A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating

被引:36
|
作者
Badea, Cristian T. [1 ]
Schreibmann, Eduard [2 ]
Fox, Tim [2 ]
机构
[1] Duke Univ, Med Ctr, Ctr In Vivo Microscopy, Durham, NC 27710 USA
[2] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
x-ray; micro-CT; small animal; cardiac; image reconstruction; 4D CT; low dose;
D O I
10.1118/1.2868778
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent advances in murine cardiac studies with three-dimensional cone beam micro-computed tomography (CT) have used either prospective or retrospective gating technique. While prospective gating ensures the best image quality and the highest resolution, it involves longer sampling times and higher radiation dose. Sampling is faster and the radiation dose can be reduced with retrospective gating but the image quality is affected by the limited number of projections with an irregular angular distribution which complicate the reconstruction process, causing significant streaking artifacts. This work involves both prospective and retrospective gating in sampling. Deformable registration is used between a high quality image set acquired with prospective gating with the multiple data sets during the cardiac cycle obtained using retrospective gating. Tests were conducted on a four-dimensional (4D) cardiac mouse phantom and after optimization, the method was applied to in vivo cardiac micro-CT data. Results indicate that, by using our method, the sampling time can be reduced by a factor of 2.5 and the radiation dose can be reduced 35% compared to the prospective sampling while the image quality can be maintained. In conclusion, we proposed a novel solution to 4D cine cardiac micro-CT based on a combined prospective with retrospective gating in sampling and deformable registration post reconstruction that mixed the advantages of both strategies. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:1170 / 1179
页数:10
相关论文
共 33 条
  • [21] 3D Visualization and Volume-Based Quantification of Rice Chalkiness In Vivo by Using High Resolution Micro-CT
    Su, Yi
    Xiao, Lang-Tao
    RICE, 2020, 13 (01)
  • [22] Optimising 4D imaging of fast-oscillating structures using X-ray microtomography with retrospective gating
    Klos, Antoine
    Bailly, Lucie
    du Roscoat, Sabine Rolland
    Orgeas, Laurent
    Bernardoni, Nathalie Henrich
    Broche, Ludovic
    King, Andrew
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] Dose Accumulation based on Optimized Motion Field Estimation using Non-Linear Registration in Thoracic 4D CT Image Data
    Werner, R.
    Ehrhardt, J.
    Schmidt-Richberg, A.
    Bodmann, B.
    Cremers, F.
    Handels, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 950 - 953
  • [24] Reducing 4D CT artifacts using optimized sorting based on anatomic similarity
    Johnston, Eric
    Diehn, Maximilian
    Murphy, James D.
    Loo, Billy W., Jr.
    Maxim, Peter G.
    MEDICAL PHYSICS, 2011, 38 (05) : 2424 - 2429
  • [25] Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray
    Cao, Guohua
    Burk, Laurel M.
    Lee, Yueh Z.
    Calderon-Colon, Xiomara
    Sultana, Shabana
    Lu, Jianping
    Zhou, Otto
    MEDICAL PHYSICS, 2010, 37 (10) : 5306 - 5312
  • [26] Evaluation of mesh- and binary-based contour propagation methods in 4D thoracic radiotherapy treatments using patient 4D CT images
    Ma, Yuanyuan
    Liu, Xinguo
    Dai, Zhongying
    He, Pengbo
    Yan, Yuanlin
    Shen, Guosheng
    Yuan, Ping
    Li, Qiang
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 36 : 46 - 53
  • [27] 3D Visualization and Volume-Based Quantification of Rice Chalkiness In Vivo by Using High Resolution Micro-CT
    Yi Su
    Lang-Tao Xiao
    Rice, 2020, 13
  • [28] A NOVEL 4D PDE-BASED APPROACH FOR ACCURATE ASSESSMENT OF MYOCARDIUM FUNCTION USING CINE CARDIAC MAGNETIC RESONANCE IMAGES
    Sliman, Hisham
    Elnakib, Ahmed
    Beache, Garth M.
    Soliman, Ahmed
    Khalifa, Fahmi
    Gimel'farb, Georgy
    Elmaghraby, Adel
    El-Baz, Ayman
    2014 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2014, : 3537 - 3541
  • [29] Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation
    Vedam, S.
    Archambault, L.
    Starkschall, G.
    Mohan, R.
    Beddar, S.
    MEDICAL PHYSICS, 2007, 34 (11) : 4247 - 4255
  • [30] Tracking the evolution of loess microstructure using micro-CT 3D reconstruction based on a soil-particle-aware model
    Zhao, Yuan
    Xu, Ling
    Qin, Chaoyan
    Huang, Xiaolin
    Wu, Yuting
    COMPUTERS AND GEOTECHNICS, 2025, 182