Zirconia vs. Titanium Dental Implants: Primary Stability In-Vitro Analysis

被引:7
|
作者
Arlucea, Nerea [1 ]
Brizuela-Velasco, Aritza [1 ]
Dieguez-Pereira, Markel [1 ]
Punset, Miquel [2 ,3 ,4 ]
Molmeneu, Meritxell [2 ,4 ]
Sanchez Lasheras, Fernando [5 ,6 ]
deLlanos-Lanchares, Hector [1 ]
Alvarez-Arenal, Angel [1 ]
机构
[1] Univ Oviedo, Sch Dent, Dept Prosthodont & Occlus, C Catedratico Serrano S-N, Oviedo 33006, Spain
[2] Tech Univ Catalonia UPC, Dept Mat Sci & Met, EEBE, Biomat Biomech & Tissue Engn Grp, Barcelona 08034, Spain
[3] Tech Univ Catalonia UPC, UPC Innovat & Technol Ctr CIT UPC, C Jordi Girona 3-1, Barcelona 08034, Spain
[4] Tech Univ Catalonia UPC, Barcelona Res Ctr Multiscale Sci & Engn, Ave Eduard Maristany 10-14, Barcelona 08019, Spain
[5] Univ Oviedo, Dept Math, C Federico Garcia Lorca 18, Oviedo 33007, Spain
[6] Inst Univ Ciencias & Tecnol Espaciales Asturias I, C Independencia 13, Oviedo 33004, Spain
关键词
insertion torque; micromotion; resonance frequency analysis; titanium dental implants; zirconia dental implants; RESONANCE FREQUENCY-ANALYSIS; SURGICAL TECHNIQUE; INSERTION TORQUE; TISSUE RESPONSE; BONE-FORMATION; Y-TZP; OSSEOINTEGRATION; INTERFACE; IMMEDIATE; ABUTMENTS;
D O I
10.3390/ma14247886
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The present experimental trial uses two types of dental implants, one made of titanium (Ti(6)A(l4)V) and the other one of zirconia (ZrO2), but both of identical design, to compare their stability and micro-movements values under load. One of each type of implant (n = 42) was placed into 21 cow ribs, recording the insertion torque and the resonance frequency using a specific transducer. Subsequently, a prosthetic crown made of PMMA was screwed onto each of the implants in the sample. They were then subjected to a static compression load on the vestibular cusp of the crown. The resulting micromovements were measured. The zirconia implants obtained a higher mean of both IT and RFA when compared with those of titanium, with statistically significant differences in both cases (p = 0.0483 and p = 0.0296). However, the micromovement values when load was applied were very similar for both types, with the differences between them (p = 0.3867) not found to be statistically significant. The results show that zirconia implants have higher implant stability values than titanium implants. However, the fact that there are no differences in micromobility values implies that caution should be exercised when applying clinical protocols for zirconia based on RFA, which only has evidence for titanium.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Primary Stability of Trabecular Metal Implant in Comparison to Fully Threaded Implants: In Vitro Study Simulating Immediate Implant Placement
    Magic, Marko
    Zupanek, Gorana
    Lazic, Zoran
    El Chaar, Edgard
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (06) : 584 - 589
  • [42] An In Vitro Evaluation of Primary Stability Values for Two Differently Designed Implants to Suit Immediate Loading in Very Soft Bone
    Krischik, Dirk
    Tokgoz, Selen Ergin
    van Orten, Andreas
    Friedmann, Anton
    Bilhan, Hakan
    DENTISTRY JOURNAL, 2021, 9 (01)
  • [43] Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants
    Elias, Carlos Nelson
    Rocha, Felipe Assis
    Nascimento, Ana Lucia
    Coelho, Paulo Guilherme
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 16 : 169 - 180
  • [44] Can the Bone Density Estimated by CBCT Predict the Primary Stability of Dental Implants? A New Measurement Protocol
    Al-Jamal, Mustafa Faisal J.
    Al-Jumaily, Hassanien A.
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (02) : E171 - E174
  • [45] An in-vitro study of the sterilization of titanium dental implants using low intensity UV-radiation
    Riley, DJ
    Bavastrello, V
    Covani, U
    Barone, A
    Nicolini, C
    DENTAL MATERIALS, 2005, 21 (08) : 756 - 760
  • [46] Sandblasted, acid etched and UV irradiated titanium surface for dental implants: In vitro and in vivo analysis
    Cecilia Cura, Andrea
    Itati Zuchuat, Jesica
    Teresita Tribbia, Liliana
    Eloisa Taravini, Irene Rita
    Alfredo Decco, Oscar
    MATERIALIA, 2022, 21
  • [47] Macrogeometric Differentiation of Dental Implant Primary Stability: An In Vitro Study
    Al-Tarawneh, Sandra K.
    Thalji, Ghadeer
    Cooper, Lyndon F.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1110 - 1118
  • [48] Relevant Aspects of Titanium and Zirconia Dental Implants for Their Fatigue and Osseointegration Behaviors
    Aragoneses, Javier
    Lopez Valverde, Nansi
    Fernandez-Dominguez, Manuel
    Mena-Alvarez, Jesus
    Rodriguez, Cinthia
    Gil, Javier
    Manuel Aragoneses, Juan
    MATERIALS, 2022, 15 (11)
  • [49] In-vitro evaluation of the primary stability of multiple condensing thread designed implants placed by novice and experienced clinicians
    Javed, Fawad
    Lau, Jessica
    Delgado-Ruiz, Rafael
    Romanos, Georgios E.
    SURGERY IN PRACTICE AND SCIENCE, 2020, 2
  • [50] Bone Ingrowth and Initial Stability of Titanium and Porous Tantalum Dental Implants: A Pilot Canine Study
    Kim, Do-Gyoon
    Huja, Sarandeep S.
    Tee, Boon Ching
    Larsen, Peter E.
    Kennedy, Kelly S.
    Chien, Hua-Hong
    Lee, Jin Whan
    Wen, Hai Bo
    IMPLANT DENTISTRY, 2013, 22 (04) : 399 - 405