Reliability and concurrent validity of a mobile application to measure thoracolumbar range of motion in low back pain patients

被引:10
作者
Macedo, Liane de Brito [1 ]
Borges, Daniel Tezoni [1 ]
Melo, Samara Alencar [1 ]
Aires da Costa, Karinna Sonalya [1 ]
Sousa, Catarina de Oliveira [1 ]
Brasileiro, Jamilson Simoes [1 ]
机构
[1] Univ Fed Rio Grande do Norte, Dept Physiotherapy, Neuromuscular Performance Anal Lab LAPERN, Natal, RN, Brazil
关键词
Data accuracy; reproducibility of results; spine; LUMBAR SPINE; BUBBLE INCLINOMETER; SHOULDER RANGE; SMARTPHONE; MOVEMENT;
D O I
10.3233/BMR-181396
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Smartphone devices have been used to measure range of motion (ROM) in different joints. OBJECTIVE: To verify the concurrent validity of thoracolumbar ROM using a mobile application and a digital inclinometer, as well as the intrarater reliability of individuals with and without back pain. METHODS: One investigator was responsible for measuring the ROM during the evaluations performed on 20 asymptomatic subjects and 20 symptomatic subjects in two consecutive days. RESULTS: Regarding to the concurrent validity, the Intraclass Correlation Coefficients (ICC) were classified as very good for all analyzed movements. For intrarater reliability, the mobile application had ICC varying between good and very good for the symptomatic subjects and very good for asymptomatic subjects. CONCLUSIONS: The mobile application may be considered a valid and reliable tool to assess thoracolumbar ROM for both asymptomatic and chronic low back pain subjects.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 31 条
[1]   The revised CONSORT statement for reporting randomized trials: Explanation and elaboration [J].
Altman, DG ;
Schulz, KF ;
Moher, D ;
Egger, M ;
Davidoff, F ;
Elbourne, D ;
Gotzsche, PC ;
Lang, T .
ANNALS OF INTERNAL MEDICINE, 2001, 134 (08) :663-694
[2]   Reliability of lumbar movement dysfunction tests for chronic low back pain patients [J].
Bauer, Christoph Michael ;
Heimgartner, Martin ;
Rast, Fabian Marcel ;
Ernst, Markus Josef ;
Oetiker, Sarah ;
Kool, Jan .
MANUAL THERAPY, 2016, 24 :81-84
[3]   Chronic low back pain sufferers exhibit freezing-like behaviors when asked to move their trunk as fast as possible [J].
Bourigua, Imen ;
Simoneau, Emilie M. ;
Leteneur, Sebastien ;
Gillet, Christophe ;
Ido, Ghassan ;
Barbier, Franck .
SPINE JOURNAL, 2014, 14 (07) :1291-1299
[4]  
Bruyneel A.-V., 2015, KINESITHERAPIE REV, V15, P74
[5]   Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion [J].
Charlton, Paula C. ;
Mentiplay, Benjamin F. ;
Pua, Yong-Hao ;
Clark, Ross A. .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2015, 18 (03) :262-267
[6]   Velocity of Lordosis Angle during Spinal Flexion and Extension [J].
Consmueller, Tobias ;
Rohlmann, Antonius ;
Weinland, Daniel ;
Druschel, Claudia ;
Duda, Georg N. ;
Taylor, William R. .
PLOS ONE, 2012, 7 (11)
[7]   Three-dimensional kinematics of the lumbar spine during treadmill walking at different speeds [J].
Feipel, V ;
De Mesmaeker, T ;
Klein, P ;
Rooze, M .
EUROPEAN SPINE JOURNAL, 2001, 10 (01) :16-22
[8]  
Galvao CZ, 2012, MAN THER POSTUROLOGY, V10, P399
[9]  
Ganzalez Gabrielle Zoldan, 2014, Fisioter. Pesqui., V21, P365, DOI 10.590/1809-2950/13088921042014
[10]  
Gil Fernandez M., 2012, Fisioterapia, V34, P73, DOI [10.1016/j.ft.2011.12.004, DOI 10.1016/J.FT.2011.12.004]