Evaluation of loop-mediated isothermal amplification method (LAMP) for pathogenic Leptospira spp. detection with leptospires isolation and real-time PCR

被引:11
|
作者
Suwancharoen, Duangjai [1 ]
Sittiwicheanwong, Busara [1 ]
Wiratsudakul, Anuwat [2 ,3 ]
机构
[1] Natl Inst Anim Hlth, Dept Livestock Dev, 50-2 Kasetklang, Bangkok 10900, Thailand
[2] Mahidol Univ, Fac Vet Sci, Dept Clin Sci & Publ Hlth, 999 Phuttamonthon Sai4 Rd, Phuttamonthon 73170, Nakhon Pathom, Thailand
[3] Mahidol Univ, Fac Vet Sci, Monitoring & Surveillance Ctr Zoonot Dis Wildlife, 999 Phuttamonthon Sai4 Rd, Phuttamonthon 73170, Nakhon Pathom, Thailand
关键词
accuracy; cattle; LAMP; leptospirosis; urine; DIAGNOSIS; LIPOPROTEIN; LIPL32; PHILIPPINES; CULTURE; SOIL;
D O I
10.1292/jvms.15-0702
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Leptospirosis has been one of the worldwide zoonotic diseases caused by pathogenic Leptospira spp. Many molecular techniques have consecutively been developed to detect such pathogen including loop mediated isothermal amplification method (LAMP). The objectives of this study were to evaluate the diagnostic accuracy of LAMP assay and real-time PCR using bacterial culture as the gold standard and to assess the agreement among these three tests using Cohen's kappa statistics. In total, 533 urine samples were collected from 266 beef and 267 dairy cattle reared in central region of Thailand. Sensitivity and specificity of LAMP were 96.8% (95% CI 81.5-99.8) and 97.0% (95% CI 94.9-98.2), respectively. The accuracy of LAMP (97.0%) was significantly higher than that of real-time PCR (91.9%) at 95% CI. With Cohen's kappa statistics, culture method and LAMP were substantially agreed with each other (77.4%), whereas real-time PCR only moderately agreed with culture (47.7%) and LAMP (45.3%), respectively. Consequently, LAMP was more effective than real-time PCR in detecting Leptospira spp. in the urine of cattle. Besides, LAMP had less cost and was simpler than real-time PCR. Thus, LAMP was an excellent alternative for routine surveillance of leptospirosis in cattle.
引用
收藏
页码:1299 / 1302
页数:4
相关论文
共 50 条
  • [31] Development and evaluation of a loop-mediated isothermal amplification (LAMP) technique for rapid, accurate, and specific detection of Blastocystis spp. in AIDS patients
    Ebrahim Badparva
    Amirreza Javadi Mamaghani
    Farnaz Kheirandish
    Farzad Ebrahimzadeh
    Shirzad Fallahi
    Infection, 2022, 50 : 1295 - 1302
  • [32] Real-Time and Rapid Detection of Phytopythium vexans Using Loop-Mediated Isothermal Amplification Assay
    Ghimire, Bhawana
    Avin, Farhat A.
    Waliullah, Sumyya
    Ali, Emran
    Baysal-Gurel, Fulya
    PLANT DISEASE, 2023, 107 (11) : 3394 - 3402
  • [33] Validation of a Commercial Loop-Mediated Isothermal Amplification (LAMP) Assay for the Rapid Detection of Anisakis spp. DNA in Processed Fish Products
    Cammilleri, Gaetano
    Ferrantelli, Vincenzo
    Pulvirenti, Andrea
    Drago, Chiara
    Stampone, Giuseppe
    Quintero Macias, Gema Del Rocio
    Drago, Sandro
    Arcoleo, Giuseppe
    Costa, Antonella
    Geraci, Francesco
    Di Bella, Calogero
    FOODS, 2020, 9 (01)
  • [34] Colorimetric and Real-Time Loop-Mediated Isothermal Amplification (LAMP) for Detection of Loa loa DNA in Human Blood Samples
    Febrer-Sendra, Begona
    Fernandez-Soto, Pedro
    Crego-Vicente, Beatriz
    Diego, Juan Garcia-Bernalt
    Thuy-Huong Ta-Tang
    Berzosa, Pedro
    Nguema, Rufino
    Ncogo, Policarpo
    Romay-Barja, Maria
    Herrador, Zaida
    Benito, Agustin
    Muro, Antonio
    DIAGNOSTICS, 2022, 12 (05)
  • [35] Loop-Mediated Isothermal Amplification Compared to Real-Time PCR and Enzyme Immunoassay for Toxigenic Clostridium difficile Detection
    Boyanton, Bobby L., Jr.
    Sural, Preethi
    Loomis, Caroline R.
    Pesta, Christine
    Gonzalez-Krellwitz, Laura
    Robinson-Dunn, Barbara
    Riska, Paul
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (03) : 640 - 645
  • [36] Validation of a Commercial Loop-Mediated Isothermal Amplification (LAMP)-Based Kit for the Detection of Salmonella spp. According to ISO 16140:2016
    Di Bella, Calogero
    Costa, Antonella
    Sciortino, Sonia
    Oliveri, Giuseppa
    Cammilleri, Gaetano
    Geraci, Francesco
    Lo Monaco, Daniela
    Carpintieri, Davide
    Lo Bue, Giuseppe
    Bongiorno, Carmelo
    Altomare, Alessandro
    Cipri, Valentina
    Pitti, Rosario
    Lanzillo, Carmine
    Arcoleo, Giuseppe
    Allegro, Rosalinda
    APPLIED SCIENCES-BASEL, 2021, 11 (15):
  • [37] Real-time and visual detection of Cercospora canescens based on the cytb gene using loop-mediated isothermal amplification (LAMP)
    Liu, Zhen
    Zhang, Xinchun
    Chen, Di
    Hou, Jumei
    Liu, Tong
    CANADIAN JOURNAL OF PLANT PATHOLOGY, 2021, 43 (04) : 551 - 558
  • [38] Sensitive Real-Time PCR Detection of Pathogenic Leptospira spp. and a Comparison of Nucleic Acid Amplification Methods for the Diagnosis of Leptospirosis
    Waggoner, Jesse J.
    Balassiano, Ilana
    Abeynayake, Janaki
    Sahoo, Malaya K.
    Mohamed-Hadley, Alisha
    Liu, Yuanyuan
    Vital-Brazil, Juliana Magalhaes
    Pinsky, Benjamin A.
    PLOS ONE, 2014, 9 (11):
  • [39] Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
    Mohamed E. Ahmed
    Mawahib H. Eldigail
    Fatima M. Elamin
    Ibtisam A. Ali
    Martin P. Grobusch
    Imadeldin E. Aradaib
    BMC Veterinary Research, 12
  • [40] Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
    Ahmed, Mohamed E.
    Eldigail, Mawahib H.
    Elamin, Fatima M.
    Ali, Ibtisam A.
    Grobusch, Martin P.
    Aradaib, Imadeldin E.
    BMC VETERINARY RESEARCH, 2016, 12