Effects of C-factor and resin volume on the bonding to root canal with and without fibre post insertion

被引:39
作者
Aksornmuang, Juthatip [1 ,2 ]
Nakajima, Masatoshi [3 ]
Senawongse, Pisol [4 ]
Tagami, Junji [3 ,5 ]
机构
[1] Prince Songkla Univ, Fac Dent, Dept Prosthet Dent, Hat Yai, Songkhla, Thailand
[2] Prince Songkla Univ, Dent Mat Res Unit, Hat Yai, Songkhla, Thailand
[3] Tokyo Med & Dent Univ, Dept Restorat Sci, Tokyo, Japan
[4] Mahidol Univ, Fac Dent, Dept Operat Dent, Bangkok 10700, Thailand
[5] Tokyo Med & Dent Univ, Global Ctr Excellence Program, Int Res Ctr Mol Sci Tooth & Bone Dis, Tokyo, Japan
关键词
C-Factor; Resin volume; Fibre post; Microtensile bond strength; Root canal; POLYMERIZATION SHRINKAGE STRESS; ENDODONTICALLY TREATED TEETH; CONTRACTION STRESS; CORE MATERIAL; STRENGTH; ADHESIVE; COMPOSITES; SYSTEMS; CONFIGURATION; RESTORATION;
D O I
10.1016/j.jdent.2011.03.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to evaluate the effects of C-factor and resin volume on the regional bond strength of dual-cure luting resin to root canal dentine. Methods: Twelve single-root human premolars were decoronated and post space prepared to a depth of 8 mm, with a diameter of 1.5 mm for six roots and 1.75mm for the other six. Root canal dentine was treated with a dual-cure bonding system and light-cured for 20 s. Specimens were filled with a dual-cure resin composite with or without insertion of 1.4-mm- diameter light-transmitting glass fibre posts, followed by light-curing for 60 s from the coronal direction. After 24 h water storage, each specimen was serially sliced into eight 0.6 mm x 0.6 mm thick beams for a microtensile bond strength test. Failure modes were observed using SEM. Bond strength data were divided into coronal and apical regions and statistically analysed. Results: For both sizes of post space, bond strengths dramatically decreased when fibre posts were inserted. There were no significant differences in microtensile bond strength between 1.5 mm and 1.75mm canal width, regardless of fibre post insertion. Regional differences in bond strength were found only in the resin-filled canals. Conclusions: : The increase of C-factor of the root canal system by insertion of a fibre post had a detrimental effect on the bond strength to root canal dentine. On the other hand, the change of resin volume had no significant effect on bonding. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:422 / 429
页数:8
相关论文
共 35 条
[1]   Resistance to fracture of endodontically treated teeth restored with different post systems [J].
Akkayan, B ;
Gülmez, T .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (04) :431-437
[2]   Regional Bond Strengths and Failure Analysis of Fiber Posts Bonded to Root Canal Dentin [J].
Aksornmuang, J. ;
Nakajima, M. ;
Foxton, R. M. ;
Panyayong, W. ;
Tagami, J. .
OPERATIVE DENTISTRY, 2008, 33 (06) :636-643
[3]  
Aksornmuang J, 2006, AM J DENT, V19, P51
[4]   Regional bond strength of four self-etching primer/adhesive systems to root canal dentin [J].
Aksornmuang, J ;
Nakajima, M ;
Foxton, RM ;
Tagami, J .
DENTAL MATERIALS JOURNAL, 2005, 24 (02) :261-267
[5]   Microtensile bond strength of a dual-cure resin core material to glass and quartz fibre posts [J].
Aksornmuang, J ;
Foxton, RM ;
Nakajima, M ;
Tagami, J .
JOURNAL OF DENTISTRY, 2004, 32 (06) :443-450
[6]   Effect of prolonged photo-irradiation time of three self-etch systems on the bonding to root canal dentine [J].
Aksornmuang, Juthatip ;
Nakajima, Masatoshi ;
Foxton, Richard M. ;
Tagami, Junji .
JOURNAL OF DENTISTRY, 2006, 34 (06) :389-397
[7]   Effects of photocuring strategy on bonding of dual-cure one-step self-etch adhesive to root canal dentin [J].
Aksornmuang, Juthatip ;
Nakajima, Masatoshi ;
Panyayong, Woraphong ;
Tagami, Junji .
DENTAL MATERIALS JOURNAL, 2009, 28 (02) :133-141
[8]   Influence of compliance of the substrate materials on polymerization contraction stress in thin resin composite layers [J].
Alster, D ;
Venhoven, BAM ;
Feilzer, AJ ;
Davidson, CL .
BIOMATERIALS, 1997, 18 (04) :337-341
[9]   The influence of water storage and C-factor on the dentin-resin composite microtensile bond strength and debond pathway utilizing a filled and unfilled adhesive resin [J].
Armstrong, SR ;
Keller, JC ;
Boyer, DB .
DENTAL MATERIALS, 2001, 17 (03) :268-276
[10]   Microtensile bond strength between adhesive cements and root canal dentin [J].
Bouillaguet, S ;
Troesch, S ;
Wataha, JC ;
Krejci, I ;
Meyer, JM ;
Pashley, DH .
DENTAL MATERIALS, 2003, 19 (03) :199-205