Tailoring selective laser melting process for titanium drug-delivering implants with releasing micro-channels

被引:57
作者
Hassanin, Hany [1 ,2 ]
Finet, Laurane [2 ]
Cox, Sophie C. [3 ]
Jamshidi, Parastoo [2 ]
Grover, Liam M. [3 ]
Shepherd, Duncan E. T. [4 ]
Addison, Owen [5 ]
Attallah, Moataz M. [2 ]
机构
[1] Kingston Univ, Sch Mech & Aerosp Engn, London SW15 3DW, England
[2] Univ Birmingham, Sch Met & Mat, Edgbaston B15 2TT, England
[3] Univ Birmingham, Sch Chem Engn, Edgbaston B15 2TT, England
[4] Univ Birmingham, Sch Engn, Dept Mech Engn, Edgbaston B15 2TT, England
[5] Univ Birmingham, Sch Dent, Edgbaston B15 2TT, England
基金
英国工程与自然科学研究理事会;
关键词
Selective laser melting; Titanium alloys; Medical implants; Surface roughness; 316L STAINLESS-STEEL; MECHANICAL-PROPERTIES; BIOMEDICAL APPLICATIONS; ORTHOPEDIC IMPLANTS; POROSITY; MICROSTRUCTURE; ALLOYS; PARTS; FLOW;
D O I
10.1016/j.addma.2018.01.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The use of drug-delivering implants can minimise implant failure due to infection through a controlled medication release into the surrounding tissues. In this study, selective laser melting (SLM) was employed to manufacture Ti-6Al-4 V samples, with internal reservoirs and releasing Micro-channels (MCs) to simulate what could be a drug-delivering orthopaedic or dental implant. Investigations were performed to optimise the design and SLM process parameters required to create the releasing MCs with minimum dimensional deviation to allow a controlled dosing of the drugs, while considering the process impact on the surface roughness and porosity of the builds. The build orientation, internal contour spacing, and laser process parameters were varied to assess their effect on the resolution of the MCs with diameters of similar to 200-500 mu m. It was found that, vertically oriented channels were found to have the least dimensional deviation from the target dimensions compared with horizontally-oriented or inclined channels. The dimensional deviation of the MCs was found in range of 220-427 mu m, while the horizontal surface roughness (R-a) was in range of 1.46-11.46 mu m and the vertical surface roughness (R-a) was in range of 8.5-13.23 mu m when applying energy density varying from of 27-200 J/mm(3). It was found that, there was a clear correlation between the energy density with both dimensional deviation and horizontal surface roughness, while no correlation was found for the vertical' surface roughness. The study identified the optimum conditions to manufacture drug-delivering metallic implants, creating hollow samples with releasing MCs equivalent diameter of similar to 271 mu m, horizontal surface roughness (R-a) of 4.4 mu m, vertical surface roughness of (R-a) 9.2 mu m, and build porosity of 1.4% using an internal contour of 150 mu m and energy density of 35.7 J/mm(3).
引用
收藏
页码:144 / 155
页数:12
相关论文
共 46 条
  • [1] [Anonymous], 2011, GLOBAL HLTH AGING WO, P2
  • [2] Drug delivery from internally implanted biomedical devices used in traumatology and in orthopedic surgery
    Arruebo, Manuel
    Vilaboa, Nuria
    Santamaria, Jesus
    [J]. EXPERT OPINION ON DRUG DELIVERY, 2010, 7 (05) : 589 - 603
  • [3] Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants
    Bandyopadhyay, Amit
    Espana, Felix
    Balla, Vamsi Krishna
    Bose, Susmita
    Ohgami, Yusuke
    Davies, Neal M.
    [J]. ACTA BIOMATERIALIA, 2010, 6 (04) : 1640 - 1648
  • [4] Design of a 3D printer head for additive manufacturing of sugar glass for tissue engineering applications
    Begin-Drolet, Andre
    Dussault, Marc-Andre
    Fernandez, Stephanie A.
    Larose-Dutil, Jeanne
    Leask, Richard L.
    Hoesli, Corinne A.
    Ruel, Jean
    [J]. ADDITIVE MANUFACTURING, 2017, 15 : 29 - 39
  • [5] Mechanical characterization and modeling of graded porous stainless steel specimens for possible bone implant applications
    Bender, Steve
    Chalivendra, Vijaya
    Rahbar, Nima
    El Wakil, Sherif
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2012, 53 : 67 - 73
  • [6] The Epidemiology of Revision Total Knee Arthroplasty in the United States
    Bozic, Kevin J.
    Kurtz, Steven M.
    Lau, Edmund
    Ong, Kevin
    Chiu, Vanessa
    Vail, Thomas P.
    Rubash, Harry E.
    Berry, Daniel J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 45 - 51
  • [7] Dimensional analysis for the definition of the influence of process parameters in selective laser melting of Ti-6Al-4V alloy
    Cardaropoli, Francesco
    Alfieri, Vittorio
    Caiazzo, Fabrizia
    Sergi, Vincenzo
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2012, 226 (B7) : 1136 - 1142
  • [8] Fatigue Life of Titanium Alloys Fabricated by Additive Layer Manufacturing Techniques for Dental Implants
    Chan, Kwai S.
    Koike, Marie
    Mason, Robert L.
    Okabe, Toru
    [J]. METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2013, 44A (02): : 1010 - 1022
  • [9] Adding functionality with additive manufacturing: Fabrication of titanium-based antibiotic eluting implants
    Cox, Sophie C.
    Jamshidi, Parastoo
    Eisenstein, Neil M.
    Webber, Mark A.
    Hassanin, Hany
    Attallah, Moataz M.
    Shepherd, Duncan E. T.
    Addison, Owen
    Grover, Liam M.
    [J]. MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 64 : 407 - 415
  • [10] Processing and mechanical properties of porous 316L stainless steel for biomedical applications
    Dewidar, Montasser M.
    Khalil, Khalil A.
    Lim, J. K.
    [J]. TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2007, 17 (03) : 468 - 473