Potential contact and intraocular lenses based on hydrophilic/hydrophobic sulfonated syndiotactic polystyrene membranes

被引:4
|
作者
Zuppolini, Simona [1 ]
Borriello, Anna [1 ]
Pellegrino, Marina [2 ,3 ]
Venditto, Vincenzo [2 ,3 ]
Ambrosio, Luigi [1 ]
Nicolais, Luigi [4 ]
机构
[1] Natl Res Council Italy, Inst Polymers Composites & Biomat, Naples, Italy
[2] Univ Salerno, Dept Chem & Biol, Salerno, Italy
[3] Univ Salerno, INSTM Res Unit, Salerno, Italy
[4] Univ Naples Federico II, Mat Srl, Campus San Giovanni Teduccio, Naples, Italy
关键词
Sulfonated polystyrene; Nanoporous crystalline structure; Contact lens; Hydrophilic/hydrophobic film; NANOPOROUS-CRYSTALLINE; AMORPHOUS PHASES; CELLULAR GROWTH; ASSAY; PROLIFERATION; SORPTION; FILMS; ORIENTATION; VIABILITY; KINETICS;
D O I
10.1016/j.jksus.2017.09.004
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Crystalline films of syndiotactic polystyrene (s-PS), a commercially available thermoplastic polymer, having a highly hydrophilic amorphous phase, were achieved by using a mild solid-state sulfonation procedure. Despite the used mild process conditions, an easy and uniform sulfonation of the phenyl rings of the amorphous phase is obtained. The crystallinity of the polymer was not affect by the sulfonation degree (S), at least at S less than 20%, and the obtained polymer films show the nanoporous crystalline form of s-PS. As widely reported in literature, the nanoporous nature of the polymer crystalline phase gives to these materials the ability to absorb and release organic molecules of appropriate size and polarity. This property, coupled to transparency, makes these materials potentially useful intraocular lens (IOLs) and contact lens applications. Sulfonation procedure and sulfonated film samples characterization by using wide-angle X-ray diffraction (WAXD), Fourier-transform infrared (FTIR) and ultraviolet-visible (UV-vis) spectroscopy techniques and water sorption tests were reported. Furthermore, the biocompatibility study demonstrated no cytotoxicity and appropriate cell interaction properties for the specific applications. (C) 2017 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 50 条
  • [21] Hydrophobic versus hydrophilic acrylic intraocular lenses within public sector based on the type of funding contacts: the debate continues
    Nanavaty, Mayank A.
    EYE, 2023, 37 (18) : 3712 - 3713
  • [22] Hydrophobic versus hydrophilic acrylic intraocular lenses within public sector based on the type of funding contacts: the debate continues
    Mayank A. Nanavaty
    Eye, 2023, 37 : 3712 - 3713
  • [23] Ocular aberrations after cataract surgery with hydrophobic and hydrophilic acrylic intraocular lenses - Comparative study
    Rohart, Charlotte
    Lemarinel, Beatrice
    Hoang-Xuan, Thanh
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (07): : 1201 - 1205
  • [24] On the Proton Conduction Pathways in Polyelectrolyte Membranes Based on Syndiotactic-Polystyrene
    Schiavone, Maria-Maddalena
    Zhao, Yue
    Iwase, Hiroki
    Arima-Osonoi, Hiroshi
    Takata, Shin-ichi
    Radulescu, Aurel
    MEMBRANES, 2022, 12 (02)
  • [25] Porous hydrophobic-hydrophilic composite membranes for direct contact membrane distillation
    Puranik, Aishwarya A.
    Rodrigues, Lydia N.
    Chau, John
    Li, Lin
    Sirkar, Kamalesh K.
    JOURNAL OF MEMBRANE SCIENCE, 2019, 591
  • [26] Posterior capsule opacification rate after phacoemulsification in pediatric cataract: Hydrophilic versus hydrophobic intraocular lenses
    Sen, Pradhnya
    Kshetrapal, Mansi
    Shah, Chintan
    Mohan, Amit
    Jain, Elesh
    Sen, Alok
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1380 - 1385
  • [27] Dual drug delivery from hydrophobic and hydrophilic intraocular lenses: in-vitro and in-vivo studies
    Topete, Ana
    Tang, Junmei
    Ding, Xiaoxu
    Filipe, Helena P.
    Saraiva, Jorge A.
    Serro, Ana Paula
    Lin, Quankui
    Saramago, Benilde
    JOURNAL OF CONTROLLED RELEASE, 2020, 326 : 245 - 255
  • [28] Comparison Study of Anterior Capsule Contraction of Hydrophilic and Hydrophobic Intraocular Lenses Under the Same Size Capsulotomy
    Wang, Yuyan
    Wang, Wei
    Zhu, Yanan
    Xu, Jia
    Luo, Chenqi
    Yao, Ke
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (01):
  • [29] Dual drug delivery from hydrophobic and hydrophilic intraocular lenses: in-vitro and in-vivo studies
    Topete, Ana
    Tang, Junmei
    Ding, Xiaoxu
    Filipe, Helena P.
    Saraiva, Jorge A.
    Serro, Ana Paula
    Lin, Quankui
    Saramago, Benilde
    Journal of Controlled Release, 2020, 326 : 245 - 255
  • [30] MEASUREMENTS OF INTRAOCULAR GENTAMICIN CONCENTRATION USING HYDROPHILIC CONTACT-LENSES AS DRUG DELIVERY SYSTEM
    MESTER, U
    KRASEMANN, C
    STEIN, HJ
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1976, 169 (04) : 492 - 495