Chemical sensing using an integrated microfluidic system based on the Berthelot reaction

被引:76
作者
Daridon, A [1 ]
Sequeira, M
Pennarun-Thomas, G
Dirac, H
Krog, JP
Gravesen, P
Lichtenberg, J
Diamond, D
Verpoorte, E
de Rooij, NF
机构
[1] Univ Neuchatel, SAMLAB, Inst Microtechnol, CH-2007 Neuchatel, Switzerland
[2] Dublin City Univ, Natl Ctr Sensor Res, Dublin 9, Ireland
[3] Danfoss AS, Corp Technol & Res, DK-6430 Nordborg, Denmark
关键词
microchip; Berthelot reaction; kinetic studies; wastewater;
D O I
10.1016/S0925-4005(01)00573-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Berthelot reaction is a well-established colorimetric method for the determination of ammonia. It has been investigated with the particular aim of incorporating it into a simple, reliable analytical microfluidic sensing system. Absorbance measurements for the complex formed when this reaction is performed in microfluidic chips compare very well to those obtained in a spectrophotometric system. The very high reproducibility and efficiency of mixing by diffusion in the microfluidic chip make it a useful tool for future studies of other chemical methods where kinetics are a limiting factor for the response time. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:235 / 243
页数:9
相关论文
共 38 条
[1]   Hypochlorite ion decomposition: Effects of temperature, ionic strength, and chloride ion [J].
Adam, LC ;
Gordon, G .
INORGANIC CHEMISTRY, 1999, 38 (06) :1299-1304
[2]  
*AM HLTH PUBL ASS, 1980, STAND METH EX WAT WA, V16
[3]  
Berthelot M.P., 1859, Repertoire de Chimice Applique, V1, P284
[4]  
BINZ D, P TRANSD 99 SEND JAP, P684
[5]   Microfabricated silicon mixers for submillisecond quench-flow analysis [J].
Bökenkamp, D ;
Desai, A ;
Yang, X ;
Tai, YC ;
Marzluff, EM ;
Mayo, SL .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :232-236
[6]   SPECTROPHOTOMETRIC DETERMINATION OF AMMONIA AS INDOPHENOL [J].
BOLLETER, WT ;
BUSHMAN, CJ ;
TIDWELL, PW .
ANALYTICAL CHEMISTRY, 1961, 33 (04) :592-&
[7]   Fast mixing by lamination. [J].
Branebjerg, J ;
Gravesen, P ;
Krog, JP ;
Nielsen, CR .
NINTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS, IEEE PROCEEDINGS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND SYSTEMS, 1996, :441-446
[8]   Optimization of photocurable polyurethane membrane composition for ammonium ion sensor [J].
Bratov, A ;
Abramova, N ;
Munoz, J ;
Dominguez, C ;
Alegret, S ;
Batroli, J .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (02) :617-621
[9]  
Daridon A, 2000, MESA MG, P303
[10]   Further studies into the development of a micro-FIA (μFIA) system based on electroosmotic flow for the determination of phosphate as orthophosphate [J].
Doku, GN ;
Haswell, SJ .
ANALYTICA CHIMICA ACTA, 1999, 382 (1-2) :1-13