Nodal metastasis in non-small cell lung cancer: Accuracy of 3.0-T MR imaging

被引:21
作者
Kim, Ha Young [1 ,2 ]
Yi, Chin A. [1 ,2 ]
Lee, Kyung Soo [1 ,2 ]
Chung, Myung Jin [1 ,2 ]
Kim, Yoon Kyung [1 ,2 ]
Choi, Bong Keun [4 ]
Kim, Hojoong [3 ]
Kwon, O. Jung [3 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul 135710, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Div Pulm & Crit Care Med,Dept Med, Seoul 135710, South Korea
[4] Kyung Hee Univ, Dept Biostat, Coll Med, Seoul, South Korea
关键词
D O I
10.1148/radiol.2461061907
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively evaluate the diagnostic accuracy of 3.0-T magnetic resonance (MR) imaging in the detection of non small cell lung cancer nodal metastasis, with histopathologic analysis as the reference standard. Materials and Methods: Institutional review board approval and informed consent were obtained. From July 2005 to May 2006, 113 patients (91 men 22 women; age range, 34-82 years; mean age, 61 years) with non-small cell lung cancer underwent thoracic 3.0-T MR imaging followed by surgery or mediastinoscopy. The lymph node-to-tumor ratios (LTRs) of signal intensity and nodal morphologic characteristics (such as eccentric cortical thickening or obliteration of the fatty hilum) were -assessed- on T2-weighted triple-inversion black-blood fast spin-echo images. Nodal short-axis diameter was assessed on T1-weighted three dimensional fast field-echo images. Receiver operating characteristic and multivariate logistic regression analyses were used for staptistical evaluation. Results: The cutoff value (LTR > 0.84) proved to be most appropriate (area under the :receiver operating characteristic curve = 0.735, P < .001) in the detection of a nodal metastasis. Of the various parameters examined, morphologic characteristics appeared to be the most significant (P < .001) parameters foil depicting a malignant node (multivariate logistic regression analyses; odds ratio, 7.5). Nodal morphology was analyzed, and diagnostic sensitivity, specificity, and accuracy were 53% (39 of 74 nodal stations), 91% (453 of 496 nodal stations), and 86% (492 of 570 nodal stations), respectively. Conclusion: Morphologic details of lymph nodes on T2 weighted triple inversion black-blood fast spin-echo MR images are significant for detection of mediastinal or hilar nodal metastasis tit 3.0-T MR imaging, (C) RSNA, 2007.
引用
收藏
页码:596 / 604
页数:9
相关论文
共 41 条
[1]  
Boiselle P M, 2000, Magn Reson Imaging Clin N Am, V8, P33
[2]   Imaging of mediastinal lymph nodes: CT, MR, and FDG PET [J].
Boiselle, PM ;
Patz, EF ;
Vining, DJ ;
Weissleder, R ;
Shepard, JO ;
McLoud, TC .
RADIOGRAPHICS, 1998, 18 (05) :1061-1069
[3]   MR imaging abbreviations, definitions, and descriptions: A review [J].
Brown, MA ;
Semelka, RC .
RADIOLOGY, 1999, 213 (03) :647-662
[4]  
Campeau N G, 2001, Top Magn Reson Imaging, V12, P183, DOI 10.1097/00002142-200106000-00005
[5]  
Chakraborti K L, 1997, Indian J Chest Dis Allied Sci, V39, P19
[6]   Metastases from non-small cell lung cancer: Mediastinal staging in the 1990s - Meta-analytic comparison of PET and CT [J].
Dwamena, BA ;
Sonnad, SS ;
Angobaldo, JO ;
Wahl, RL .
RADIOLOGY, 1999, 213 (02) :530-536
[7]   CT, MR, and PET imaging in staging of non-small-cell lung cancer [J].
Erasmus, JJ ;
Truong, MT ;
Munden, RF .
SEMINARS IN ROENTGENOLOGY, 2005, 40 (02) :126-142
[8]   Ultrasound of superficial lymph nodes [J].
Esen, Gul .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (03) :345-359
[9]   Whole body turbo STIR MRI in unknown primary tumor detection [J].
Eustace, S ;
Tello, R ;
DeCarvalho, V ;
Carey, J ;
Melhem, E ;
Yucel, EK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :751-753
[10]   MEDIASTINAL LYMPH-NODES - RELAXATION-TIME PATHOLOGIC CORRELATION AND IMPLICATIONS IN STAGING OF LUNG-CANCER WITH MR IMAGING [J].
GLAZER, GM ;
ORRINGER, MB ;
CHENEVERT, TL ;
BORRELLO, JA ;
PENNER, MW ;
QUINT, LE ;
LI, KC ;
AISEN, AM .
RADIOLOGY, 1988, 168 (02) :429-431