Three-day continuous glucose monitoring for rapid assessment of hypoglycemic events and glycemic variability in type 1 diabetic patients

被引:10
|
作者
Kim, Soo Kyoung [1 ]
Suh, Sunghwan [1 ]
Kim, Mi Yeon [1 ]
Chung, Hye Soo [1 ]
Hur, Kyu Yeon [1 ]
Kim, Sun Wook [1 ]
Chung, Jae Hoon [1 ]
Lee, Myung-Shik [1 ]
Min, Yong-Ki [1 ]
Kim, Kwang-Won [1 ]
Kim, Jae Hyeon [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Div Endocrinol & Metab,Dept Med, Seoul 135710, South Korea
关键词
Continuous glucose monitoring system; Self-monitoring of blood glucose; Type 1 diabetes mellitus; BLOOD-GLUCOSE; MICROVASCULAR COMPLICATIONS; RISK;
D O I
10.1507/endocrj.K10E-378
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was to determine whether glycemic variability is related to hypoglycemic events in type 1 diabetic patients, and whether the hypoglycemic events during a short-term continuous glucose monitoring system (CGMS) period parallel those measured during a 4-week self-monitoring of blood glucose (SMBG) period. We also evaluated whether glycemic variability indexes from a short term CGMS correlate with those from a 4-week SMBG. A total of 49 type I diabetic patients wore CGMS devices for 3 days. These patients also performed SMBG for 4 weeks. Several indexes from the CGMS data were compared with indexes from the SMBG data. Hypoglycemic events (glucose levels <70 mg/dL) that occurred during the 3-day CGMS and 4-week SMBG periods were evaluated and compared. Hypoglycemic events were detected in 33 patients (67%) during the 3-day CGMS period. The patients with hypoglycemic events had a significantly higher glycemic variability index divided by mean glucose of CGMS, and a higher number of hypoglycemic events during the 4-week SMBG, compared to those with non-hypoglycemic events during the 3-day CGMS period. The percentage of hypoglycemic events using the 3-day CGMS was correlated with that from the 4-week SMBG (r = 0.49, P < 0.05) and low blood glucose index (r = 0.51, P < 0.05). The glycemic variability indexes from the 4-week SMBG correlated with the glycemic variability indexes from the 3-day CGMS. The short-term CGMS appears to be clinically useful for rapidly assessing the risk of hypoglycemic events and glycemic variability.
引用
收藏
页码:535 / 541
页数:7
相关论文
共 50 条
  • [31] Association between scanning frequency of flash glucose monitoring and continuous glucose monitoring-derived glycemic makers in children and adolescents with type 1 diabetes
    Suzuki, Junichi
    Urakami, Tatsuhiko
    Yoshida, Kei
    Kuwabara, Remi
    Mine, Yusuke
    Aoki, Masako
    Morioka, Ichiro
    PEDIATRICS INTERNATIONAL, 2021, 63 (02) : 154 - 159
  • [32] Glycemic Variability Determined by Continuous Glucose Monitoring System Predicts Left Ventricular Remodeling in Patients With a First ST-Segment Elevation Myocardial Infarction
    Gohbara, Masaomi
    Iwahashi, Noriaki
    Kataoka, Shunsuke
    Hayakawa, Yoshikazu
    Sakamaki, Kentaro
    Akiyama, Eiichi
    Maejima, Nobuhiko
    Tsukahara, Kengo
    Hibi, Kiyoshi
    Kosuge, Masami
    Ebina, Toshiaki
    Umemura, Satoshi
    Kimura, Kazuo
    CIRCULATION JOURNAL, 2015, 79 (05) : 1092 - 1099
  • [33] Influence of Acute Bouts of Exercise on Blood Glucose in Type 2 Diabetic Patients, as Measured by Continuous Glucose Monitoring Systems
    Bacchi, Elisabetta
    Negri, Carlo
    Bonora, Enzo
    Moghetti, Paolo
    JOURNAL OF DIABETES & METABOLISM, 2013, 4 (08)
  • [34] Influence of Acute Bouts of Exercise on Blood Glucose in Type 2 Diabetic Patients, as Measured by Continuous Glucose Monitoring Systems
    Bacchi, Elisabetta
    Negri, Carlo
    Bonora, Enzo
    Moghetti, Paolo
    JOURNAL OF DIABETES & METABOLISM, 2013, 4 (09)
  • [35] Influence of Acute Bouts of Exercise on Blood Glucose in Type 2 Diabetic Patients, as Measured by Continuous Glucose Monitoring Systems
    Bacchi, Elisabetta
    Negri, Carlo
    Bonora, Enzo
    Moghetti, Paolo
    JOURNAL OF DIABETES & METABOLISM, 2014, 5 (04)
  • [36] Transitioning from Self-Monitoring of Blood Glucose to Continuous Glucose Monitoring in Combination with a mHealth App Improves Glycemic Control in People with Type 1 and Type 2 Diabetes
    Zivkovic, Josip
    Mitter, Michael
    Theodorou, Delphine
    Kober, Johanna
    Mueller-Hoffmann, Wiebke
    Mikulski, Heather
    DIABETES TECHNOLOGY & THERAPEUTICS, 2025, 27 (01) : 10 - 18
  • [37] Glycaemic control in type 2 diabetic patients on chronic haemodialysis: use of a continuous glucose monitoring system
    Riveline, Jean-Pierre
    Teynie, Julie
    Belmouaz, Simohamed
    Franc, Sylvia
    Dardari, Dured
    Bauwens, Marc
    Caudwell, Valerie
    Ragot, Stephanie
    Bridoux, Frank
    Charpentier, Guillaume
    Marechaud, Richard
    Hadjadj, Samy
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2009, 24 (09) : 2866 - 2871
  • [38] Assessment of markers of glycaemic control in diabetic patients with chronic kidney disease using continuous glucose monitoring
    Vos, Frederiek E.
    Schollum, John B.
    Coulter, Carolyn V.
    Manning, Patrick J.
    Duffull, Stephen B.
    Walker, Robert J.
    NEPHROLOGY, 2012, 17 (02) : 182 - 188
  • [39] Glycemic indices of dates "Ramadan Symbolic Food"in patients with type 2 diabetes using continuous glucose monitoring system
    Khalil, Samir Assaad
    Amin, Noha Gaber
    Ibrahim, Atef Mohamed
    Zaky, Doaa Zakaria
    Bishay, Mariam Mounir
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2021, 172
  • [40] Accuracy of Continuous Glucose Monitoring (CGM) during Continuous and High-Intensity Interval Exercise in Patients with Type 1 Diabetes Mellitus
    Moser, Othmar
    Mader, Julia K.
    Tschakert, Gerhard
    Mueller, Alexander
    Groeschl, Werner
    Pieber, Thomas R.
    Koehler, Gerd
    Messerschmidt, Janin
    Hofmann, Peter
    NUTRIENTS, 2016, 8 (08)