Effect of Dose Level on Radiologists' Detection of Microcalcifications in Digital Breast Tomosynthesis: An Observer Study with Breast Phantoms

被引:3
|
作者
Chan, Heang-Ping [1 ]
Helvie, Mark A. [1 ]
Klein, Katherine A. [1 ]
McLaughlin, Carol [1 ]
Neal, Colleen H. [1 ]
Oudsema, Rebecca [1 ]
Rahman, W. Tania [1 ]
Roubidoux, Marilyn A. [1 ]
Hadjiiski, Lubomir M. [1 ]
Zhou, Chuan [1 ]
Samala, Ravi K. [1 ]
机构
[1] Univ Michigan, Dept Radiol, 1500 E Med Ctr Dr,Med Inn Bldg C477, Ann Arbor, MI 48109 USA
关键词
Digital breast tomosynthesis; dose; microcalcifications; observer study; COMPUTER-AIDED DETECTION; CLUSTERED MICROCALCIFICATIONS; IMAGE QUALITY; MAMMOGRAPHY; PERFORMANCE; POPULATION; SYSTEM; CLASSIFICATION; CALCIFICATIONS; VISIBILITY;
D O I
10.1016/j.acra.2020.07.038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare radiologists' sensitivity, confidence level, and reading efficiency of detecting microcalcifications in digital breast tomosynthesis (DBT) at two clinically relevant dose levels. Materials and Methods: Six 5-cm-thick heterogeneous breast phantoms embedded with a total of 144 simulated microcalcification clusters of four speck sizes were imaged at two dose modes by a clinical DBT system. The DBT volumes at the two dose levels were read independently by six MQSA radiologists and one fellow with 1-33 years (median 12 years) of experience in a fully-crossed counter-balanced manner. The radiologist located each potential cluster and rated its conspicuity and his/her confidence that the marked location contained a cluster. The differences in the results between the two dose modes were analyzed by two-tailed paired t-test. Results: Compared to the lower-dose mode, the average glandular dose in the higher-dose mode for the 5-cm phantoms increased from 1.34 to 2.07 mGy. The detection sensitivity increased for all speck sizes and significantly for the two smaller sizes (p <0.05). An average of 13.8% fewer false positive clusters was marked. The average conspicuity rating and the radiologists' confidence level were higher for all speck sizes and reached significance (p <0.05) for the three larger sizes. The average reading time per detected cluster reduced significantly (p <0.05) by an average of 13.2%. Conclusion: For a 5-cm-thick breast, an increase in average glandular dose from 1.34 to 2.07 mGy for DBT imaging increased the conspicuity of microcalcifications, improved the detection sensitivity by radiologists, increased their confidence levels, reduced false positive detections, and increased the reading efficiency.
引用
收藏
页码:S42 / S49
页数:8
相关论文
共 50 条
  • [1] Deep learning denoising of digital breast tomosynthesis: Observer performance study of the effect on detection of microcalcifications in breast phantom images
    Chan, Heang-Ping
    Helvie, Mark A.
    Gao, Mingjie
    Hadjiiski, Lubomir
    Zhou, Chuan
    Garver, Kim
    Klein, Katherine A.
    McLaughlin, Carol
    Oudsema, Rebecca
    Rahman, W. Tania
    Roubidoux, Marilyn A.
    MEDICAL PHYSICS, 2023, 50 (10) : 6177 - 6189
  • [2] The effect of angular dose distribution on the detection of microcalcifications in digital breast tomosynthesis
    Hu, Yue-Houng
    Zhao, Wei
    MEDICAL PHYSICS, 2011, 38 (05) : 2455 - 2466
  • [3] Digital breast tomosynthesis improves diagnostic accuracy of breast microcalcifications
    Liu, Weimin
    Long, Meijun
    Peng, Lingrong
    Qu, Caihong
    Guo, Ruomi
    Kang, Zhuang
    Wang, Jin
    Wu, Juekun
    Wang, Xiaohong
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2021, 31 (02) : 555 - 561
  • [4] Effect of radiologists' experience on breast cancer detection and localization using digital breast tomosynthesis
    Alakhras, Maram M.
    Brennan, Patrick C.
    Rickard, Mary
    Bourne, Roger
    Mello-Thoms, Claudia
    EUROPEAN RADIOLOGY, 2015, 25 (02) : 402 - 409
  • [5] Computer-aided detection of clustered microcalcifications in multiscale bilateral filtering regularized reconstructed digital breast tomosynthesis volume
    Samala, Ravi K.
    Chan, Heang-Ping
    Lu, Yao
    Hadjiiski, Lubomir
    Wei, Jun
    Sahiner, Berkman
    Helvie, Mark A.
    MEDICAL PHYSICS, 2014, 41 (02) : 021901
  • [6] Microcalcifications in the breast and digital tomosynthesis
    Boisserie-Lacroix, Martine
    Ziade, Caroline
    Hurtevent-Labrot, Gabrielle
    Ferron, Stephane
    Depetiteville, Marie-Pierre
    IMAGERIE DE LA FEMME, 2016, 26 (3-4) : 157 - 159
  • [7] Characterization of Breast Masses in Digital Breast Tomosynthesis and Digital Mammograms: An Observer Performance Study
    Chan, Heang-Ping
    Helvie, Mark A.
    Hadjiiski, Lubomir
    Jeffries, Deborah O.
    Klein, Katherine A.
    Neal, Colleen H.
    Noroozian, Mitra
    Paramagul, Chintana
    Roubidoux, Marilyn A.
    ACADEMIC RADIOLOGY, 2017, 24 (11) : 1372 - 1379
  • [8] Digital breast tomosynthesis: computer-aided detection of clustered microcalcifications on planar projection images
    Samala, Ravi K.
    Chan, Heang-Ping
    Lu, Yao
    Hadjiiski, Lubomir M.
    Wei, Jun
    Helvie, Mark A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7457 - 7477
  • [9] Optimizing angular range in digital breast tomosynthesis: A phantom study investigating lesion detection across varied breast density and thickness
    Kim, Hee Jeong
    Kim, Hak Hee
    Eom, Hye Joung
    Choi, Woo Jung
    Chae, Eun Young
    Shin, Hee Jung
    Cha, Joo Hee
    Choi, Young Wook
    Choi, Young Jin
    Kim, Kee Hyun
    Min, Joongkee
    Shim, Woo Hyun
    Lee, Seoyoung
    Cho, Seungryong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 124
  • [10] Multi-domain features for reducing false positives in automated detection of clustered microcalcifications in digital breast tomosynthesis
    Zhang, Fan
    Wu, Shandong
    Zhang, Cheng
    Chen, Qian
    Yang, Xiaodong
    Jiang, Ke
    Zheng, Jian
    MEDICAL PHYSICS, 2019, 46 (03) : 1300 - 1308