Dosimetric comparison of integral dose for different techniques of craniospinal irradiation

被引:3
|
作者
Goswami, Brijesh [1 ,2 ]
Jain, Rakesh Kumar [2 ]
Yadav, Suresh [3 ]
Kumar, Sunil [1 ]
Oommen, Saji [1 ]
Manocha, Sapna [1 ]
Jadav, Genesh K. [1 ]
机构
[1] Indraprastha Apollo Hosp, Dept Radiotherapy, New Delhi 110076, India
[2] Shobhit Inst Engn & Technol, Dept Phys, Meerut 250110, Uttar Pradesh, India
[3] Gandhi Med Coll, Dept Radiotherapy, Bhopal, Madhya Pradesh, India
关键词
craniospinal irradiation; helical; integral dose; intensity-modulated radiotherapy; RapidArc; three-dimensional conformal radiation therapy; VOLUMETRIC MODULATED ARC; HELICAL TOMOTHERAPY; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; FEASIBILITY; TOMODIRECT; RAPIDARC;
D O I
10.1017/S1460396920000424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: Comparison of the integral dose (ID) delivered to organs at risk (OAR), non-target body and target body by using different techniques of craniospinal irradiation (CSI). Materials and methods: Ten CSI patients (medulloblastoma) already planned and treated either with linear accelerator three-dimensional conformal radiation therapy (Linac-3DCRT) technique or with linear accelerator RapidArc (Linac-RapidArc) technique by Novalis-Tx Linac machine have been analysed. Retrospectively, these patients are again planned on Radixact-X9 Linac with Helical, Direct-3DCRT and Direct-intensity-modulated radiation therapy (Direct-IMRT) techniques. The dose prescription to planning target volume brain (PTV-Brain) and PTV-Spine is 36 Gy in 20 fractions and is kept the same for all techniques. The target body, non-target body, OARs and total body dose are compared. Results: ID is lowest in the RapidArc plan for every patient in comparison to Helical and Direct-IMRT. The ID for Body-PTV was found slightly higher in the RapidArc plan in comparison to 3DCRT plans. But there is better normal tissue sparing for most of the OARs in RapidArc plans if it compares with 3DCRT plans. Findings: RapidArc is a better alternative for the treatment of CSI. It provides better target coverage and better OARs sparing from any other treatment techniques.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [1] Dosimetric Comparison of Craniospinal Irradiation Using Different Tomotherapy Techniques
    Zhang, X.
    Penagaricano, J.
    Han, E. Y.
    Morrill, S.
    Hardee, M.
    Liang, X.
    Gupta, S. K.
    Corry, P. M.
    Ratanatharathom, V.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (04) : 440 - 446
  • [2] Dosimetric Comparison of Craniospinal Irradiation Using Different Tomotherapy Techniques
    Zhang, X.
    Penagaricano, J.
    Han, E.
    Liang, X.
    Morrill, S.
    Hardee, M.
    Gupta, S.
    Vaneerat, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 310 - 310
  • [3] CRANIOSPINAL IRRADIATION TECHNIQUES: A DOSIMETRIC COMPARISON OF PROTON BEAMS WITH STANDARD AND ADVANCED PHOTON RADIOTHERAPY
    Yoon, Myonggeun
    Shin, Dong Ho
    Kim, Jinsung
    Kim, Jong Won
    Kim, Dae Woong
    Park, Sung Yong
    Lee, Se Byeong
    Kim, Joo Young
    Park, Hyeon-Jin
    Park, Byung-Kiu
    Shin, Sang Hoon
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (03): : 637 - 646
  • [4] Comparison of Treatment Planning Parameters of Different Radiotherapy Techniques for Craniospinal Irradiation
    Goswami B.
    Jain R.K.
    Yadav S.
    Kumar S.
    Oommen S.
    Manocha S.
    Jadhav G.K.
    Iranian Journal of Medical Physics, 2021, 18 (03) : 164 - 170
  • [5] Pediatric Craniospinal Irradiation with RapidArc: A Feasibility Study and Dosimetric Comparison
    Atwood, T.
    Soltys, S.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06) : 3220 - +
  • [6] Current practices of craniospinal irradiation techniques in Turkey: a comprehensive dosimetric analysis
    Senkesen, Oeznur
    Tezcanli, Evrim
    Alkaya, Fadime
    Ispir, Burcin
    Catli, Serap
    Yesil, Abdullah
    Bezirganoglu, Ebrar
    Turan, Sezgi
    Koeksal, Canan
    Gueray, Guelay
    Haciislamoglu, Emel
    Durmus, Ismail Faruk
    Cavdar, Seyma
    Aksu, Telat
    Colak, Nurten
    Kuecuekmorkoc, Esra
    Dogan, Mustafa
    Ercan, Tuelay
    Karakoese, Fatih
    Alpan, Vildan
    Ceylan, Cemile
    Poyraz, Goekhan
    Nalbant, Nilguel
    Kinay, Seyda
    Ipek, Servet
    Kayalilar, Namik
    Tatli, Hamza
    Zhu, Mingyao
    RADIATION ONCOLOGY, 2024, 19 (01)
  • [7] IMRT for Craniospinal Irradiation: A Comparison with Traditional Techniques
    Studenski, M.
    Biswas, T.
    Xiao, Y.
    Harrison, A.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [8] A Dosimetric Comparison Between Multiple Junction Shifts and Single Gradient Dose Junction for Craniospinal Irradiation (CSI)
    Hadley, A.
    Ding, G.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [9] DOSIMETRIC COMPARISON OF TOMOTHERAPY IMRT AND 3DCRT FOR CRANIOSPINAL IRRADIATION
    Bandurska, A.
    Piotrowski, T.
    Skrobala, A.
    Ryczkowski, A.
    Kazmierska, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S259 - S259
  • [10] Craniospinal Irradiation Techniques
    Scarlatescu, Ioana
    Virag, Vasile
    Avram, Calin N.
    TIM14 PHYSICS CONFERENCE: PHYSICS WITHOUT FRONTIERS, 2015, 1694