Corneal biomechanics measured with the ocular response analyser in patients with unilateral open-angle glaucoma

被引:30
作者
Hirneiss, Christoph [1 ]
Neubauer, Aljoscha S. [1 ]
Yu, Alice [1 ]
Kampik, Anselm [1 ]
Kernt, Marcus [1 ]
机构
[1] Univ Munich, Augenklin, Dept Ophthalmol, Klinikum Univ Munchen, D-80336 Munich, Germany
关键词
corneal hysteresis; ocular response analyser; unilateral glaucoma; INTRAOCULAR-PRESSURE; KERATOCONIC EYES; HYSTERESIS; THICKNESS;
D O I
10.1111/j.1755-3768.2010.02093.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the relationship between biomechanical properties of the cornea and intraocular pressure (IOP) and the role of biomechanical properties in eyes of patients with unilateral primary open-angle glaucoma (POAG). Methods: The biomechanical properties of corneal hysteresis (CH) and the corneal resistance factor (CRF) were measured with the ocular response analyser (ORA). In an experimental setting, three human donor eyes with Schiotz-tonometry-controlled IOP were investigated. In addition, a series of patients with unilateral POAG were evaluated. Main outcome measures were CH, CRF, corneal-compensated IOP (IOPcc), standard automated perimetry parameters mean defect (MD) and pattern standard deviation, central corneal thickness, Goldmann applanation tonometry (GAT), and cup-to-disc ratio. Results: A highly significant linear correlation between CH and the corneal-compensated IOP (IOPcc, r = -0.926; p < 0.001) was found. The correlation between IOP(CC) and CRF was not significant (r = 0.335; p = 0.08). In total, 36 eyes of 18 patients with unilateral POAG were examined. Regarding uncorrected CH (mean 7.73 +/- 1.46 mmHg glaucomatous eye and 9.28 +/- 1.42 mmHg fellow eye), there was a highly significant difference between both eyes. This difference disappears, when CH was corrected for IOP (9.44 +/- 3.78 mmHg and 9.97 +/- 3.22 mmHg, respectively). Conclusions: Corneal hysteresis but not corneal resistance factor is dependent on IOP. In patients with unilateral POAG, IOP is higher in the affected eye. When CH is corrected for IOP, corneal biomechanical properties do not differ in both eyes of patients with unilateral POAG.
引用
收藏
页码:E189 / E192
页数:4
相关论文
共 19 条
[1]   Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes [J].
Abitbol, Olivia ;
Bouden, Jihene ;
Doan, Serge ;
Hoang-Xuan, Thanh ;
Gatinel, Damien .
ACTA OPHTHALMOLOGICA, 2010, 88 (01) :116-119
[2]   The heritability of corneal hysteresis and ocular pulse amplitude - A twin study [J].
Carbonaro, Francis ;
Andrew, Toby ;
Mackey, David A. ;
Spector, Tim D. ;
Hammond, Chris J. .
OPHTHALMOLOGY, 2008, 115 (09) :1545-1549
[3]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[4]   Corneal Biomechanical Metrics and Anterior Segment Parameters in Mild Keratoconus [J].
Fontes, Bruno M. ;
Ambrosio, Renato, Jr. ;
Jardim, Daniela ;
Velarde, Guillermo C. ;
Nose, Walton .
OPHTHALMOLOGY, 2010, 117 (04) :673-679
[5]   Methods of measuring intraocular pressure independently of central corneal thickness [J].
Hager, A. ;
Wiegand, W. .
OPHTHALMOLOGE, 2008, 105 (09) :840-844
[6]   Role of corneal elasticity in damping of intraocular pressure [J].
Johnson, C. Starck ;
Mian, Shahzad I. ;
Moroi, Sayoko ;
Epstein, David ;
Izatt, Joseph ;
Afshari, Natalie A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (06) :2540-2544
[7]   Factors affecting corneal hysteresis in normal eyes [J].
Kamiya, Kazutaka ;
Hagishima, Mana ;
Fujimura, Fusako ;
Shimizu, Kimiya .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (10) :1491-1494
[8]   Corneal hysteresis and corneal resistance factor in keratoectasia: Findings using the Reichert Ocular Response Analyzer [J].
Kirwan, Caitriona ;
O'Malley, Donal ;
O'Keefe, Michael .
OPHTHALMOLOGICA, 2008, 222 (05) :334-337
[9]   Corneal hysteresis and intraocular pressure measurement in children using the Reichert Ocular Response Analyzer [J].
Kirwan, Caitriona ;
O'Keefe, Michael ;
Lanigan, Bernadette .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (06) :990-992
[10]   Determining in vivo biomechanical properties of the cornea with an ocular response analyzer [J].
Luce, DA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :156-162