Potential contact and intraocular lenses based on hydrophilic/hydrophobic sulfonated syndiotactic polystyrene membranes

被引:4
|
作者
Zuppolini, Simona [1 ]
Borriello, Anna [1 ]
Pellegrino, Marina [2 ,3 ]
Venditto, Vincenzo [2 ,3 ]
Ambrosio, Luigi [1 ]
Nicolais, Luigi [4 ]
机构
[1] Natl Res Council Italy, Inst Polymers Composites & Biomat, Naples, Italy
[2] Univ Salerno, Dept Chem & Biol, Salerno, Italy
[3] Univ Salerno, INSTM Res Unit, Salerno, Italy
[4] Univ Naples Federico II, Mat Srl, Campus San Giovanni Teduccio, Naples, Italy
关键词
Sulfonated polystyrene; Nanoporous crystalline structure; Contact lens; Hydrophilic/hydrophobic film; NANOPOROUS-CRYSTALLINE; AMORPHOUS PHASES; CELLULAR GROWTH; ASSAY; PROLIFERATION; SORPTION; FILMS; ORIENTATION; VIABILITY; KINETICS;
D O I
10.1016/j.jksus.2017.09.004
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Crystalline films of syndiotactic polystyrene (s-PS), a commercially available thermoplastic polymer, having a highly hydrophilic amorphous phase, were achieved by using a mild solid-state sulfonation procedure. Despite the used mild process conditions, an easy and uniform sulfonation of the phenyl rings of the amorphous phase is obtained. The crystallinity of the polymer was not affect by the sulfonation degree (S), at least at S less than 20%, and the obtained polymer films show the nanoporous crystalline form of s-PS. As widely reported in literature, the nanoporous nature of the polymer crystalline phase gives to these materials the ability to absorb and release organic molecules of appropriate size and polarity. This property, coupled to transparency, makes these materials potentially useful intraocular lens (IOLs) and contact lens applications. Sulfonation procedure and sulfonated film samples characterization by using wide-angle X-ray diffraction (WAXD), Fourier-transform infrared (FTIR) and ultraviolet-visible (UV-vis) spectroscopy techniques and water sorption tests were reported. Furthermore, the biocompatibility study demonstrated no cytotoxicity and appropriate cell interaction properties for the specific applications. (C) 2017 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 50 条
  • [41] HTA ANALYSIS OF INTRAOCULAR LENSES AFTER CATARACT SURGERY: HYDROPHOBIC VS. HYDROPHILIC LENSES - HEALTH TECHNOLOGY ASSESSMENT IN SLOVAK HEALTHCARE ENVIRONMENT
    Mesaros, T.
    Mesaros, S.
    VALUE IN HEALTH, 2017, 20 (09) : A804 - A804
  • [42] Nanocomposite membranes based on sulfonated polystyrene ethylene butylene polystyrene (SSEBS) and sulfonated SiO2 for microbial fuel cell application
    Sivasankaran, Ayyaru
    Sangeetha, Dharmalingam
    Ahn, Young-Ho
    CHEMICAL ENGINEERING JOURNAL, 2016, 289 : 442 - 451
  • [43] The diffusion and bulk properties of polyurethane (PU)-based hydrophilic and hydrophobic membranes
    Pulat, M
    Akdogan, A
    JOURNAL OF APPLIED POLYMER SCIENCE, 2002, 85 (01) : 193 - 198
  • [44] Syndiotactic polystyrene based ionogel membranes for high temperature lithium-ion batteries
    Raut, Prasad
    Chen, Yu-Ming
    Zhu, Yu
    Jana, Sadhan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [45] In vivo subjective and objective longitudinal chromatic aberration after bilateral implantation of the same design of hydrophobic and hydrophilic intraocular lenses
    Vinas, Maria
    Dorronsoro, Carlos
    Garzon, Nuria
    Poyales, Francisco
    Marcos, Susana
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2115 - 2124
  • [46] Comparing optical quality and simulated defocus curves: head-to-head analysis of hydrophilic and hydrophobic trifocal intraocular lenses
    Labuz, Grzegorz
    Yan, Weijia
    Khoramnia, Ramin
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2025, 51 (02): : 161 - 166
  • [47] Serial opacification of a hydrophilic-hydrophobic acrylic intraocular lens: analysis of potential risk factors
    Scherer, Nicolas C. D.
    Mueller, Karolina
    Prahs, Philipp M.
    Radeck, Viola
    Helbig, Horst
    Maerker, David A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (12): : 1624 - 1629
  • [48] Porous hydrophobic/hydrophilic composite membranes - Application in desalination using direct contact membrane distillation
    Khayet, M
    Mengual, JI
    Matsuura, T
    JOURNAL OF MEMBRANE SCIENCE, 2005, 252 (1-2) : 101 - 113
  • [49] Novel porous composite hydrophobic/hydrophilic polysulfone membranes for desalination by direct contact membrane distillation
    Qtaishat, M.
    Khayet, M.
    Matsuura, T.
    JOURNAL OF MEMBRANE SCIENCE, 2009, 341 (1-2) : 139 - 148
  • [50] INTRAOCULAR PENETRATION OF BACITRACIN AND POLYMIXIN-B AFTER ADMINISTRATION BY MEANS OF HYDROPHILIC GEL CONTACT-LENSES
    BRETTSCHNEIDER, I
    PRAUS, R
    KREJCI, L
    HAVRANEK, M
    OPHTHALMIC RESEARCH, 1975, 7 (04) : 296 - 302