Collisional frequency shifts in 133Cs fountain clocks

被引:0
|
作者
Leo, PJ [1 ]
Julienne, PS [1 ]
Mies, FH [1 ]
Williams, CJ [1 ]
机构
[1] Natl Inst Stand & Technol, Atom Phys Div, Gaithersburg, MD 20899 USA
关键词
D O I
10.1103/PhysRevLett.86.3743
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Wie present a theoretical analysis of the density dependent frequency shift in Cs fountain clocks using the highly constrained binary collision model described by Leo et al. [Phys. Rev Lett. 85, 2721 (2000)]. We predict a reversal in the clock shift at temperatures near 0.08 muK. OUT results show that s waves; dominate the collision process. However, as a consequence of the large scattering lengths in Ca the clock shift is strongly temperature dependent and does not reach a constant Wigner-law value until temperatures are less than 0.1 nK.
引用
收藏
页码:3743 / 3746
页数:4
相关论文
共 50 条
  • [1] Progress towards a 133Cs fountain as frequency standard in Brazil
    Magalhaes, DV
    Santos, MS
    Bebeachibuli, A
    Müller, ST
    Bagnato, VS
    LASER PHYSICS, 2004, 14 (02) : 150 - 153
  • [2] Characterization of the main frequency shifts for the Brazilian 133Cs atomic beam frequency standard
    Bebeachibuli, A
    Santos, MS
    Magalhaes, DV
    Müller, ST
    Bagnato, VS
    BRAZILIAN JOURNAL OF PHYSICS, 2005, 35 (4A) : 1010 - 1015
  • [3] Cancellation of the collisional frequency shift in caesium fountain clocks
    Szymaniec, K.
    Chalupczak, W.
    Tiesinga, E.
    Williams, C. J.
    Weyers, S.
    Wynands, R.
    PHYSICAL REVIEW LETTERS, 2007, 98 (15)
  • [4] Manipulation of the collisional frequency shift in caesium fountain clocks
    Szymaniec, K.
    Chalupczak, W.
    Weyers, S.
    Wynands, R.
    Tiesinga, E.
    Williams, C. J.
    TIME AND FREQUENCY METROLOGY, 2007, 6673
  • [5] ISOMER SHIFTS OF 81 KEV GAMMA-LINE OF 133CS
    HENNING, W
    QUITMANN, D
    STEICHELE, E
    HUFNER, S
    KIENLE, P
    ZEITSCHRIFT FUR PHYSIK, 1968, 209 (01): : 33 - +
  • [6] Suppression of Microwave Leakage Shifts in Fountain Clocks by Frequency Detuning
    Kazda, Michael
    Gerginov, Vladislav
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (10) : 2389 - 2393
  • [7] High precision frequency measurements in thermal 133Cs cell
    Gerginov, V
    Tanner, C
    11TH INTERNATIONAL SCHOOL ON QUANTUM ELECTRONICS: LASER PHYSICS AND APPLICATIONS, 2001, 4397 : 166 - 170
  • [8] Nonlinear Pressure Shifts of 87Rb and 133Cs in Ar and Kr
    Gong, F.
    Jau, Y. -Y.
    Happer, W.
    2008 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, VOLS 1 AND 2, 2008, : 115 - 117
  • [9] Advances in the NIM Cs fountain clocks
    Fang, Fang
    Chen, Weiliang
    Liu, Kun
    Dai, Shaoyang
    Liu, Nianfeng
    Han, Lei
    Zheng, Fasong
    Li, Tianchu
    PROCEEDINGS OF THE 2019 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EUROPEAN FREQUENCY AND TIME FORUM (EFTF-IFCS 2019), 2019,
  • [10] 87Rb and 133Cs laser cooled clocks:: Testing the stability of fundamental constants
    Dos Santos, FP
    Marion, H
    Abgrall, M
    Zhang, S
    Sortais, Y
    Bize, S
    Maksimovic, I
    Calonico, D
    Grünert, J
    Mandache, C
    Vian, C
    Rosenbuch, P
    Lemonde, P
    Santarelli, G
    Laurent, P
    Clairon, A
    Salomon, C
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION JOINTLY WITH 17TH EUROPEAN FREQUENCY AND TIME FORUM, 2003, : 55 - 67