Determination of chloride, chlorate and perchlorate by PDMS microchip electrophoresis with indirect amperometric detection

被引:18
|
作者
Li, Xin-Ai [1 ,2 ]
Zhou, Dong-Mei [2 ]
Xu, Jing-Juan [1 ]
Chen, Hong-Yuan [1 ]
机构
[1] Nanjing Univ, Sch Chem & Chem Engn, Key Lab Analyt Chem Life Sci MOE, Nanjing 210093, Peoples R China
[2] Chinese Acad Sci, Inst Soil Sci, State Key Lab Soil & Sustainable Agr, Nanjing 210008, Peoples R China
基金
中国国家自然科学基金;
关键词
indirect amperometric detection; chlorine-containing anions; poly(dimethylsiloxane); oxygen plasma treatment; microchip capillary electrophoresis; carbon fiber electrode;
D O I
10.1016/j.talanta.2007.10.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, chloride, chlorate and perchlorate are fast separated on PDMS microchip and detected via in-channel indirect amperometric detection mode. With PDMS/PDMS microchip treated by oxygen plasma, anions chloride (Cl-), chlorate (003), and perchlorate (004) are separated within 35 s. Some parameters including buffer salt concentration, buffer pH, separation voltage and detection potential are investigated in detail. The separation conditions using 15 mM (pH 6.12) of 2-(N-morpholino)ethanesulfonic acid (MES) + L-histidine (L-His) as running buffer, -2000 V as separation voltage and 0.7 V as detection potential are optimized. Under this condition, the detection limits of Cl-, ClO3-, and ClO4- are 1.9, 3.6, and 2.8 mu M, respectively. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [1] Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection
    García, CD
    Henry, CS
    ANALYTICA CHIMICA ACTA, 2004, 508 (01) : 1 - 9
  • [2] Microchip Capillary Electrophoresis with Amperometric Detection
    Yurong, Wang
    Hengwu, Chen
    PROGRESS IN CHEMISTRY, 2009, 21 (01) : 200 - 209
  • [3] Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamine detection
    Schöning, MJ
    Jacobs, M
    Muck, A
    Knobbe, DT
    Wang, J
    Chatrathi, M
    Spillmann, S
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2): : 688 - 694
  • [4] In-channel indirect amperometric detection of nonelectroactive anions for electrophoresis on a poly(dimethylsiloxane) microchip
    Xu, JJ
    Peng, Y
    Bao, N
    Xia, XH
    Chen, HY
    ELECTROPHORESIS, 2005, 26 (19) : 3615 - 3621
  • [5] Indirect determination of pyruvic acid by capillary electrophoresis with amperometric detection
    Lu, Xin
    Huang, Wei-Hua
    Ai, Feng
    Wang, Zong-Li
    Cheng, Jie-Ke
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (02): : 347 - 351
  • [6] A capillary electrophoresis microchip for amperometric detection of DNA
    Joo, Gi-Sung
    Jha, Sandeep Kumar
    Kim, Yong-Sang
    CURRENT APPLIED PHYSICS, 2009, 9 (04) : E222 - E224
  • [7] Microchip electrophoresis with amperometric detection for a novel determination of phenolic compounds in olive oil
    del Pilar Godoy-Caballero, Maria
    Isabel Acedo-Valenzuela, Maria
    Galeano-Diaz, Teresa
    Costa-Garcia, Agustin
    Teresa Fernandez-Abedul, Maria
    ANALYST, 2012, 137 (21) : 5153 - 5160
  • [8] DETERMINATION OF A MIXTURE OF CHLORIDE, HYPOCHLORITE, CHLORITE, CHLORATE AND PERCHLORATE IONS BY SHORT-CIRCUIT AMPEROMETRIC TITRATION
    YAMASAKI, S
    OHURA, H
    NAKAMORI, I
    JAPAN ANALYST, 1973, 22 (07): : 843 - 849
  • [9] PDMS Microchip Capillary Electrophoresis for Determination of Thiol Compounds
    Sukanya Viriyatanavirote
    Weena Siangproh
    Orawon Chailapakul
    Journal of Electronic Science and Technology, 2010, 8 (01) : 78 - 81
  • [10] CAPILLARY ELECTROPHORESIS WITH INDIRECT AMPEROMETRIC DETECTION
    OLEFIROWICZ, TM