Women's features and inter-/intra-rater agreement on mammographic density assessment in full-field digital mammograms (DDM-SPAIN)

被引:13
|
作者
Perez-Gomez, Beatriz [1 ,2 ]
Ruiz, Franciso [3 ]
Martinez, Inmaculada [3 ]
Casals, Maria [3 ]
Miranda, Josefa [3 ,4 ]
Sanchez-Contador, Carmen [5 ]
Vidal, Carmen [6 ]
Llobet, Rafael [7 ]
Pollan, Marina [1 ,2 ]
Salas, Dolores [3 ,4 ]
机构
[1] Inst Salud Carlos III, Natl Ctr Epidemiol, Canc & Environm Epidemiol Unit, Madrid 28029, Spain
[2] Consortium Biomed Res Epidemiol & Publ Hlth CIBER, Madrid, Spain
[3] Gen Directorate Publ Hlth, Breast Canc Screening Programme, Valencia, Spain
[4] CSISP, Valencia, Spain
[5] Reg Author Hlth & Consumer Affairs, Balear Isl Breast Canc Screening Programme, Hlth Promot Women & Childhood Gen Directorate Pub, Balearic Isl, Spain
[6] Catalan Inst Oncol ICO, Canc Prevent & Control Unit, Barcelona, Spain
[7] Univ Politecn Valencia, E-46071 Valencia, Spain
关键词
Mammographic density; Digital mammograms; Agreement; Kappa; Rater; Risk factors; SCREEN-FILM MAMMOGRAPHY; BREAST-CANCER RISK; DATA SYSTEM; WEIGHTED KAPPA; REPRODUCIBILITY; ACCURACY; CLASSIFICATION; HERITABILITY; DISAGREEMENT; COEFFICIENT;
D O I
10.1007/s10549-011-1833-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Measurement of mammographic density (MD), one of the leading risk factors for breast cancer, still relies on subjective assessment. However, the consistency of MD measurement in full-digital mammograms has yet to be evaluated. We studied inter- and intra-rater agreement with respect to estimation of breast density in full-digital mammograms, and tested whether any of the women's characteristics might have some influence on them. After an initial training period, three experienced radiologists estimated MD using Boyd scale in a left breast cranio-caudal mammogram of 1,431 women, recruited at three Spanish screening centres. A subgroup of 50 randomly selected images was read twice to estimate short-term intra-rater agreement. In addition, a reading of 1,428 of the images, performed 2 years before by one rater, was used to estimate long-term intra-rater agreement. Pair-wise weighted kappas with 95% bootstrap confidence intervals were calculated. Dichotomous variables were defined to identify mammograms in which any rater disagreed with other raters or with his/her own assessment, respectively. The association between disagreement and women's characteristics was tested using multivariate mixed logistic models, including centre as a random-effects term, and taking into account repeated measures when required. All quadratic-weighted kappa values for inter- and intra-rater agreement were excellent (higher than 0.80). None of the studied women's features, i.e. body mass index, brassiere size, menopause, nulliparity, lactation or current hormonal therapy, was associated with higher risk of inter- or intra-rater disagreement. However, raters differed significantly more in images that were classified in the higher-density MD categories, and disagreement in intra-rater assessment was also lower in low-density mammograms. The reliability of MD assessment in full-field digital mammograms is comparable to that for original or digitised images. The reassuring lack of association between subjects' MD-related characteristics and agreement suggests that bias from this source is unlikely.
引用
收藏
页码:287 / 295
页数:9
相关论文
共 1 条
  • [1] Women’s features and inter-/intra-rater agreement on mammographic density assessment in full-field digital mammograms (DDM-SPAIN)
    Beatriz Pérez-Gómez
    Franciso Ruiz
    Inmaculada Martínez
    María Casals
    Josefa Miranda
    Carmen Sánchez-Contador
    Carmen Vidal
    Rafael Llobet
    Marina Pollán
    Dolores Salas
    Breast Cancer Research and Treatment, 2012, 132 : 287 - 295