Evaluation of formaldehyde emission from different types of wood-based panels and flooring materials using different standard test methods

被引:52
作者
Salem, Mohamed Z. M. [1 ,2 ]
Boehm, Martin [1 ]
Srba, Jaromir [3 ]
Berankova, Jitka [3 ]
机构
[1] Czech Univ Life Sci, Fac Forestry & Wood Sci, Dept Wood Proc, Prague, Czech Republic
[2] Univ Alexandria, Forestry & Wood Technol Dept, Fac Agr EL Shatby, Alexandria, Egypt
[3] Timber Res & Dev Inst, Prague, Czech Republic
关键词
Formaldehyde emission; Formaldehyde content; Wood-based panels; Flooring panels; Formaldehyde test methods; INITIAL EMITTABLE CONCENTRATION; VOLATILE ORGANIC-COMPOUNDS; PARTITION-COEFFICIENTS; PRODUCTS; TEMPERATURE; DIFFUSION; RESIN; TVOC; VOCS;
D O I
10.1016/j.buildenv.2011.09.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, formaldehyde emission (FE) and content (FC) from different types of wood-based panels mainly: particleboard (PB), medium and high density fiberboard (MDF and HDF) and plywood (PLW) and flooring materials [HDF laminate, solid wood, solid bamboo and polyvinyl chloride (PVC)] were measured using different test methods namely; European small-scale chamber (EN 717-1), gas analysis (EN 717-2), the American small-scale chamber (ASTM D 6007-02), and the perforator (EN 120) methods. FE was affected with high significance by board type and thickness of PB (P < 0.0001), but there was no significant effect from the moisture content (MC %) of PB (P = 0.94) and PLW (P = 0.195). The corrected FC values measured EN 120 were declined when the MC % decreased. Furthermore, the liberation of formaldehyde was enhanced by the process of painting when 200 g/m(2) oil-based paint was applied for MDF and HDF. There was a strong positive correlation among the four test methods (R-2 values ranged between 0.88 and 0.94) concerning the formaldehyde values from PB-16 mm, and approximately the same indication of formaldehyde values, as well as similar behavior, were seen for each method. Moreover, the results indicate surprisingly that there was a good correlation between EN 120 and ASTM D 6007-02, with R-2 values of 0.93. The measurements of FE from flooring panels were ranged between 0.003 and 0.125 mg/m(3) and the PVC flooring with UV-curable layer only had emissions ranged between 0.003 and 0.008 mg/m(3) as measured by EN 717-1. Values of the emittable formaldehyde concentrations from most of the products investigated in the present study were below the limits that are mandatory in the Czech Republic. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:86 / 96
页数:11
相关论文
共 50 条
  • [1] Formaldehyde and TVOC emission behavior of laminate flooring by structure of laminate flooring and heating condition
    An, Jae-Yoon
    Kim, Sumin
    Kim, Hyun-Joong
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2011, 187 (1-3) : 44 - 51
  • [2] [Anonymous], 1994, 7172 EN
  • [3] [Anonymous], 1996, 7173 EN
  • [4] [Anonymous], 2001, A1460 JIS
  • [5] [Anonymous], 2003, 312 EN
  • [6] [Anonymous], 2008, D5334 - 08 Standard Test Method for Determination of Thermal Conductivity of Soil and Soft Rock by Thermal Needle Probe Procedure, P8, DOI DOI 10.1520/D5334-08
  • [7] [Anonymous], 1993, 120 EN
  • [8] [Anonymous], 2003, 6221 EN
  • [9] [Anonymous], 1993, 322 EN
  • [10] [Anonymous], 2004, 7171 EN