Measuring defibrillator surface potentials: The validation of a predictive defibrillation computer model

被引:5
作者
Tate, Jess [1 ,2 ]
Stinstra, Jeroen [1 ,2 ]
Pilcher, Thomas [3 ]
Poursaid, Ahrash [1 ,2 ]
Jolley, Matthew A. [4 ]
Saarel, Elizabeth [3 ]
Triedman, John [5 ]
MacLeo, Rob S. [1 ,2 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT USA
[3] Univ Utah, Div Pediat Cardiol, Salt Lake City, UT USA
[4] Childrens Hosp Philadelphia, Dept Anesthesiol & Crit Care Med, Philadelphia, PA 19104 USA
[5] Childrens Hosp Boston, Dept Cardiol, Boston, MA USA
基金
美国国家卫生研究院;
关键词
Defibrillation; Patient-specific modeling; Limited lead selection; Body surface mapping; Defibrillation threshold; Defibrillation modeling; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; HIGH-RISK; MYOCARDIAL-INFARCTION; LEAD SELECTION; CHILDREN; INSIGHTS; DISEASE; HEART; MAPS;
D O I
10.1016/j.compbiomed.2018.08.025
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Implantable cardioverter defibrillators (ICDs) are commonly used to reduce the risk in patients with life threatening arrhythmias, however, clinicians have little systematic guidance to place the device, especially in cases of unusual anatomy. We have previously developed a computational model that evaluates the efficacy of a delivered shock as a clinical and research aid to guide ICD placement on a patient specific basis. We report here on progress to validate this model with measured ICD surface potential maps from patients undergoing ICD implantation and testing for defibrillation threshold (DFT). We obtained body surface potential maps of the defibrillation pulses by adapting a limited lead selection and potential estimation algorithm to deal with the limited space for recording electrodes. Comparison of the simulated and measured potential maps of the defibrillation shock yielded similar patterns, a typical correlation greater than 0.9, and a relative error less than 15%. Comparison of defibrillation thresholds also showed accurate prediction of the simulations. The high agreement of the potential maps and DFTs suggests that the predictive simulation generates realistic potential values and can accurately predict DFTs in patients. These validation results pave the way for use of this model in optimization studies prior to device implantation.
引用
收藏
页码:402 / 410
页数:9
相关论文
共 48 条
[21]   Use of a wearable defibrillator in terminating tachyarrhythmias in patients at high risk for sudden death: Results of WEARIT/BIROAD [J].
Feldman, AM ;
Klein, H ;
Tchou, P ;
Murali, S ;
Hall, WJ ;
Mancini, D ;
Boehmer, J ;
Harvey, M ;
Hellman, MS ;
Szymkiewicz, SJ ;
Moss, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (01) :4-9
[22]   CURRENT CONCEPTS FOR SELECTING THE LOCATION, SIZE AND SHAPE OF DEFIBRILLATION ELECTRODES [J].
IDEKER, RE ;
WOLF, PD ;
ALFERNESS, C ;
KRASSOWSKA, W ;
SMITH, WM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :227-&
[23]   Novel electrode design for potentially painless internal defibrillation also allows for successful external defibrillation [J].
Jayanti, Venku ;
Zviman, Menekhem M. ;
Nazarian, Saman ;
Halperin, Henry R. ;
Berger, Ronald D. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (10) :1095-1100
[24]   A computer modeling tool for comparing novel ICD electrode orientations in children and adults [J].
Jolley, Matthew ;
Stinstra, Jeroen ;
Pieper, Steve ;
MacLeod, Rob ;
Brooks, Dana H. ;
Cecchin, Frank ;
Triedman, John K. .
HEART RHYTHM, 2008, 5 (04) :565-572
[25]  
Jolley Matthew, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P2564
[26]   Finite element modeling of subcutaneous implantable defibrillator electrodes in an adult torso [J].
Jolley, Matthew ;
Stinstra, Jeroen ;
Tate, Jess ;
Pieper, Steve ;
MacLeod, Rob ;
Chu, Larry ;
Wang, Paul ;
Triedman, John K. .
HEART RHYTHM, 2010, 7 (05) :692-698
[27]   PREDICTING CARDIOTHORACIC VOLTAGES DURING HIGH-ENERGY SHOCKS - METHODOLOGY AND COMPARISON OF EXPERIMENTAL TO FINITE-ELEMENT MODEL DATA [J].
JORGENSON, DB ;
SCHIMPF, PH ;
SHEN, I ;
JOHNSON, G ;
BARDY, GH ;
HAYNOR, DR ;
KIM, YM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (06) :559-571
[28]   IDENTIFICATION OF BEST ELECTROCARDIOGRAPHIC LEADS FOR DIAGNOSING MYOCARDIAL-INFARCTION BY STATISTICAL-ANALYSIS OF BODY-SURFACE POTENTIAL MAPS [J].
KORNREICH, F ;
RAUTAHARJU, PM ;
WARREN, J ;
MONTAGUE, TJ ;
HORACEK, BM .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (13) :852-856
[29]   Nontransvenous implantable cardioverter defibrillator systems: Not just for small pediatric patients [J].
Kugler, JD ;
Erickson, CC .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (01) :47-48
[30]   Acute defibrillation performance of a novel, non-transvenous shock pathway in adult ICD indicated patients [J].
Lieberman, Randy ;
Havel, William J. ;
Rashba, Eric ;
DeGroot, Paul J. ;
Stromberg, Kurt ;
Shorofsky, Stephen R. .
HEART RHYTHM, 2008, 5 (01) :28-34