NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings

被引:60
作者
Mendes, Luciano B. [1 ,2 ,3 ]
Ogink, Nico W. M. [2 ]
Edouard, Nadege [4 ]
van Dooren, Hendrik Jan C. [2 ]
Tinoco, Ilda de Fatima F. [3 ]
Mosquera, Julio [2 ]
机构
[1] Inst Agr & Fisheries Res ILVO, Technol & Food Sci Unit T&V, B-9820 Merelbeke, Belgium
[2] Wageningen UR Livestock Res, NL-6700 AC Wageningen, Netherlands
[3] Univ Fed Vicosa, Dept Agr Engn, BR-36570000 Vicosa, MG, Brazil
[4] INRA AgrocampusOuest, PEGASE UMR1348, F-35590 St Gilles, France
关键词
ventilation rate; CO2 mass balance; dairy barn; open-path laser; photo acoustic spectroscopy; OPEN-PATH FTIR; AMMONIA EMISSIONS; PHOTOACOUSTIC-SPECTROSCOPY; AIR EXCHANGE; LAYING HENS; CO2; DAIRY; BALANCE; HOUSES; VALIDATION;
D O I
10.3390/s150511239
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV) barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost Non-Dispersive Infra-Red (NDIR) sensor for intensive spatial field monitoring of CO2 concentrations in a NV dairy cow house. This was achieved by comparing NDIR sensors with two commonly applied methods, a Photo-Acoustic Spectroscope (PAS) Gas Monitor and an Open-Path laser (OP-laser). First, calibrations for the NDIR sensors were obtained in the laboratory. Then, the NDIR sensors were placed in a dairy cow barn for comparison with the PAS and OP-laser methods. The main conclusions were: (a) in order to represent the overall barn CO2 concentration of the dairy cow barn, the number of NDIR sensors to be accounted for average concentration calculation was dependent on barn length and on barn area occupation; and (b) the NDIR CO2 sensors are suitable for multi-point monitoring of CO2 concentrations in NV livestock barns, being a feasible alternative for the PAS and the OP-laser methods to monitor single-point or averaged spatial CO2 concentrations in livestock barns.
引用
收藏
页码:11239 / 11257
页数:19
相关论文
共 43 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
[Anonymous], P 9 INT LIV ENV S AS
[3]   Ventilation flow in pig houses measured and calculated by carbon dioxide, moisture and heat balance equations [J].
Blanes, V ;
Pedersen, S .
BIOSYSTEMS ENGINEERING, 2005, 92 (04) :483-493
[4]   Suitability Evaluation of Multipoint Simultaneous CO2 Sampling Wireless Sensors for Livestock Buildings [J].
Calvet, Salvador ;
Carlos Campelo, Jose ;
Estelles, Fernando ;
Perles, Angel ;
Mercado, Ricardo ;
Jose Serrano, Juan .
SENSORS, 2014, 14 (06) :10479-10496
[5]   Measuring gas emissions from livestock buildings: A review on uncertainty analysis and error sources [J].
Calvet, Salvador ;
Gates, Richard S. ;
Zhang, GuoQiang ;
Estelles, Fernando ;
Ogink, Nico W. M. ;
Pedersen, Soren ;
Berckmans, Daniel .
BIOSYSTEMS ENGINEERING, 2013, 116 (03) :221-231
[6]   Do methane measurements from a laser detector and an indirect open-circuit respiration calorimetric chamber agree sufficiently closely? [J].
Chagunda, M. G. G. ;
Yan, T. .
ANIMAL FEED SCIENCE AND TECHNOLOGY, 2011, 165 (1-2) :8-14
[7]   Ammonia emission and performance of laying hens as affected by different dosages of Yucca schidigera in the diet [J].
Chepete, H. J. ;
Xin, H. ;
Mendes, L. B. ;
Li, H. ;
Bailey, T. B. .
JOURNAL OF APPLIED POULTRY RESEARCH, 2012, 21 (03) :522-530
[8]  
Christensen J, 1990, OPTICAL FILTERS THEI
[9]  
CIGR, 2006, AN HOUS HOT CLIM MUL
[10]   Validation of ventilation rate measurement methods and the ammonia emission from naturally ventilated dairy and beef buildings in the United Kingdom [J].
Demmers, TGM ;
Phillips, VR ;
Short, LS ;
Burgess, LR ;
Hoxey, RP ;
Wathes, CM .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 2001, 79 (01) :107-116