Dosimetric comparison of integral dose for different techniques of craniospinal irradiation

被引:3
|
作者
Goswami, Brijesh [1 ,2 ]
Jain, Rakesh Kumar [2 ]
Yadav, Suresh [3 ]
Kumar, Sunil [1 ]
Oommen, Saji [1 ]
Manocha, Sapna [1 ]
Jadav, Genesh K. [1 ]
机构
[1] Indraprastha Apollo Hosp, Dept Radiotherapy, New Delhi 110076, India
[2] Shobhit Inst Engn & Technol, Dept Phys, Meerut 250110, Uttar Pradesh, India
[3] Gandhi Med Coll, Dept Radiotherapy, Bhopal, Madhya Pradesh, India
关键词
craniospinal irradiation; helical; integral dose; intensity-modulated radiotherapy; RapidArc; three-dimensional conformal radiation therapy; VOLUMETRIC MODULATED ARC; HELICAL TOMOTHERAPY; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; FEASIBILITY; TOMODIRECT; RAPIDARC;
D O I
10.1017/S1460396920000424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: Comparison of the integral dose (ID) delivered to organs at risk (OAR), non-target body and target body by using different techniques of craniospinal irradiation (CSI). Materials and methods: Ten CSI patients (medulloblastoma) already planned and treated either with linear accelerator three-dimensional conformal radiation therapy (Linac-3DCRT) technique or with linear accelerator RapidArc (Linac-RapidArc) technique by Novalis-Tx Linac machine have been analysed. Retrospectively, these patients are again planned on Radixact-X9 Linac with Helical, Direct-3DCRT and Direct-intensity-modulated radiation therapy (Direct-IMRT) techniques. The dose prescription to planning target volume brain (PTV-Brain) and PTV-Spine is 36 Gy in 20 fractions and is kept the same for all techniques. The target body, non-target body, OARs and total body dose are compared. Results: ID is lowest in the RapidArc plan for every patient in comparison to Helical and Direct-IMRT. The ID for Body-PTV was found slightly higher in the RapidArc plan in comparison to 3DCRT plans. But there is better normal tissue sparing for most of the OARs in RapidArc plans if it compares with 3DCRT plans. Findings: RapidArc is a better alternative for the treatment of CSI. It provides better target coverage and better OARs sparing from any other treatment techniques.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [21] Dosimetric comparison of five different techniques for craniospinal irradiation across 15 European centers: analysis on behalf of the SIOP-E-BTG (radiotherapy working group)
    Seravalli, Enrica
    Bosman, Mirjam
    Lassen-Ramshad, Yasmin
    Vestergaard, Anne
    Oldenburger, Foppe
    Visser, Jorrit
    Koutsouveli, Efi
    Paraskevopoulou, Chryssa
    Horan, Gail
    Ajithkumar, Thankamma
    Timmermann, Beate
    Fuentes, Carolina-Sofia
    Whitfield, Gillian
    Marchant, Thomas
    Padovani, Laetitia
    Gamier, Eloise
    Gandola, Lorenza
    Meroni, Silvia
    Hoeben, Bianca A. W.
    Kusters, Martijn
    Alapetite, Claire
    Losa, Sandra
    Goudjil, Farid
    Magelssen, Henriette
    Evensen, Morten Egeberg
    Saran, Frank
    Smyth, Gregory
    Rombi, Barbara
    Righetto, Roberto
    Kortmann, Rolf-Dieter
    Janssens, Geert O.
    ACTA ONCOLOGICA, 2018, 57 (09) : 1240 - 1249
  • [22] Craniospinal irradiation for medulloblastoma tumors: Retrospective analysis of dosimetric comparison-An institutional study
    Devi, Rama
    Singh, Balbir
    Basandrai, Deepak
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2025, 21 (01) : 40 - 48
  • [23] SUPINE LINAC TREATMENT VERSUS TOMOTHERAPY IN CRANIOSPINAL IRRADIATION: PLANNING COMPARISON AND DOSIMETRIC EVALUATION
    Hong, J. Y.
    Kim, G. W.
    Kim, C. U.
    Cheon, G. S.
    Son, S. H.
    Lee, J. Y.
    Lee, Y. H.
    Lee, J. H.
    Choi, B. O.
    Kim, Y. S.
    Lee, S. N.
    Jang, H. S.
    Kang, Y. N.
    Yoon, S. C.
    RADIATION PROTECTION DOSIMETRY, 2011, 146 (1-3) : 364 - 366
  • [24] Dosimetric and clinical evaluation of a novel craniospinal irradiation technique
    Zeeb, B.
    Thorwarth, D.
    Christ, G.
    Dohm, O.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S272 - S273
  • [25] Dosimetric Comparison Of Dose&Volume Change By Different Planning Techniques In Hodgkin Lymphoma
    Altay, A.
    Kurt, M.
    Cona, P.
    Tunc, S.
    Abakay, C. Demiroz
    Cetintas, S. Kahraman
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1834 - S1834
  • [26] Dosimetric comparison of different motion management techniques
    Ehrbar, S.
    Johl, A.
    Stieb, S.
    Riesterer, O.
    Stark, L. S.
    Guckenberger, M.
    Klock, S.
    Lang, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S482 - S483
  • [27] Radiation doses to normal tissues during craniospinal irradiation: Improvement of the dose to the eye and lens, dosimetric study
    Mostafa, Mohamed Farouk
    Helal, Azza
    Noaaman, Mohamed Farid
    ALEXANDRIA JOURNAL OF MEDICINE, 2011, 47 (04) : 291 - 298
  • [28] Which techniques and delineation for craniospinal irradiation?
    Padovani, L.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S348 - S348
  • [29] Craniospinal Irradiation of Pediatric Medulloblastoma, Dosimetric Comparison between Helical Tomotherapy, and Conventional Radiation Therapy
    Hegazy, Mohamed W.
    Shehadeh, Maamoun
    MIDDLE EAST JOURNAL OF CANCER, 2022, 13 (04) : 701 - 707
  • [30] Dosimetric evaluation of the dose calculation accuracy of different algorithms for two different treatment techniques during whole breast irradiation
    Acar, Hilal
    Altinok, Ayse Yildirim
    Cebe, Mehmet Siddik
    JOURNAL OF RADIATION ONCOLOGY, 2019, 8 (03) : 337 - 347