Validation of the ICP-MS Method for Determination of Trace Elements Provided by ICH Q3D Guideline in Fosamprenavir Calcium

被引:0
作者
Radic, I [1 ]
Runje, M. [1 ]
Cvetnic, M. [2 ]
Haluzan, M. [3 ]
Jelicic, M-L [4 ]
Miloloza, M. [2 ]
Grgic, D. Kucic [2 ]
Prevaric, V [2 ]
Ukic, S. [2 ]
Bolanca, T. [2 ,5 ]
机构
[1] TEVA API Croatia, Pliva Hrvatska Doo, Prudnicka Cesta 54, Zagreb 10000, Croatia
[2] Univ Zagreb, Fac Chem Engn & Technol, Marulicev Trg 19, Zagreb 10000, Croatia
[3] TEVA API Croatia, Pliva Hrvatska Doo, Baruna Filipovica 25, Zagreb 10000, Croatia
[4] Univ Zagreb, Fac Pharm & Biochem, A Kovacica 1, Zagreb 10000, Croatia
[5] Univ North, Trg Dr Zarka Dolinara 1, Koprivnica 48000, Croatia
来源
KEMIJA U INDUSTRIJI-JOURNAL OF CHEMISTS AND CHEMICAL ENGINEERS | 2021年 / 70卷 / 11-12期
关键词
Microwave digestion; ICP-MS; API; fosamprenavir calcium; osmium; HEAVY-METALS; MASS-SPECTROMETRY; IMPURITIES;
D O I
10.15255/KUI.2021.004
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Fosamprenavir calcium is an active pharmaceutical ingredient (API) in which trace elements must be monitored by ICH Q3D Guideline. It delivers appropriate method to ensure the quality of the product and its safe use. Elemental impurities in API are separated in three classes based on their toxicity and probability of their occurrence in the product. ICP-MS has proven to be a suitable technique with the appropriate sample preparation method. Due to the presence of oxidising agents in the sample preparation, determination of osmium is problematic. In the presence of oxidising nitric acid, a highly volatile and toxic osmium tetraoxide is formed. Due to its high volatility, the recovery of osmium has reached the value of 287 %, which exceeds recovery limit (70-150 %). However, osmium can be stabilised by complexation with thiourea in the hydrochloric acid solution (recovery = 87 %). In that way, the loss of osmium is reduced and good results are achieved in terms of usability, accuracy, and precision. A method with addition of thiourea has been successfully validated through main validation parameters: linearity, quantitation limit, selectivity, accuracy, precision (which included repeatability and intralaboratory reproducibility), and robustness. Each of these validation parameters met the acceptance criteria, and therefore it was concluded that the method is suitable for the determination of trace elements in fosamprenavir calcium by ICP-MS.
引用
收藏
页码:701 / 709
页数:9
相关论文
共 18 条
  • [1] [Anonymous], 2014, US PHARMACOPEIAL CON
  • [2] Determination of elemental impurities in pharmaceutical products and related matrices by ICP-based methods: a review
    Barin, Juliano S.
    Mello, Paola A.
    Mesko, Marcia F.
    Duarte, Fabio A.
    Flores, Erico M. M.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (17) : 4547 - 4566
  • [3] European Medicines Agency, 2005, TELZIR EPAR SCI DISC
  • [4] International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use, 2019, ICH HARM GUID GUID H
  • [5] Toxicological overview of impurities in pharmaceutical products
    Jacobson-Kram, David
    McGovern, Timothy
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2007, 59 (01) : 38 - 42
  • [6] ICH Q3D based elemental impurities study in liquid pharmaceutical dosage form with high daily intake - comparative analysis by ICP-OES and ICP-MS
    Janchevska, Katerina
    Stafilov, Trajce
    Memed-Sejfulah, Suzan
    Bogdanoska, Mirjana
    Ugarkovic, Sonja
    Petrushevski, Gjorgji
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2020, 46 (03) : 456 - 461
  • [7] A rapid ICP-MS screen for heavy metals in pharmaceutical compounds
    Lewen, N
    Mathew, S
    Schenkenberger, M
    Raglione, T
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (04) : 739 - 752
  • [8] Strategies to overcome spectral interference in ICP-MS detection
    Lum, Tsz-Shan
    Leung, Kelvin Sze-Yin
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (05) : 1078 - 1088
  • [9] Complex samples and spectral interferences in ICP-MS: Evaluation of tandem mass spectrometry for interference-free determination of cadmium, tin and platinum group elements
    Machado, Raquel C.
    Amaral, Clarice D. B.
    Schiavo, Daniela
    Nobrega, Joaquim A.
    Nogueira, Ana Rita A.
    [J]. MICROCHEMICAL JOURNAL, 2017, 130 : 271 - 275
  • [10] Marczenko Z., 2000, SEPARATION PRECONCEN, V10, P528