tirusew
    Liu, Shuwen
    Ahmad, Mohammad Yaseen
    Saidi, Abdullah Khamis Ali Al
    Zhao, Dejun
    Liu, Ying
    Nam, Sung-Wook
    Chang, Yongmin
    Lee, Gang Ho
    PHARMACEUTICS, 2023, 15 (06)
  • [28] Hypoxia-targeting dendritic MRI contrast agent based on internally hydroxy dendrimer for tumor imaging
    Han, Yuxin
    Zhou, Xiaoxuan
    Qian, Yue
    Hu, Hongjie
    Zhou, Zhuxian
    Liu, Xiangrui
    Tang, Jianbin
    Shen, Youqing
    BIOMATERIALS, 2019, 213
  • [29] High-Density Lipoprotein-Based Contrast Agents for Multimodal Imaging of Atherosclerosis
    Skajaa, Torjus
    Cormode, David P.
    Falk, Erling
    Mulder, Willem J. M.
    Fisher, Edward A.
    Fayad, Zahi A.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2010, 30 (02) : 169 - 176
  • [30] Characterization of nanoparticle-based contrast agents for molecular magnetic resonance imaging
    Liang Shan
    Arvind Chopra
    Kam Leung
    William C. Eckelman
    Anne E. Menkens
    Journal of Nanoparticle Research, 2012, 14