Lateral pelvic displacement during walking: retest reliability of a new method of measurement

被引:11
作者
Dodd, KJ [1 ]
Morris, ME
Matyas, TA
Wrigley, TV
Goldie, PA
机构
[1] La Trobe Univ, Sch Physiotherapy, Fac Hlth Sci, Bundoora, Vic 3083, Australia
[2] La Trobe Univ, Sch Psychol, Fac Sci & Technol, Bundoora, Vic 3083, Australia
[3] Victoria Univ Technol, Ctr Rehabil Exercise & Sport Sci, Melbourne, Vic 3000, Australia
关键词
gait; locomotion; pelvis; physical therapy;
D O I
10.1016/S0966-6362(98)00013-7
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study examined the retest reliability of a new method of measuring the amplitude and symmetry of lateral pelvic displacement (LPD) during walking. Previous methods of quantifying LPD did not consider variations in walking direction or enable quantification of side-to-side symmetry of LPD. Therefore, the new method was developed to measure the amplitude and symmetry of LPD relative to the base of support provided by the feet. Three-dimensional motion analysis was used to collect the coordinates of markers placed on the sacrum and heels of 20 unimpaired adults. Subjects performed three 10 m walking trials at their preferred speed. Between trial 1 and 2 the markers were removed and then reattached. Between trial 2 and 3 the markers remained attached. Retest reliability was high for consecutive measurements of amplitude of LPD (ICC (2,1) = 0.91), and marker reattachment did not affect the degree of reliability (ICC (2,1)= 0.94). The reliability was also high for consecutive measurements of symmetry of LPD (ICC (2,1)= 0.80). Marker reattachment did however reduce the reliability of symmetry measures (ICC (2,1) = 0.54). This study provides data on the retest reliability of a new method of measuring LPD in unimpaired subjects against which the performance of patients can be compared. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 15 条
[1]  
Bobath B., 1990, Adult Hemiplegia: Evaluation and Treatment
[2]  
Carr JH., 1987, A motor relearning programme for stroke, V2nd ed.
[3]   AN INVESTIGATION ON THE ACCURACY OF 3-DIMENSIONAL SPACE RECONSTRUCTION USING THE DIRECT LINEAR TRANSFORMATION TECHNIQUE [J].
CHEN, L ;
ARMSTRONG, CW ;
RAFTOPOULOS, DD .
JOURNAL OF BIOMECHANICS, 1994, 27 (04) :493-500
[4]  
DODD KJ, IN PRESS QUANTIFYING
[5]  
Guilford J.P., 1978, FUNDAMENTAL STAT PSY, V6th
[6]   FITTING OF MATHEMATICAL FUNCTIONS TO BIOMECHANICAL DATA [J].
JACKSON, KM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (02) :122-124
[7]   CONTROL OF WHOLE-BODY BALANCE IN THE FRONTAL PLANE DURING HUMAN WALKING [J].
MACKINNON, CD ;
WINTER, DA .
JOURNAL OF BIOMECHANICS, 1993, 26 (06) :633-644
[8]   MECHANICAL ENERGY OF WALKING OF STROKE PATIENTS [J].
OLNEY, SJ ;
MONGA, TN ;
COSTIGAN, PA .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1986, 67 (02) :92-98
[9]  
*PEAK PERF TECHN, 1994, US REF MAN VERS 5 2
[10]   THE MAJOR DETERMINANTS IN NORMAL AND PATHOLOGICAL GAIT [J].
SAUNDERS, JBDM ;
INMAN, VT ;
EBERHART, HD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1953, 35-A (03) :543-558