Evaluation of loop-mediated isothermal amplification method (LAMP) for pathogenic Leptospira spp. detection with leptospires isolation and real-time PCR

被引:11
|
作者
Suwancharoen, Duangjai [1 ]
Sittiwicheanwong, Busara [1 ]
Wiratsudakul, Anuwat [2 ,3 ]
机构
[1] Natl Inst Anim Hlth, Dept Livestock Dev, 50-2 Kasetklang, Bangkok 10900, Thailand
[2] Mahidol Univ, Fac Vet Sci, Dept Clin Sci & Publ Hlth, 999 Phuttamonthon Sai4 Rd, Phuttamonthon 73170, Nakhon Pathom, Thailand
[3] Mahidol Univ, Fac Vet Sci, Monitoring & Surveillance Ctr Zoonot Dis Wildlife, 999 Phuttamonthon Sai4 Rd, Phuttamonthon 73170, Nakhon Pathom, Thailand
来源
JOURNAL OF VETERINARY MEDICAL SCIENCE | 2016年 / 78卷 / 08期
关键词
accuracy; cattle; LAMP; leptospirosis; urine; DIAGNOSIS; LIPOPROTEIN; LIPL32; PHILIPPINES; CULTURE; SOIL;
D O I
10.1292/jvms.15-0702
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Leptospirosis has been one of the worldwide zoonotic diseases caused by pathogenic Leptospira spp. Many molecular techniques have consecutively been developed to detect such pathogen including loop mediated isothermal amplification method (LAMP). The objectives of this study were to evaluate the diagnostic accuracy of LAMP assay and real-time PCR using bacterial culture as the gold standard and to assess the agreement among these three tests using Cohen's kappa statistics. In total, 533 urine samples were collected from 266 beef and 267 dairy cattle reared in central region of Thailand. Sensitivity and specificity of LAMP were 96.8% (95% CI 81.5-99.8) and 97.0% (95% CI 94.9-98.2), respectively. The accuracy of LAMP (97.0%) was significantly higher than that of real-time PCR (91.9%) at 95% CI. With Cohen's kappa statistics, culture method and LAMP were substantially agreed with each other (77.4%), whereas real-time PCR only moderately agreed with culture (47.7%) and LAMP (45.3%), respectively. Consequently, LAMP was more effective than real-time PCR in detecting Leptospira spp. in the urine of cattle. Besides, LAMP had less cost and was simpler than real-time PCR. Thus, LAMP was an excellent alternative for routine surveillance of leptospirosis in cattle.
引用
收藏
页码:1299 / 1302
页数:4
相关论文
共 50 条
  • [1] Development of real-time loop-mediated isothermal amplification (RealAmp) method for sensitive and rapid detection of pathogenic and nonpathogenic Leptospira
    Monica, N. I.
    Rathinasabapathi, P.
    Ramya, M.
    LETTERS IN APPLIED MICROBIOLOGY, 2019, 68 (02) : 196 - 203
  • [2] Application of a loop-mediated isothermal amplification method for the detection of pathogenic Leptospira
    Lin, Xu'ai
    Chen, Yin
    Lu, Yiyu
    Yan, Juying
    Yan, Jie
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 63 (03) : 237 - 242
  • [3] Evaluation of diagnostic accuracy of loop-mediated isothermal amplification method (LAMP) compared with polymerase chain reaction (PCR) for Leptospira spp. in clinical samples: a systematic review and meta-analysis
    Gunasegar, Shan
    Neela, Vasantha Kumari
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2021, 100 (03)
  • [4] Development of Quantitative Real-time PCR and Loop-mediated Isothermal Amplification (LAMP) Assays for Detection of Microsporidium seriolae
    Mekata, Tohru
    Satoh, Jun
    Nakayasu, Chihaya
    Ishii, Yuji
    Harakawa, Shogo
    Kawakami, Hidemasa
    Yanagi, Soetsu
    FISH PATHOLOGY, 2021, 56 (02): : 53 - 61
  • [5] A New Loop-Mediated Isothermal Amplification Method for Rapid, Simple, and Sensitive Detection of Leptospira spp. in Urine
    Koizumi, Nobuo
    Nakajima, Chie
    Harunari, Tsunehito
    Tanikawa, Tsutomu
    Tokiwa, Toshihiro
    Uchimura, Eriko
    Furuya, Tokujiro
    Mingala, Claro Niegos
    Villanueva, Marvin Ardeza
    Ohnishi, Makoto
    Suzuki, Yasuhiko
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (06) : 2072 - 2074
  • [6] Rapid detection of Brucella spp. by the loop-mediated isothermal amplification method
    Ohtsuki, R.
    Kawamoto, K.
    Kato, Y.
    Shah, M. M.
    Ezaki, T.
    Makino, S-I.
    JOURNAL OF APPLIED MICROBIOLOGY, 2008, 104 (06) : 1815 - 1823
  • [7] A nationwide survey of pathogenic leptospires in urine of cattle and buffaloes by Loop-mediated isothermal amplification (LAMP) method in Thailand, 2011-2013
    Suwancharoen, Duangjai
    Limlertvatee, Supaluck
    Chetiyawan, Philaiphon
    Tongpan, Phichet
    Sangkaew, Nongluck
    Sawaddee, Yaowarat
    Inthakan, Kanya
    Wiratsudakul, Anuwat
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2016, 78 (09): : 1495 - 1500
  • [8] Development and evaluation of a loop-mediated isothermal amplification (LAMP) method for Candida glabrata detection
    Yahaya, H.
    Cheah, Y. K.
    Chee, H. Y.
    Than, L. T. L.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2024, 43 (11) : 2211 - 2214
  • [9] Evaluation of the real-time fluorescence loop-mediated isothermal amplification assay for the detection of Ureaplasma urealyticum
    Shen, Jie-Ni
    Ye, Jing-Yi
    Lao, Meng-Xiao
    Wang, Chu-Qiao
    Wu, Dong-Hong
    Chen, Xiao-Ying
    Lin, Li-Hong
    Geng, Wen-Yan
    Guo, Xu-Guang
    AMB EXPRESS, 2022, 12 (01)
  • [10] Comparison of loop-mediated isothermal amplification and real-time PCR for detecting Bordetella pertussis
    Torkaman, Mohammad Reza Allahyar
    Kamachi, Kazunari
    Nikbin, Vajihe Sadat
    Lotfi, Masoumeh Nakhost
    Shahcheraghi, Fereshteh
    JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 64 : 463 - 465