A comparison of three amperometric phenoloxidase-Sonogel-Carbon based biosensors for determination of polyphenols in beers

被引:60
作者
ElKaoutit, Mohammed [1 ]
Naranjo-Rodriguez, Ignacio [1 ]
Temsamani, Khalid Riffi [2 ]
Hernandez-Artiga, Maria P. [1 ]
Bellido-Milla, Dolores [1 ]
Hidalgo-Hidalgo de Cisneros, Jose Luis [1 ]
机构
[1] Univ Cadiz, Fac Ciencias, Dept Quim Anal, Puerto Real 11510, Spain
[2] Univ Abdelmalek Essaadi, Dept Chim, Equipe Rech Electrochim & Syst Interfaciaux, Fac Siences Tetouan, Tetouan, Morocco
关键词
Sonogel-Carbon electrode; phenoloxidase enzymes; amperometric biosensors; lager beers; polyphenols; bioelectrochemical index;
D O I
10.1016/j.foodchem.2008.03.006
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Three phenoloxidases based biosensors were successfully developed using as electrochemical transducer a new type of electrode recently developed by our group: the "Sonogel-Carbon electrode". The employed enzymes were Trametes versicolor laccase (Lac), Mushroom tyrosinase (Tyr), and Horseradish peroxidase (HRP). Immobilization step was accomplished by doping the electrode surface with a mixture of the individual enzyme and Nafion ion exchanger as additive-protective. The biosensor responses, optimized in beer real samples, were evaluated for five individual polyphenols. It was found that the developed biosensors were sensitive to nanomolar concentrations of the tested polyphenols. As example, the limit of detection, sensitivity, and response linear range for caffeic acid for Nafion-Lac/Sonogel-Carbon biosensor were 0.06 mu mol L-1, 99.6 nA mu mol(-1) L, and 0.04-2 mu mol L-1, respectively. The stability and reproducibility of the biosensors were evaluated by applying them directly to beer real samples. It has been demonstrated that the Nafion-Lac/Sonogel-Carbon system is the more stable with a relative standard deviation of 3.3% (n = 10), maintaining 84% of its stable response for at least three weeks. Estimation of polyphenol index in eight lager beers and a comparison of the results with those obtained by a classical method was carried out. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1019 / 1024
页数:6
相关论文
共 30 条
  • [1] Sol-gels and electrochemistry: Research at the intersection
    Collinson, MM
    Howells, AR
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 702A - 709A
  • [2] Study of the responses of a sonogel-carbon electrode towards phenolic compounds
    Cordero-Rando, MD
    Naranjo-Rodríguez, I
    Palacios-Santander, JM
    Cubillana-Aguilera, LM
    Hidalgo-Hidalgo-de-Cisneros, JL
    [J]. ELECTROANALYSIS, 2005, 17 (09) : 806 - 814
  • [3] The Sonogel-Carbon electrode as a sol-gel graphite-based electrode
    Cordero-Rando, MDM
    de Cisneros, JLHH
    Blanco, E
    Naranjo-Rodríguez, I
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (10) : 2423 - 2427
  • [4] Amperometric carbon paste biosensor based on plant tissue for the determination of total flavanol content in beers
    Cummings, EA
    Mailley, P
    Linquette-Mailley, S
    Eggins, BR
    McAdams, ET
    McFadden, S
    [J]. ANALYST, 1998, 123 (10) : 1975 - 1980
  • [5] Cummings EA, 2001, J AM SOC BREW CHEM, V59, P84
  • [6] de Cisneros J. L. Hidalgo-Hidalgo, 2001, Patent number, Patent No. [200100556, P200100556]
  • [7] Determination of flavanols in beers with tissue biosensors
    Eggins, BR
    Hickey, C
    Toft, SA
    Zhou, DM
    [J]. ANALYTICA CHIMICA ACTA, 1997, 347 (03) : 281 - 288
  • [8] The Sonogel-Carbon materials as basis for development of enzyme biosensors for phenols and polyphenols monitoring: A detailed comparative study of three immobilization matrixes
    El Kaoutit, Mohammed
    Naranjo-Rodriguez, Ignacio
    Temsamani, Khalid Riffi
    Hidalgo-Hidalgo de Cisneros, Jose Luis
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) : 2958 - 2966
  • [9] Electrochemical estimation of the polyphenol index in wines using a laccase biosensor
    Gamella, M.
    Campuzano, S.
    Reviejo, A. J.
    Pingarron, J. M.
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (21) : 7960 - 7967
  • [10] LACCASE-BASED BIOSENSOR FOR DETERMINATION OF POLYPHENOLS - DETERMINATION OF CATECHOLS IN TEA
    GHINDILIS, AL
    GAVRILOVA, VP
    YAROPOLOV, AI
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (02) : 127 - 131