Microfluidic chip-based cell electrophoresis with multipoint laser-induced fluorescence detection system

被引:12
作者
Yu, Linfen [1 ]
Shen, Zheng [1 ]
Mo, Jiankun [2 ]
Dong, Xiuling [3 ]
Qin, Jianhua [1 ]
Lin, Bingcheng [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dept Biotechnol, Dalian 116023, Peoples R China
[2] 2nd Peoples Hosp Guangdong Prov, Guangdong, Peoples R China
[3] Dalian Third Municipal Hosp, Dalian, Peoples R China
关键词
cell electrophoresis; K562; cells; microfluidic chip; multipoint detection;
D O I
10.1002/elps.200700313
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the electrophoretic mobility (EPM) measurement of individual cells was investigated by a simple on-chip electrophoresis system with LIF multipoint detection. The system enabled the characterization of cell electrophoresis behavior as well as the fluorescence signal from individual cells simultaneously. The measurement yielded the electropherograms of a large number of cells labeled with dye, in which the migration time and migration distance could be obtained easily. The EPM has been demonstrated to be different between the K562 cells and K562 cells treated with anticancer drug arsenic trioxide (AS(2)O(3)). The K562 cells were found to exhibit a lower EPM compared to the cells after drug addition with different concentration. In this preliminary study, over 300 cells could be analyzed within 2 h, demonstrated a much higher analysis throughput compared with traditional methods. The established system is simple and fast, which is expected to be a promising method for evaluating cell surface properties and to be useful in clinical and pharmaceutical applications.
引用
收藏
页码:4741 / 4747
页数:7
相关论文
共 20 条
[11]   Measurement of electroosmotic flow in plastic imprinted microfluid devices and the effect of protein adsorption on flow rate [J].
Locascio, LE ;
Perso, CE ;
Lee, CS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :275-284
[12]   CHANGE IN ELECTROPHORETIC MOBILITY OF HL-60RG CELLS BY APOPTOSIS [J].
MAKINO, K ;
IKEKITA, M ;
KONDO, T ;
TANUMA, S ;
OHSHIMA, H .
COLLOID AND POLYMER SCIENCE, 1994, 272 (04) :487-492
[13]  
Mehrishi JN, 2002, ELECTROPHORESIS, V23, P1984, DOI 10.1002/1522-2683(200207)23:13<1984::AID-ELPS1984>3.0.CO
[14]  
2-U
[15]  
RONOT X, 1986, BIOL CELL, V57, P1
[16]  
SU YK, 2004, CHIN J CLIN PHARM TH, V9, P308
[17]   Determination of reactive oxygen species in single human erythrocytes using microfluidic chip electrophoresis [J].
Sun, Y ;
Yin, XF ;
Ling, YY ;
Fang, ZL .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (07) :1472-1476
[18]   Chemical cytometry on a picoliter-scale integrated microfluidic chip [J].
Wu, HK ;
Wheeler, A ;
Zare, RN .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (35) :12809-12813
[19]  
Yu LF, 2004, CHINESE J ANAL CHEM, V32, P557
[20]   Determination of SARS-coronavirus by a microfluidic chip system [J].
Zhou, ZM ;
Liu, DY ;
Zhong, RT ;
Dai, ZP ;
Wu, DP ;
Wang, H ;
Du, YG ;
Xia, ZN ;
Zhang, LP ;
Mei, XD ;
Lin, BC .
ELECTROPHORESIS, 2004, 25 (17) :3032-3039