A technique for 3D in vivo quantification of proton density and magnetization transfer coefficients of knee joint cartilage

被引:31
|
作者
Hohe, J
Faber, S
Stammberger, T
Reiser, M
Englmeier, KH
Eckstein, F
机构
[1] Univ Munich, Inst Anat, Musculoskeletal Res Grp, D-80336 Munich, Germany
[2] GSF Forschungszentrum Umwelt & Gesundheit GMBH, Inst Med Informat & Syst Forsch, D-85764 Oberschleissheim, Germany
[3] Klinikum LMU Munchen Grosshadern, Inst Klin Radiol, D-81377 Munich, Germany
关键词
articular cartilage; proton density; magnetization transfer; magnetic resonance imaging;
D O I
10.1053/joca.1999.0318
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To develop an MR-based method for the in vivo evaluation of the structural composition of articular cartilage. Design: Five sagittal magnetic resonance imaging (MRI) protocols were acquired throughout the knee joint of 15 healthy volunteers and the boundaries of the cartilage segmented from a previously validated sequence with high contrast between cartilage and surrounding tissue. The other sequences were matched to these data, using a 3D least squares fit algorithm to exclude motion artefacts. In this way secondary images were computed that included information about the proton density (interstitial water content) and the magnetization transfer coefficient (macromolecules, collagen). The average signal intensities of the 3D cartilage plates were extracted from these data sets and related to a phantom. Results: The signal intensity data showed a high interindividual variability for the proton density (patella 31%, lateral tibia 36%, medial tibia 29%); the patella displaying higher values than the tibia (P<0.001). There were high correlations between the three plates. The magnetization transfer coefficient also showed high variability (patella 25%, lateral tibia 32%, medial tibia 30%) with the lowest values in the medial tibia (P<0.01) and lower correlations between the plates. The slice-to-slice variation (medial to lateral) ranged from 9% to 24%. Conclusion: An MR-based method has been developed for evaluating the proton density and magnetization transfer of articular cartilage in vivo and observing systematic differences between knee joint cartilage plates. The technique has the potential to supply information about the water content and collagen of articular cartilage, in particular at the early state of osteoarthritic degeneration. (C) 2000 OsteoArthritis Research Society International.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 50 条
  • [21] Comparison of knee joint cartilage thickness in triathletes and physically inactive volunteers -: 3D analysis with magnetic resonance imaging
    Mühlbauer, R
    Eckstein, F
    JOURNAL OF MOLECULAR MEDICINE-JMM, 2000, 78 (07): : B47 - B47
  • [22] Optimization of TGF-β1-transduced chondrocytes for cartilage regeneration in a 3D printed knee joint model
    Ahn, Jiyong
    Kim, Seon Ae
    Kim, Ki Won
    Oh, Joon Hyuck
    Kim, Seok Jung
    PLOS ONE, 2019, 14 (05):
  • [23] Correlation between 3D microstructural and 2D histomorphometric properties of subchondral bone with healthy and degenerative cartilage of the knee joint
    Lahm, Andreas
    Kasch, Richard
    Spank, Heiko
    Erggelet, Christoph
    Esser, Jan
    Merk, Harry
    Mrosek, Eike
    HISTOLOGY AND HISTOPATHOLOGY, 2014, 29 (11) : 1477 - 1488
  • [24] IN-VIVO QUANTIFICATION OF PROTEOGLYCAN SYNTHESIS IN ARTICULAR-CARTILAGE OF DIFFERENT TOPOGRAPHICAL AREAS IN THE MURINE KNEE-JOINT
    VANOSCH, GJVM
    VANDERKRAAN, PM
    VANDENBERG, WB
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (04) : 492 - 499
  • [25] An in vivo subject-specific 3D functional knee joint model using combined MR imaging
    Bailiang Chen
    Tryphon Lambrou
    Amaka C. Offiah
    Pedro A. Gondim Teixeira
    Martin Fry
    Andrew Todd-Pokropek
    International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 741 - 750
  • [26] An in vivo subject-specific 3D functional knee joint model using combined MR imaging
    Chen, Bailiang
    Lambrou, Tryphon
    Offiah, Amaka C.
    Teixeira, Pedro A. Gondim
    Fry, Martin
    Todd-Pokropek, Andrew
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (05) : 741 - 750
  • [27] 3D Quantification of Biological Damage for a 160 MeV Proton Beam
    Tan, Hong Qi
    Ang, Khong Wei
    Bettiol, Andrew Anthony
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 589 - 592
  • [28] Simultaneous 3D quantitative magnetization transfer imaging and susceptibility mapping
    Jang, Albert
    Chan, Kwok-Shing
    Mareyam, Azma
    Stockmann, Jason
    Huang, Susie Yi
    Wang, Nian
    Jang, Hyungseok
    Lee, Hong-Hsi
    Liu, Fang
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [29] 3D Bioprinted Implants for Cartilage Repair in Intervertebral Discs and Knee Menisci
    Perera, Kalindu
    Ivone, Ryan
    Natekin, Evelina
    Wilga, Cheryl. A.
    Shen, Jie
    Menon, Jyothi U.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [30] Flow quantification: An in-vitro and in-vivo validation of a rapid, accurate and reproducible 3D echocardiographic technique
    Kapetanakis, S
    Ho, E
    Turner, SP
    Monaghan, MJ
    HEART, 2006, 92 : I39 - I39