The Harris Design-2 total hip replacement fixed with so-called second-generation cementing techniques - A ten to fifteen-year follow-up

被引:25
作者
Bourne, RB [1 ]
Rorabeck, CH [1 ]
Skutek, M [1 ]
Mikkelsen, S [1 ]
Winemaker, M [1 ]
Robertson, D [1 ]
机构
[1] Univ Western Ontario, London Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
D O I
10.2106/00004623-199812000-00007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We analyzed the clinical results of 195 Harris Design-2 total hip replacements performed with so-called second-generation cementing techniques in 166 consecutive patients who had osteoarthrosis. The mean age of the patients at the time of the replacement was sixty-seven years and nine months (range, thirty-one to eighty-nine years). Forty-eight patients (fifty-four hips) died before the time of the latest follow-up, but the implants were apparently functioning well at the time of death. Three patients (four hips) were lost to follow-up. Five patients (five hips; 3 percent) had a revision because of aseptic loosening of the acetabular or femoral component, or both, that was related to wear-induced osteolysis, The mean Harris hip score for the 131 hips that were available at the latest follow-up examination at a mean of twelve years (range, ten to fifteen years) after the operation was 89 +/- 10 points. On the basis of the Harris hip score, seventy-six hips had an excellent result, thirty-four had a good result, fifteen had a fair result, and six had a poor result at the latest follow-up examination. Radiographically, twelve (9 percent) of the 131 acetabular components and three (2 percent) of the 131 femoral components were probably or definitely loose. At a mean of twelve years, 186 (97 percent) of 191 Harris Design-2 implants were in situ or had been in situ at the time of the patient's death.
引用
收藏
页码:1775 / 1780
页数:6
相关论文
共 29 条
  • [1] [Anonymous], 1979, CLIN ORTHOP RELAT RE
  • [2] IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW
    BARRACK, RL
    MULROY, RD
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03): : 385 - 389
  • [3] BOURNE RB, 1984, CLIN ORTHOP RELAT R, V183, P12
  • [4] BOURNE RB, 1990, SURG MUSCULOSKELETAL, V3, P2957
  • [5] ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION
    BROOKER, AF
    BOWERMAN, JW
    ROBINSON, RA
    RILEY, LH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) : 1629 - 1632
  • [6] Charnley J., 1979, LOW FRICTION ARTHROP
  • [7] THE EFFECT OF CENTRIFUGING BONE-CEMENT
    DAVIES, JP
    JASTY, M
    OCONNOR, DO
    BURKE, DW
    HARRIGAN, TP
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (01): : 39 - 42
  • [8] Ritter M A, 1992, J Arthroplasty, V7 Suppl, P365
  • [10] FEMORAL COMPONENT LOOSENING USING CONTEMPORARY TECHNIQUES OF FEMORAL CEMENT FIXATION
    HARRIS, WH
    MCCARTHY, JC
    ONEILL, DA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) : 1063 - 1067