Hepatic iron quantification by atomic absorption spectrophotometry: Full validation of an analytical method using a fast sample preparation

被引:9
作者
Wortmann, A. C.
Froehlich, P. E.
Pinto, R. B.
Magalhaes, R. B.
Alvares-da-Silva, M. R.
Ferreira, J. J.
Silveira, T. R.
机构
[1] Univ Fed Rio Grande do Sul, Fac Med, Programa Posgrad Ciencias Aplicadas Gastroenterol, Hosp Clin Porto Alegre,Ctr Pesquisas, Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Fac Farm, Programa Posgrad Ciencias Farmaceut, Lab Prod Padroes Secundarios, Porto Alegre, RS, Brazil
来源
SPECTROSCOPY-AN INTERNATIONAL JOURNAL | 2007年 / 21卷 / 03期
关键词
iron; liver; quantitative methods; atomic absorption spectrophotometry; validation; LIVER; HEMOCHROMATOSIS; DIAGNOSIS; TISSUE; FRESH; ZINC;
D O I
10.1155/2007/761029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Atomic absorption spectrophotometry is considered the method of choice for hepatic iron quantification. The objective of the present study was to perform full validation assays of hepatic iron quantification by atomic absorption spectrophotometry, using a fast sample preparation procedure, following the guidelines from the International Conference on Harmonization. The following parameters were evaluated: specificity, linearity/range, precision, accuracy, limit of detection and limit of quantification. A good linear correlation was found (0.9948) in the concentration range evaluated (20-120 ppb). The relative standard deviations were below 15% for accuracy, and below 10% for both day-to-day reproducibility and within-days precision, and the repeatability of injections was 0.65%. Limit of detection was 2 ppb, and limit of quantification was 6 ppb. Fresh bovine liver tissue was used to evaluate the procedure of collecting samples by liver biopsies. These findings indicate that hepatic iron quantification by atomic absorption spectrophotometry can be reliably performed at the established conditions, and suggest the method is suitable for further use in clinical practice. Hepatic iron quantification by AAS is validated by the experiments performed in the present study.
引用
收藏
页码:161 / 167
页数:7
相关论文
共 42 条
[31]   Development and validation of an analytical method for the extraction, identification, and quantification of multi-mycotoxins in beer using a modified QuEChERS procedure and UHPLC-MS/MS [J].
Barbosa, Ana Cristina ;
da Silva, Fabiano Aurelio ;
da Silva, Lucas Pinto ;
Azevedo Vargas, Eugenia ;
Veloso Terra, Julio Cesar ;
Alves Dos Santos, Eliene ;
Augusti, Rodinei .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2020, 37 (12) :2135-2148
[32]   A Simple and Green Vortex-Assisted Switchable Solvent-Based Microextraction Method by Using Schiff Base Ligand Complexation for Iron Determination in Mineral Spring Water Samples Prior to Slotted Quartz Tube Flame Atomic Absorption Spectrophotometry [J].
Nursu Aylin Kasa ;
Emine Gülhan Bakirdere ;
Sezgin Bakirdere .
Water, Air, & Soil Pollution, 2020, 231
[33]   A Simple and Green Vortex-Assisted Switchable Solvent-Based Microextraction Method by Using Schiff Base Ligand Complexation for Iron Determination in Mineral Spring Water Samples Prior to Slotted Quartz Tube Flame Atomic Absorption Spectrophotometry [J].
Kasa, Nursu Aylin ;
Bakirdere, Emine Gulhan ;
Bakirdere, Sezgin .
WATER AIR AND SOIL POLLUTION, 2020, 231 (08)
[34]   Fusion method for sample preparation for isotopic composition determination of boron in refractory materials by thermal ionization mass spectrometry with validation using dissolved and purified samples [J].
Bhushan, K. Sasi ;
Goswami, Preeti G. ;
Venkatesh, K. ;
Kumar, Sanjukta A. ;
Rao, Radhika M. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 467
[35]   Multiresidue Method for Quantification of Sulfonamides and Trimethoprim in Tilapia Fillet by Liquid Chromatography Coupled to Quadrupole Time-of-Flight Mass Spectrometry Using QuEChERS for Sample Preparation [J].
Nunes, Katia S. D. ;
Assalin, Marcia R. ;
Vallim, Jose H. ;
Jonsson, Claudio M. ;
Queiroz, Sonia C. N. ;
Reyes, Felix G. R. .
JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2018, 2018
[36]   Solid phase extraction method for the determination of iron, lead and chromium by atomic absorption spectrometry using Amberite XAD-2000 column in various water samples [J].
Elci, Latif ;
Kartal, Aslihan A. ;
Soylak, Mustafa .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 153 (1-2) :454-461
[37]   Preparation of Calibration Curves for the Direct Determination of Trace Level of Zinc in High Purity Iron and Steel Samples by Graphite Furnace Atomic Absorption Spectrometry Using Solid Sampling Technique [J].
Tsushima, Shinya ;
Yamaoka, Shingo ;
Bai, Junling ;
Minami, Hirotsugu ;
Takahashi, Nobuo ;
Inoue, Sadanobu ;
Atsuya, Ikuo .
BUNSEKI KAGAKU, 2009, 58 (08) :771-775
[38]   Selection of Iron Absorption Lines for Sequential Internal Standard Method for Accurate Determination of Nickel in Steel Samples by Flame Atomic Absorption Spectrometry Using a High-resolution Continuum-light-source Apparatus [J].
Itagaki, Toshiko ;
Ashino, Tetsuya ;
Wagatsuma, Kazuaki .
BUNSEKI KAGAKU, 2017, 66 (07) :515-520
[39]   Reverse Phase-High-Performance Liquid Chromatography (RP-HPLC) Method Development and Validation Using Analytical Quality-by-Design Approach for Determination of Isoliquiritigenin in Bulk and Biological Sample [J].
Nihal, P. Mohamed ;
Mohapatra, Debasish ;
Manir, Alam Mohd Adil Alam ;
Harish, Vancha ;
Singh, Sachin Kumar ;
Lad, Sakshi Upendra ;
Sutrapu, Srinivas ;
Saini, Sumant ;
Mohd, Sharfuddin .
ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2024, 22 (08) :409-424
[40]   Development and validation of an automated method for the liquid chromatographic determination of sotalol in plasma using dialysis and trace enrichment on a cation-exchange pre-column as on-line sample preparation [J].
Chiap, P ;
Ceccato, A ;
Buraglia, BM ;
Boulanger, B ;
Hubert, P ;
Crommen, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (5-6) :801-814