EFFECTS OF HYDRATION ON SCINTIGRAPHIC GLOMERULAR FILTRATION RATE MEASURED USING INTEGRAL AND PLASMA VOLUME METHODS IN DOGS WITH SUSPECTED RENAL DISEASE

被引:8
作者
Westgren, Frida [1 ]
Ley, Charles J. [3 ]
Kampa, Naruepon [2 ]
Lord, Peter [3 ]
机构
[1] Diagnost Imaging, Uppsala, Sweden
[2] Fac Vet Med, Khon Kaen, Thailand
[3] Clin Sci, Uppsala, Sweden
关键词
GFR; integral method; kidney; plasma volume method; scintigraphy; EXTRACELLULAR FLUID VOLUME; GAMMA-CAMERA RENOGRAPHY; BODY-SURFACE AREA; ACID; TC-99M-DTPA; NORMALIZATION; VARIABILITY; CLEARANCE; PLOT;
D O I
10.1111/vru.12173
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The current standard scintigraphic method for estimating glomerular filtration rate (GFR) in dogs is the integral method, which normalizes renal GFR to body weight. The plasma volume method, that is normalizing GFR to plasma volume, has been reported to be more physiologically correct. The aim of this prospective study was to test the effect of hydration status on GFR measured by these two methods in a group of dogs with suspected renal disease. Eleven dogs were recruited. All dogs underwent standardized scintigraphic examinations before and after 15 ml/kg of fluid was administered intravenously at 5-7 ml/kg/min. Individual kidney GFR estimates (n = 22) were calculated using both methods and a consensus of two observers who were unaware of clinical findings. Individual kidney GFR increased significantly (P = 0.0008) after fluid administration using the integral method and individual kidney GFR using the plasma volume method remained constant. Percentage differences for individual kidney GFR before and after fluid administration were 31.4 +/- 58.1% (change +/- 95% CI) for the integral method and 0.1 +/- 70% (change +/- 95% CI) for the plasma volume method. Intravenously administered fluid increased individual kidney GFR from low to normal in 10 of 22 kidneys using the integral method and in 1 of 22 kidneys using the plasma volume method. Findings supported the use of the plasma volume method for scintigraphic calculation of GFR in dogs with suspected renal disease and indicated that errors of kidney status classification may more likely occur when the integral method is used.
引用
收藏
页码:632 / 637
页数:6
相关论文
共 29 条
[1]   CLINICAL APPLICATION OF PATLAK PLOT CT-GFR IN ANIMALS WITH UPPER URINARY TRACT DISEASE [J].
Alexander, Kate ;
Dunn, Marilyn ;
Carmel, Eric Norman ;
Lavoie, Jean-Pierre ;
del Castillo, Jerome R. E. .
VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (04) :421-427
[2]  
Barrat TMCC, 1975, CLIN ASSESSMENT RENA
[3]   Comparison between the scintigraphic uptake and plasma clearance of 99mTc-diethylenetriaminepentacetic acid (DTPA) for the evaluation of the glomerular filtration rate in dogs [J].
Barthez, PY ;
Hornof, WJ ;
Cowgill, LD ;
Neal, LA ;
Mickel, P .
VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (05) :470-474
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
Chew DJ, 2006, FLUID ELECTROLYTE AC
[6]   Renal nuclear medicine: A review [J].
Daniel, GB ;
Mitchell, SK ;
Mawby, D ;
Sackman, JE ;
Schmidt, D .
VETERINARY RADIOLOGY & ULTRASOUND, 1999, 40 (06) :572-587
[7]  
Ettinger SJ., 2010, TXB VET INTERNAL MED
[9]   KIDNEY DEPTH MEASUREMENT AND ITS INFLUENCE ON QUANTITATION OF FUNCTION FROM GAMMA-CAMERA RENOGRAPHY [J].
GRUENEWALD, SM ;
COLLINS, LT ;
FAWDRY, RM .
CLINICAL NUCLEAR MEDICINE, 1985, 10 (06) :398-401
[10]   Single-injection inulin clearance -: a simple method for measuring glomerular filtration rate in dogs [J].
Haller, M ;
Müller, W ;
Binder, H ;
Estelberger, W ;
Arnold, P .
RESEARCH IN VETERINARY SCIENCE, 1998, 64 (02) :151-156