Effect of Dose Level on Radiologists' Detection of Microcalcifications in Digital Breast Tomosynthesis: An Observer Study with Breast Phantoms

被引:3
|
作者
Chan, Heang-Ping [1 ]
Helvie, Mark A. [1 ]
Klein, Katherine A. [1 ]
McLaughlin, Carol [1 ]
Neal, Colleen H. [1 ]
Oudsema, Rebecca [1 ]
Rahman, W. Tania [1 ]
Roubidoux, Marilyn A. [1 ]
Hadjiiski, Lubomir M. [1 ]
Zhou, Chuan [1 ]
Samala, Ravi K. [1 ]
机构
[1] Univ Michigan, Dept Radiol, 1500 E Med Ctr Dr,Med Inn Bldg C477, Ann Arbor, MI 48109 USA
关键词
Digital breast tomosynthesis; dose; microcalcifications; observer study; COMPUTER-AIDED DETECTION; CLUSTERED MICROCALCIFICATIONS; IMAGE QUALITY; MAMMOGRAPHY; PERFORMANCE; POPULATION; SYSTEM; CLASSIFICATION; CALCIFICATIONS; VISIBILITY;
D O I
10.1016/j.acra.2020.07.038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare radiologists' sensitivity, confidence level, and reading efficiency of detecting microcalcifications in digital breast tomosynthesis (DBT) at two clinically relevant dose levels. Materials and Methods: Six 5-cm-thick heterogeneous breast phantoms embedded with a total of 144 simulated microcalcification clusters of four speck sizes were imaged at two dose modes by a clinical DBT system. The DBT volumes at the two dose levels were read independently by six MQSA radiologists and one fellow with 1-33 years (median 12 years) of experience in a fully-crossed counter-balanced manner. The radiologist located each potential cluster and rated its conspicuity and his/her confidence that the marked location contained a cluster. The differences in the results between the two dose modes were analyzed by two-tailed paired t-test. Results: Compared to the lower-dose mode, the average glandular dose in the higher-dose mode for the 5-cm phantoms increased from 1.34 to 2.07 mGy. The detection sensitivity increased for all speck sizes and significantly for the two smaller sizes (p <0.05). An average of 13.8% fewer false positive clusters was marked. The average conspicuity rating and the radiologists' confidence level were higher for all speck sizes and reached significance (p <0.05) for the three larger sizes. The average reading time per detected cluster reduced significantly (p <0.05) by an average of 13.2%. Conclusion: For a 5-cm-thick breast, an increase in average glandular dose from 1.34 to 2.07 mGy for DBT imaging increased the conspicuity of microcalcifications, improved the detection sensitivity by radiologists, increased their confidence levels, reduced false positive detections, and increased the reading efficiency.
引用
收藏
页码:S42 / S49
页数:8
相关论文
共 50 条
  • [21] Comparison of synthetic and digital mammography with digital breast tomosynthesis or alone for the detection and classification of microcalcifications
    Choi, Ji Soo
    Han, Boo-Kyung
    Ko, Eun Young
    Kim, Ga Ram
    Ko, Eun Sook
    Park, Ko Woon
    EUROPEAN RADIOLOGY, 2019, 29 (01) : 319 - 329
  • [22] Artificial intelligence for breast cancer detection in mammography and digital breast tomosynthesis: State of the art
    Sechopoulos, Ioannis
    Teuwen, Jonas
    Mann, Ritse
    SEMINARS IN CANCER BIOLOGY, 2021, 72 : 214 - 225
  • [23] Model and human observer reproducibility for detecting microcalcifications in digital breast tomosynthesis images
    Petrov, Dimitar
    Marshall, Nicholas
    Young, Kenneth
    Bosmans, Hilde
    MEDICAL IMAGING 2018: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2018, 10577
  • [24] Digital breast tomosynthesis: A pilot observer study
    Good, Walter F.
    Abrams, Gordon S.
    Catullo, Victor J.
    Chough, Denise M.
    Ganott, Marie A.
    Hakim, Christiane M.
    Gur, David
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 865 - 869
  • [25] Digital Breast Tomosynthesis: Observer Performance Study
    Gur, David
    Abrams, Gordon S.
    Chough, Denise M.
    Ganott, Marie A.
    Hakim, Christiane M.
    Perrin, Ronald L.
    Rathfon, Grace Y.
    Sumkin, Jules H.
    Zuley, Margarita L.
    Bandos, Andriy I.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) : 586 - 591
  • [26] Multichannel response analysis on 2D projection views for detection of clustered microcalcifications in digital breast tomosynthesis
    Wei, Jun
    Chan, Heang-Ping
    Hadjiiski, Lubomir M.
    Helvie, Mark A.
    Lu, Yao
    Zhou, Chuan
    Samala, Ravi
    MEDICAL PHYSICS, 2014, 41 (04)
  • [27] Deep-learning convolution neural network for computer-aided detection of microcalcifications in digital breast tomosynthesis
    Samala, Ravi K.
    Chan, Heang-Ping
    Hadjiiski, Lubomir
    Cha, Kenny
    Helvie, Mark A.
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [28] Comparison of Digital Breast Tomosynthesis and Digital Mammography for Detection of Breast Cancer in Kuwaiti Women
    Asbeutah, Akram M.
    Karmani, Nouralhuda
    Asbeutah, AbdulAziz A.
    Echreshzadeh, Yasmin A.
    AlMajran, Abdullah A.
    Al-Khalifah, Khalid H.
    MEDICAL PRINCIPLES AND PRACTICE, 2019, 28 (01) : 10 - 15
  • [29] Diagnostic Performance of Digital Breast Tomosynthesis with the Two-Dimensional Synthesized Mammogram for Suspicious Breast Microcalcifications Compared to Full-Field Digital Mammography in Stereotactic Breast Biopsy
    Shin, Jiwon
    Woo, Ok Hee
    Shin, Hye Seon
    Song, Sung Eun
    Cho, Kyu Ran
    Seo, Bo Kyoung
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2022, 83 (05): : 1090 - 1103
  • [30] Phantoms for quality control procedures in digital breast tomosynthesis: dose assessment
    Bouwman, R. W.
    Diaz, O.
    van Engen, R. E.
    Young, K. C.
    den Heeten, G. J.
    Broeders, M. J. M.
    Veldkamp, W. J. H.
    Dance, D. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13) : 4423 - 4438