The Activ8 activity monitor: Validation of posture and movement classification

被引:13
作者
Horemans, Herwin [1 ]
Kooijmans, Hedwig [1 ]
van den Berg-emons, Rita [1 ]
Bussmann, Hans [1 ]
机构
[1] Erasmus MC, Wytemaweg 80, NL-3000 CA Rotterdam, Netherlands
来源
JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING | 2020年 / 7卷
关键词
Accelerometry; physical activity; physical activity assessment; piezoelectric devices; rehabilitation devices; PHYSICAL-ACTIVITY; ENERGY-EXPENDITURE; VALIDITY; ADULTS; BEHAVIOR; DISEASE; WORN;
D O I
10.1177/2055668319890535
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: To set up and guide interventions with the aim to increase physical activity and lower sedentary behavior valid monitoring of physical behavior is essential. The aim of this study was to evaluate the validity of the single-unit Activ8 activity monitor to classify several body postures and movements. Methods: Twelve healthy adults performed a series of activities, representative for everyday life, according to a standard protocol. Activ8 was both worn in the trouser pocket (prescribed location) and fixated to the front of the thigh. Activities were video recorded and analyzed thereafter. Postures and movements that were analyzed were lying/sitting, standing, walking, cycling, and running. Results: The agreement between Activ8 output and video analysis was 89.7% (inter-subject range: 66.0 to 96.6%) for the pocket location and 91.9% (range 85.5 to 95.1%) for the thigh location. Sensitivity and positive predictive value scores for both locations were all above 80%, except for standing (69% or higher). Differences in classified duration of separate postures and movements were within 20% for walking, sitting and running. Conclusion: The Activ8 is a valid instrument to quantify a defined set of body postures and movements. Because of the smaller time difference, the thigh location is preferred for research purposes.
引用
收藏
页码:1 / 8
页数:7
相关论文
共 27 条
  • [1] The Current State of Physical Activity Assessment Tools
    Ainsworth, Barbara
    Cahalin, Lawrence
    Buman, Matthew
    Ross, Robert
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 2015, 57 (04) : 387 - 395
  • [2] Accuracy of Three Activity Monitors in Patients with Chronic Obstructive Pulmonary Disease: A Comparison with Video Recordings
    Andersson, Mikael
    Janson, Christer
    Emtner, Margareta
    [J]. COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2014, 11 (05) : 560 - 567
  • [3] [Anonymous], 2013, ACTIV8
  • [4] Calibration and Validation of Wearable Monitors
    Bassett, David R., Jr.
    Rowlands, Alex
    Trost, Stewart G.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : S32 - S38
  • [5] Sedentary Time and Its Association With Risk for Disease Incidence, Mortality, and Hospitalization in Adults A Systematic Review and Meta-analysis
    Biswas, Aviroop
    Oh, Paul I.
    Faulkner, Guy E.
    Bajaj, Ravi R.
    Silver, Michael A.
    Mitchell, Marc S.
    Alter, David A.
    [J]. ANNALS OF INTERNAL MEDICINE, 2015, 162 (02) : 123 - +
  • [6] Measuring daily behavior using ambulatory accelerometry: The activity monitor
    Bussmann, JBJ
    Martens, WLJ
    Tulen, JHM
    Schasfoort, FC
    van den Berg-Emons, HJG
    Stam, HJ
    [J]. BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 2001, 33 (03): : 349 - 356
  • [7] Ambulatory Activity Monitoring Progress in Measurement of Activity, Posture, and Specific Motion Patterns in Daily Life
    Bussmann, Johannes B. J.
    Ebner-Priemer, Ulrich W.
    Fahrenberg, Jochen
    [J]. EUROPEAN PSYCHOLOGIST, 2009, 14 (02) : 142 - 152
  • [8] A Comparison of Energy Expenditure Estimation of Several Physical Activity Monitors
    Dannecker, Kathryn L.
    Sazonova, Nadezhda A.
    Melanson, Edward L.
    Sazonov, Edward S.
    Browning, Raymond C.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (11) : 2105 - 2112
  • [9] Dasenbrock L, 2016, Z GERONTOL GERIATR, V49, P581, DOI 10.1007/s00391-016-1129-7
  • [10] Validity and reliability of measuring activities, movement intensity and energy expenditure with the DynaPort MoveMonitor
    de Groot, Sonja
    Nieuwenhuizen, Mieke G.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2013, 35 (10) : 1499 - 1505