A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating

被引:36
|
作者
Badea, Cristian T. [1 ]
Schreibmann, Eduard [2 ]
Fox, Tim [2 ]
机构
[1] Duke Univ, Med Ctr, Ctr In Vivo Microscopy, Durham, NC 27710 USA
[2] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
x-ray; micro-CT; small animal; cardiac; image reconstruction; 4D CT; low dose;
D O I
10.1118/1.2868778
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent advances in murine cardiac studies with three-dimensional cone beam micro-computed tomography (CT) have used either prospective or retrospective gating technique. While prospective gating ensures the best image quality and the highest resolution, it involves longer sampling times and higher radiation dose. Sampling is faster and the radiation dose can be reduced with retrospective gating but the image quality is affected by the limited number of projections with an irregular angular distribution which complicate the reconstruction process, causing significant streaking artifacts. This work involves both prospective and retrospective gating in sampling. Deformable registration is used between a high quality image set acquired with prospective gating with the multiple data sets during the cardiac cycle obtained using retrospective gating. Tests were conducted on a four-dimensional (4D) cardiac mouse phantom and after optimization, the method was applied to in vivo cardiac micro-CT data. Results indicate that, by using our method, the sampling time can be reduced by a factor of 2.5 and the radiation dose can be reduced 35% compared to the prospective sampling while the image quality can be maintained. In conclusion, we proposed a novel solution to 4D cine cardiac micro-CT based on a combined prospective with retrospective gating in sampling and deformable registration post reconstruction that mixed the advantages of both strategies. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1170 / 1179
页数:10
相关论文
共 33 条
  • [31] Estimation of lung motion fields in 4D CT data by variational non-linear intensity-based registration: A comparison and evaluation study
    Werner, Rene
    Schmidt-Richberg, Alexander
    Handels, Heinz
    Ehrhardt, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (15) : 4247 - 4260
  • [32] Evaluation of the Effects of Dose on Lung Ventilation Calculated from 4D-CT using Deformable Image Registration An Application of a Ventilation Calculation Algorithm based on 4D-CT
    Latifi, Kujtim
    Dilling, Thomas J.
    Stevens, Craig W.
    Feygelman, Vladimir
    Moros, Eduardo G.
    Zhang, Geoffrey G.
    BIOIMAGING: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOIMAGING, 2014, : 5 - 11
  • [33] Prediction of mechanical properties of 3D tubular braided composites at different temperatures using a multi-scale modeling framework based on micro-CT
    Zhang, Yuyang
    Li, Huimin
    Liu, Xin
    Chen, Yanhong
    Qin, Chengwei
    Fang, Daining
    COMPOSITES SCIENCE AND TECHNOLOGY, 2024, 245