Hepatic iron quantification by atomic absorption spectrophotometry: Full validation of an analytical method using a fast sample preparation

被引:9
作者
Wortmann, A. C.
Froehlich, P. E.
Pinto, R. B.
Magalhaes, R. B.
Alvares-da-Silva, M. R.
Ferreira, J. J.
Silveira, T. R.
机构
[1] Univ Fed Rio Grande do Sul, Fac Med, Programa Posgrad Ciencias Aplicadas Gastroenterol, Hosp Clin Porto Alegre,Ctr Pesquisas, Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Fac Farm, Programa Posgrad Ciencias Farmaceut, Lab Prod Padroes Secundarios, Porto Alegre, RS, Brazil
来源
SPECTROSCOPY-AN INTERNATIONAL JOURNAL | 2007年 / 21卷 / 03期
关键词
iron; liver; quantitative methods; atomic absorption spectrophotometry; validation; LIVER; HEMOCHROMATOSIS; DIAGNOSIS; TISSUE; FRESH; ZINC;
D O I
10.1155/2007/761029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Atomic absorption spectrophotometry is considered the method of choice for hepatic iron quantification. The objective of the present study was to perform full validation assays of hepatic iron quantification by atomic absorption spectrophotometry, using a fast sample preparation procedure, following the guidelines from the International Conference on Harmonization. The following parameters were evaluated: specificity, linearity/range, precision, accuracy, limit of detection and limit of quantification. A good linear correlation was found (0.9948) in the concentration range evaluated (20-120 ppb). The relative standard deviations were below 15% for accuracy, and below 10% for both day-to-day reproducibility and within-days precision, and the repeatability of injections was 0.65%. Limit of detection was 2 ppb, and limit of quantification was 6 ppb. Fresh bovine liver tissue was used to evaluate the procedure of collecting samples by liver biopsies. These findings indicate that hepatic iron quantification by atomic absorption spectrophotometry can be reliably performed at the established conditions, and suggest the method is suitable for further use in clinical practice. Hepatic iron quantification by AAS is validated by the experiments performed in the present study.
引用
收藏
页码:161 / 167
页数:7
相关论文
共 42 条
[41]   Accurate and sensitive analytical method for trace iron determination in clove tea and tap water samples by slotted quartz tube-flame atomic absorption spectrometry after its preconcentration with supramolecular solvent-based liquid-phase microextraction [J].
Yildirmaz, Busra Bekar ;
Golcu, Aysegul ;
Zaman, Buse Tugba ;
Kasa, Nursu Aylin ;
Bakirdere, Emine Gulhan ;
Bakirdere, Sezgin .
CHEMICAL PAPERS, 2021, 75 (08) :4157-4164
[42]   Accurate and sensitive analytical method for trace iron determination in clove tea and tap water samples by slotted quartz tube-flame atomic absorption spectrometry after its preconcentration with supramolecular solvent-based liquid-phase microextraction [J].
Buşra Bekar Yıldırmaz ;
Ayşegül Gölcü ;
Buse Tuğba Zaman ;
Nursu Aylin Kasa ;
Emine Gülhan Bakırdere ;
Sezgin Bakırdere .
Chemical Papers, 2021, 75 :4157-4164