Transmission Line frequency Impedance Characteristic and It's Influence in Transient Protection

被引:0
|
作者
Lei Li [1 ]
Zeng Xiangjun [1 ]
Liu Jianhua [1 ]
Liu Zhengyi [1 ]
Lv Qian [1 ]
Zhang Xiaoli [1 ]
机构
[1] Changsha Univ Sci & Technol, Coll Elect & Informat Engn, Changsha 410076, Hunan, Peoples R China
关键词
Frequency impedance characteristic; transmission line; transient signal; transient protection; fault location;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The transient protection with fault generated high frequency transient signals is a developmental direction of modern power system. It has the advantages: quick fault detection, high precision, no influence by the foundation frequency signal, current transformer saturation and fault resistance. Whereas, the protection is still not applied widely in power systems because the theories about the high frequency transient signal transmission and declining are not very clear. In order to improve it, the frequency impedance characteristics of transmission line are analyzed in the paper. And their effects in the transient protection, especially in traveling wave based fault location are presented. Wavelet packet analysis is then introduced to decompose the fault produced transient signals and remove disturbances, and the wavelet packed analysis based transient protection is simulated. The precision of protection and fault location can be improved.
引用
收藏
页码:1836 / 1840
页数:5
相关论文
共 50 条
  • [31] A constructive method to evaluate the characteristic impedance in a rectangular transmission line
    ESIME Culhuacan, National Polytechnic Institute of México, Mexico
    不详
    Iran. J. Electr. Comput. Eng., 2008, 1 (79-82):
  • [32] CHARACTERISTIC IMPEDANCE OF A CURVED MICROSTRIP TRANSMISSION-LINE - REPLY
    CHOWDHURY, SK
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1990, 3 (05) : 192 - 192
  • [33] A Tunable Transmission Line With Controllable Phase Shifting and Characteristic Impedance
    Ren, Han
    Zhou, Mi
    Gu, Yixin
    Arigong, Bayaner
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2020, 67 (10) : 1720 - 1724
  • [34] CONDITION FOR DISTORTIONLESS TRANSMISSION-LINE WITH A NONUNIFORM CHARACTERISTIC IMPEDANCE
    LUNDSTEDT, J
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1995, 43 (06) : 1386 - 1389
  • [35] CHARACTERISTIC IMPEDANCE OF A CURVED MICROSTRIP TRANSMISSION-LINE - COMMENT
    PRAMANICK, P
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1991, 4 (07) : 283 - 284
  • [36] Characteristic Impedance Analysis of Transmission Lines Considering Frequency Characteristics
    Bai, Hanlin
    Gan, Fan
    Zhang, Nana
    Li, Yunge
    PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 1804 - 1808
  • [37] Transient protection of transmission line using wavelet transform
    Solanki, M
    Song, YH
    Potts, S
    Perks, A
    SEVENTH INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN POWER SYSTEM PROTECTION, 2001, (479): : 299 - 302
  • [38] The Transient Distance Protection on Wind Farm Transmission Line with Crowbar Protection
    Zhang, Xingyu
    Lu, Yuping
    Shi, Dongmin
    PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2017, : 366 - 371
  • [39] HVDC Transmission Line Protection Based on Transient Power
    Tom, Sherin
    Thomas, Jaimol
    1ST GLOBAL COLLOQUIUM ON RECENT ADVANCEMENTS AND EFFECTUAL RESEARCHES IN ENGINEERING, SCIENCE AND TECHNOLOGY - RAEREST 2016, 2016, 25 : 660 - 668
  • [40] Study of removing the influence of microwave reflection in the time domain measurement data of the characteristic impedance of transmission line
    Zhu Jiangmiao
    Li Chaoming
    Miao Jingyuan
    PROCEEDINGS OF 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL. 2, 2015, : 777 - 780