Study of the IMRT interplay effect using a 4DCT Monte Carlo dose calculation

被引:10
|
作者
Jensen, Michael D. [1 ]
Abdellatif, Ady [2 ]
Chen, Jeff [1 ,2 ,3 ]
Wong, Eugene [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[2] London Hlth Sci Ctr, London Reg Canc Program, Dept Phys & Engn, London, ON, Canada
[3] Univ Western Ontario, Dept Oncol, London, ON, Canada
[4] Univ Western Ontario, Dept Phys & Astron, London, ON, Canada
关键词
DEFORMABLE IMAGE REGISTRATION; INTRA-FRACTION MOTION; QUALITY-ASSURANCE; VERIFICATION; MANAGEMENT; DOSIMETRY; DELIVERY; BEAM;
D O I
10.1088/0031-9155/57/8/N89
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion may lead to dose errors when treating thoracic and abdominal tumours with radiotherapy. The interplay between complex multileaf collimator patterns and patient respiratory motion could result in unintuitive dose changes. We have developed a treatment reconstruction simulation computer code that accounts for interplay effects by combining multileaf collimator controller log files, respiratory trace log files, 4DCT images and a Monte Carlo dose calculator. Two three-dimensional (3D) IMRT step-and-shoot plans, a concave target and integrated boost were delivered to a 1D rigid motion phantom. Three sets of experiments were performed with 100%, 50% and 25% duty cycle gating. The log files were collected, and five simulation types were performed on each data set: continuous isocentre shift, discrete isocentre shift, 4DCT, 4DCT delivery average and 4DCT plan average. Analysis was performed using 3D gamma analysis with passing criteria of 2%, 2 mm. The simulation framework was able to demonstrate that a single fraction of the integrated boost plan was more sensitive to interplay effects than the concave target. Gating was shown to reduce the interplay effects. We have developed a 4DCT Monte Carlo simulation method that accounts for IMRT interplay effects with respiratory motion by utilizing delivery log files.
引用
收藏
页码:N89 / N99
页数:11
相关论文
共 50 条
  • [1] A study of the interplay effect in radiation therapy using a Monte-Carlo model
    Leste, Jeremy
    Medjahed, Imene
    Chauvin, Maxime
    Younes, Tony
    Vieillevigne, Laure
    Ferrand, Regis
    Franceries, Xavier
    Bardies, Manuel
    Simon, Luc
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 73 - 82
  • [2] Dose calculation of dynamic trajectory radiotherapy using Monte Carlo
    Manser, Peter
    Frauchiger, Daniel
    Frei, Daniel
    Volken, Werner
    Terribilini, Dario
    Fix, Michael K.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (01): : 31 - 38
  • [3] Measurement-based Monte Carlo dose calculation system for IMRT pretreatment and on-line transit dose verifications
    Lin, Mu-Han
    Chao, Tsi-Chian
    Lee, Chung-Chi
    Tung, Chuan-Jong
    Yeh, Chie-Yi
    Hong, Ji-Hong
    MEDICAL PHYSICS, 2009, 36 (04) : 1167 - 1175
  • [4] Statistical breathing curve sampling to quantify interplay effects of moving lung tumors in a 4D Monte Carlo dose calculation framework
    von Muenchow, Asmus
    Straub, Katrin
    Losert, Christoph
    Shpani, Roel
    Hofmaier, Jan
    Freislederer, Philipp
    Heinz, Christian
    Thieke, Christian
    Sohn, Matthias
    Alber, Markus
    Floca, Ralf
    Belka, Claus
    Parodi, Katia
    Reiner, Michael
    Kamp, Florian
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 101 : 104 - 111
  • [5] Position-probability-sampled Monte Carlo calculation of VMAT, 3DCRT, step-shoot IMRT, and helical tomotherapy dose distributions using BEAMnrc/DOSXYZnrc
    Belec, Jason
    Ploquin, Nicolas
    La Russa, Daniel J.
    Clark, Brenda G.
    MEDICAL PHYSICS, 2011, 38 (02) : 948 - 960
  • [6] A feasibility study for in vivo treatment verification of IMRT using Monte Carlo dose calculation and deep learning-based modelling of EPID detector response
    Zhang, Jun
    Cheng, Zhibiao
    Fan, Ziting
    Zhang, Qilin
    Zhang, Xile
    Yang, Ruijie
    Wen, Junhai
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [7] Monte Carlo Dose Calculation - A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions
    Lin, Teh
    Wang, Lu
    Ma, C-M Charlie
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 99 - 104
  • [8] Validation of fluence-based 3D IMRT dose reconstruction on a heterogeneous anthropomorphic phantom using Monte Carlo simulation
    Nakaguchi, Yuji
    Ono, Takeshi
    Maruyama, Masato
    Nagasue, Nozomu
    Shimohigashi, Yoshinobu
    Kai, Yudai
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 264 - 272
  • [9] An evaluation of calculation parameters in the EGSnrc/BEAMnrc Monte Carlo codes and their effect on surface dose calculation
    Kim, Jung-Ha
    Hill, Robin
    Kuncic, Zdenka
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (14) : N267 - N278
  • [10] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beams
    Hu, Ye Angela
    Song, Haijun
    Chen, Zhe
    Zhou, Sumin
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03): : 1 - 15