Comparing the Speech Perception of Cochlear Implant Users with Three Different Finnish Speech Intelligibility Tests in Noise

被引:6
|
作者
Willberg, Tytti [1 ,2 ]
Sivonen, Ville [3 ,4 ]
Linder, Pia [5 ]
Dietz, Aarno [5 ]
机构
[1] Turku Univ Hosp, Dept Otorhinolaryngol, Turku 20521, Finland
[2] Univ Eastern Finland, Inst Clin Med, Kuopio 70211, Finland
[3] Helsinki Univ Hosp, Head & Neck Ctr, Dept Otorhinolaryngol Head & Neck Surg, Helsinki 00029, Finland
[4] Univ Helsinki, Helsinki 00029, Finland
[5] Kuopio Univ Hosp, Dept Otorhinolaryngol, Kuopio 70029, Finland
基金
芬兰科学院;
关键词
speech perception; speech perception in noise; cochlear implant; matrix sentence test; digit triplet test; outcomes; adult; hearing loss; audiology; MATRIX SENTENCE TEST; RECOGNITION ABILITIES; NORMAL-HEARING; BKB-SIN; VALIDATION; DIGITS; AGE; RELIABILITY; THRESHOLD; LISTENERS;
D O I
10.3390/jcm10163666
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A large number of different speech-in-noise (SIN) tests are available for testing cochlear implant (CI) recipients, but few studies have compared the different tests in the same patient population to assess how well their results correlate. Methods: A clinically representative group of 80 CI users conducted the Finnish versions of the matrix sentence test, the simplified matrix sentence test, and the digit triplet test. The results were analyzed for correlations between the different tests and for differences among the participants, including age and device modality. Results: Strong and statistically significant correlations were observed between all of the tests. No floor or ceiling effects were observed with any of the tests when using the adaptive test procedure. Age or the length of device use showed no correlation to SIN perception, but bilateral CI users showed slightly better results in comparison to unilateral or bimodal users. Conclusions: Three SIN tests that differ in length and complexity of the test material provided comparable results in a diverse CI user group.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Speech Perception of Elderly Cochlear Implant Users Under Different Noise Conditions
    Hast, Anne
    Schluecker, Luisa
    Digeser, Frank
    Liebscher, Tim
    Hoppe, Ulrich
    OTOLOGY & NEUROTOLOGY, 2015, 36 (10) : 1638 - 1643
  • [2] Music perception and speech intelligibility in noise performance by Italian-speaking cochlear implant users
    Dincer D'Alessandro, Hilal
    Boyle, Patrick J.
    Portanova, Ginevra
    Mancini, Patrizia
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (08) : 3821 - 3829
  • [3] Ceiling effects for speech perception tests in pediatric cochlear implant users
    Spitzer, Emily R.
    Landsberger, David M.
    Lichtl, Alexandra J.
    Waltzman, Susan B.
    COCHLEAR IMPLANTS INTERNATIONAL, 2024, 25 (01) : 69 - 80
  • [4] Music perception and speech intelligibility in noise performance by Italian-speaking cochlear implant users
    Hilal Dincer D’Alessandro
    Patrick J. Boyle
    Ginevra Portanova
    Patrizia Mancini
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 3821 - 3829
  • [5] Frequency change detection and speech perception in cochlear implant users
    Zhang, Fawen
    Underwood, Gabrielle
    McGuire, Kelli
    Liang, Chun
    Moore, David R.
    Fu, Qian-Jie
    HEARING RESEARCH, 2019, 379 : 12 - 20
  • [6] Speech intelligibility tests in cochlear implant patients
    Mueller-Deile, J.
    HNO, 2009, 57 (06) : 580 - 591
  • [7] Behavioral Measures of Temporal Processing and Speech Perception in Cochlear Implant Users
    Blankenship, Chelsea
    Zhang, Fawen
    Keith, Robert
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2016, 27 (09) : 701 - 713
  • [8] Contribution of speech rate to speech perception in multichannel cochlear implant users
    Iwasaki, S
    Nagura, M
    Ocho, S
    Hoshino, T
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (08) : 718 - 721
  • [9] Impact of Microphone Configuration on Speech Perception of Cochlear Implant Users in Traffic Noise
    Weissgerber, Tobias
    Bandeira, Mariana
    Brendel, Martina
    Stoever, Timo
    Baumann, Uwe
    OTOLOGY & NEUROTOLOGY, 2019, 40 (03) : E198 - E205
  • [10] Head orientation benefit to speech intelligibility in noise for cochlear implant users and in realistic listening conditions
    Grange, Jacques A.
    Culling, John F.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2016, 140 (06) : 4061 - 4072