Stochastic rat lung dosimetry for inhaled radon progeny: a surrogate for the human lung for lung cancer risk assessment

被引:5
作者
Winkler-Heil, R. [1 ]
Hussain, M. [1 ,2 ]
Hofmann, W. [1 ]
机构
[1] Salzburg Univ, Dept Mat Res & Phys, Div Phys & Biophys, A-5020 Salzburg, Austria
[2] Higher Educ Commiss Pakistan, Islamabad 44000, Pakistan
关键词
Inhalation; Radon progeny; Rat lung; Lung dosimetry; PARTICLE DEPOSITION PATTERNS; AEROSOL DEPOSITION; MUCOCILIARY CLEARANCE; SIZE DISTRIBUTIONS; MODELS; AIRWAYS; INHALATION; EXPOSURE; VARIABILITY; EPITHELIUM;
D O I
10.1007/s00411-015-0591-8
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Laboratory rats are frequently used in inhalation studies as a surrogate for human exposures. The objective of the present study was therefore to develop a stochastic dosimetry model for inhaled radon progeny in the rat lung, to predict bronchial dose distributions and to compare them with corresponding dose distributions in the human lung. The most significant difference between human and rat lungs is the branching structure of the bronchial tree, which is relatively symmetric in the human lung, but monopodial in the rat lung. Radon progeny aerosol characteristics used in the present study encompass conditions typical for PNNL and COGEMA rat inhalation studies, as well as uranium miners and human indoor exposure conditions. It is shown here that depending on exposure conditions and modeling assumptions, average bronchial doses in the rat lung ranged from 5.4 to 7.3 mGy WLM-1. If plotted as a function of airway generation, bronchial dose distributions exhibit a significant maximum in large bronchial airways. If, however, plotted as a function of airway diameter, then bronchial doses are much more uniformly distributed throughout the bronchial tree. Comparisons between human and rat exposures indicate that rat bronchial doses are slightly higher than human bronchial doses by about a factor of 1.3, while lung doses, averaged over the bronchial (BB), bronchiolar (bb) and alveolar-interstitial (AI) regions, are higher by about a factor of about 1.6. This supports the current view that the rat lung is indeed an appropriate surrogate for the human lung in case of radon-induced lung cancers. Furthermore, airway diameter seems to be a more appropriate morphometric parameter than airway generations to relate bronchial doses to bronchial carcinomas.
引用
收藏
页码:225 / 241
页数:17
相关论文
共 66 条
[21]  
HARLEY NH, 1988, RADIAT PROT DOSIM, V24, P457
[22]   DEPOSITION OF PARTICLES IN THE HUMAN RESPIRATORY-TRACT IN THE SIZE RANGE 0.005-15-MU-M [J].
HEYDER, J ;
GEBHART, J ;
RUDOLF, G ;
SCHILLER, CF ;
STAHLHOFEN, W .
JOURNAL OF AEROSOL SCIENCE, 1986, 17 (05) :811-825
[23]   MONTE-CARLO MODELING OF AEROSOL DEPOSITION IN HUMAN LUNGS .2. DEPOSITION FRACTIONS AND THEIR SENSITIVITY TO PARAMETER VARIATIONS [J].
HOFMANN, W ;
KOBLINGER, L .
JOURNAL OF AEROSOL SCIENCE, 1990, 21 (05) :675-688
[24]   RADON LUNG DOSIMETRY MODELS [J].
Hofmann, W. ;
Winkler-Heil, R. .
RADIATION PROTECTION DOSIMETRY, 2011, 145 (2-3) :206-212
[25]   The effect of lung structure on mucociliary clearance and particle retention in human and rat lungs [J].
Hofmann, W ;
Asgharian, B .
TOXICOLOGICAL SCIENCES, 2003, 73 (02) :448-456
[26]   RADON PROGENY DOSIMETRY IN THE RAT LUNG [J].
HOFMANN, W ;
MENACHE, MG ;
GRAHAM, RC .
HEALTH PHYSICS, 1993, 64 (03) :279-290
[27]   Overview of radon lung dosimetry [J].
Hofmann, W .
RADIATION PROTECTION DOSIMETRY, 1998, 79 (1-4) :229-236
[28]   Characterization of local particle deposition patterns in human and rat lungs by different morphometric parameters [J].
Hofmann, W ;
Bergmann, R ;
Koblinger, L .
JOURNAL OF AEROSOL SCIENCE, 1999, 30 (05) :651-667
[29]   Modeling energy deposition and cellular radiation effects in human bronchial epithelium by radon progeny alpha particles [J].
Hofmann, W ;
Ménache, MG ;
Crawford-Brown, DJ ;
Caswell, RS ;
Karam, LR .
HEALTH PHYSICS, 2000, 78 (04) :377-393
[30]   Modelling inhaled particle deposition in the human lung-A review [J].
Hofmann, Werner .
JOURNAL OF AEROSOL SCIENCE, 2011, 42 (10) :693-724