Comparing the Speech Perception of Cochlear Implant Users with Three Different Finnish Speech Intelligibility Tests in Noise

被引:6
作者
Willberg, Tytti [1 ,2 ]
Sivonen, Ville [3 ,4 ]
Linder, Pia [5 ]
Dietz, Aarno [5 ]
机构
[1] Turku Univ Hosp, Dept Otorhinolaryngol, Turku 20521, Finland
[2] Univ Eastern Finland, Inst Clin Med, Kuopio 70211, Finland
[3] Helsinki Univ Hosp, Head & Neck Ctr, Dept Otorhinolaryngol Head & Neck Surg, Helsinki 00029, Finland
[4] Univ Helsinki, Helsinki 00029, Finland
[5] Kuopio Univ Hosp, Dept Otorhinolaryngol, Kuopio 70029, Finland
基金
芬兰科学院;
关键词
speech perception; speech perception in noise; cochlear implant; matrix sentence test; digit triplet test; outcomes; adult; hearing loss; audiology; MATRIX SENTENCE TEST; RECOGNITION ABILITIES; NORMAL-HEARING; BKB-SIN; VALIDATION; DIGITS; AGE; RELIABILITY; THRESHOLD; LISTENERS;
D O I
10.3390/jcm10163666
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A large number of different speech-in-noise (SIN) tests are available for testing cochlear implant (CI) recipients, but few studies have compared the different tests in the same patient population to assess how well their results correlate. Methods: A clinically representative group of 80 CI users conducted the Finnish versions of the matrix sentence test, the simplified matrix sentence test, and the digit triplet test. The results were analyzed for correlations between the different tests and for differences among the participants, including age and device modality. Results: Strong and statistically significant correlations were observed between all of the tests. No floor or ceiling effects were observed with any of the tests when using the adaptive test procedure. Age or the length of device use showed no correlation to SIN perception, but bilateral CI users showed slightly better results in comparison to unilateral or bimodal users. Conclusions: Three SIN tests that differ in length and complexity of the test material provided comparable results in a diverse CI user group.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Optimizing the perception of soft speech and speech in noise with the Advanced Bionics cochlear implant system
    Holden, Laura K.
    Reeder, Ruth M.
    Firszt, Jill B.
    Finley, Charles C.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2011, 50 (04) : 255 - 269
  • [32] Comparing Sound-Field Speech-Auditory Brainstem Response Components between Cochlear Implant Users with Different Speech Recognition in Noise Scores
    Jarollahi, Farnoush
    Valadbeigi, Ayub
    Jalaei, Bahram
    Maarefvand, Mohammad
    Motasaddi Zarandy, Masoud
    Haghani, Hamid
    Shirzhiyzn, Zahra
    IRANIAN JOURNAL OF CHILD NEUROLOGY, 2022, 16 (02) : 93 - 105
  • [33] Effect of Noise Reduction Gain Errors on Simulated Cochlear Implant Speech Intelligibility
    Kressner, Abigail A.
    May, Tobias
    Dau, Torsten
    TRENDS IN HEARING, 2019, 23
  • [34] Comparison of Speech Recognition in Cochlear Implant Users with Different Speech Processors
    Canina Pinheiro, Maria Madalena
    Mancini, Patricia Cotta
    Soares, Alexandra Dezani
    Ribas, Angela
    Lima, Danielle Penna
    Cavadas, Marcia
    Banhara, Marcos Roberto
    da Silva Carvalho, Sirley Alves
    Buzo, Byanka Cagnacci
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2021, 32 (07) : 469 - 476
  • [35] Predicting Speech Recognition Using the Speech Intelligibility Index and Other Variables for Cochlear Implant Users
    Lee, Sungmin
    Mendel, Lisa Lucks
    Bidelman, Gavin M.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2019, 62 (05): : 1517 - 1531
  • [36] Effect of adaptive beamforming and noise reduction algorithms on speech intelligibility and noise tolerance in bimodal cochlear implant users
    Michels, Anne
    Oukheira, Yassine
    Brendel, Martina
    Aschendorff, Antje
    Arndt, Susan
    Wesarg, Thomas
    COCHLEAR IMPLANTS INTERNATIONAL, 2022, 23 (03) : 148 - 157
  • [37] Effects of a transient noise reduction algorithm on speech intelligibility in noise, noise tolerance and perceived annoyance in cochlear implant users
    Dingemanse, J. Gertjan
    Vroegop, Jantien L.
    Goedegebure, Andre
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2018, 57 (05) : 360 - 369
  • [38] Event-related potentials for better speech perception in noise by cochlear implant users
    Soshi, Takahiro
    Hisanaga, Satoko
    Kodama, Narihiro
    Kanekama, Yori
    Samejima, Yasuhiro
    Yumoto, Eiji
    Sekiyama, Kaoru
    HEARING RESEARCH, 2014, 316 : 110 - 121
  • [39] Long-term Speech Perception in Elderly Cochlear Implant Users
    Dillon, Margaret T.
    Buss, Emily
    Adunka, Marcia C.
    King, English R.
    Pillsbury, Harold C., III
    Adunka, Oliver F.
    Buchman, Craig A.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2013, 139 (03) : 279 - 283
  • [40] Pupillometry and perceived listening effort for cochlear implant users-a comparison of three speech-in-noise tests
    Stronks, Hendrik Christiaan
    Jansen, Paula Louisa
    van Deurzen, Robin
    Briaire, Jeroen Johannes
    Frijns, Johan Hubertus Maria
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2025,