Slot harmonic frequency detection as a technique to improve stator current spectrum approach for broken rotor bars fault diagnosis

被引:0
作者
Benouzza, Noureddine [1 ]
Boudinar, Ahmed Hamida [1 ]
Bendiabdellah, Azeddine [1 ]
Khodja, Mohammed [1 ]
机构
[1] Univ Sci & Technol Oran, Fac Elect Engn, Diag Grp, Oran, Algeria
来源
2015 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES & POWER ELECTRONICS (ACEMP), 2015 INTL CONFERENCE ON OPTIMIZATION OF ELECTRICAL & ELECTRONIC EQUIPMENT (OPTIM) & 2015 INTL SYMPOSIUM ON ADVANCED ELECTROMECHANICAL MOTION SYSTEMS (ELECTROMOTION) | 2015年
关键词
Squirrel cage motor; diagnosis; broken bars faults; current spectral analysis; slots harmonic;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present in this paper an overview of the slot harmonic frequency detection applied to the broken rotor bars faults diagnosis This technique uses the behavior of the current spectral analysis and the estimation of the rotor slot harmonic to detect broken rotor bars in three phase induction machine. Experimental tests performed with broken rotor bars show the effectiveness and merits of the proposed technique.