Simultaneous Determination of Benzo(a)pyrene, Benzo(a)anthracene, Benzo(b)fluoranthene, and Chrysene in Tocotrienol Concentrates Using Dual Solid-phase Extraction and Gas Chromatography-Mass Spectrometry

被引:1
|
作者
Hor, Jia Yi [1 ]
Hassan, Norfarizah Hanim [1 ]
Zulkarnain, Musfirah [2 ]
Abd Latip, Razam [3 ]
Nidzam, Mohammad Saiful [3 ]
Wong, Yong Foo [1 ]
机构
[1] Univ Sains Malaysia, Ctr Res Multidimens Separat Sci, Sch Chem Sci, George Town 11800, Malaysia
[2] Univ Sains Malaysia, Sch Ind Technol, Food Technol Div, George Town 11800, Malaysia
[3] Sime Darby Plantat Res Sdn Bhd, Pulau Carey 42960, Selangor, Malaysia
关键词
Polyaromatic hydrocarbon; GC-MS; tocotrienol rich fraction; LLE; dSPE; tocotrienol homologues; POLYCYCLIC AROMATIC-HYDROCARBONS; EDIBLE VEGETABLE-OILS; PAHS CONTENT; SAMPLES;
D O I
10.2174/1573411018666220603093732
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Polyaromatic hydrocarbons (PAHs) are a class of toxic compounds commonly found in edible vegetable oils as a result of contamination through food processing. Among the wide variety of PAHs existing in edible oils, benzo(a)pyrene (BAP), benzo(a)anthracene (BAA), benzo(b)fluoranthene (BBF), and chrysene (CHR) are commonly monitored due to their toxicity, carcinogenic and teratogenic properties. Materials and Methods: In this context, we described a combination of liquid-liquid extraction and dual cartridge solid-phase extraction (dSPE) system for the extraction of BAP, BAA, BBF, and CHR in palm oil derived tocotrienol rich fraction (T3RF), followed by their analysis using GC-MS operating in selected ion monitoring mode (SIM). Results: The separation was effected using a DB-5HT column (30 m x 0.25 mm x 0.25 mu m) that can operate at a high temperature limit of 400 degrees C, which enables the separation of the PAHs in < 28 min. The calibration curves were correlated within the range of 1.5-25 mu g/ L, with detection limits (S/N: 3.3) of 0.48-1.35 mu g/L, and relative standard deviations of <= 0.07% and <= 6.85% were achieved for intra-day retention times and peak areas. Conclusion: The proposed sample preparation and GC-SIM workflow greatly reduces interference caused by tocotrienol homologues and enables the quantitative determination of BAP, BAA, BBF, and CHR in T3RF and palm fatty acid distillates.
引用
收藏
页码:930 / 937
页数:8
相关论文
共 50 条
  • [41] Magnesium oxide microspheres as a novel solid-phase extraction sorbent for the determination of benzo[a]pyrene in environmental water samples
    Jin, Jing
    Zhang, Zhiping
    Wang, Jincheng
    Qi, Peipei
    Chen, Jiping
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (12) : 1836 - 1841
  • [42] Simultaneous determination of twelve natural estrogens in dairy milk using liquid–liquid extraction and solid-phase extraction coupled with gas chromatography-mass spectrometry
    De-ming Kong
    Zhao Tang
    Ze-hua Liu
    Zhi Dang
    Peng-ran Guo
    Yu-mei Song
    Yu Liu
    Environmental Science and Pollution Research, 2023, 30 : 112908 - 112921
  • [43] Determination of Phthalates in Marine Sediments Using Ultrasonic Extraction Followed by Dispersive Solid-Phase Extraction and Gas Chromatography-Mass Spectrometry
    Hu, Hongmei
    Li, Tiejun
    Bao, Jingjiao
    Zhang, Xiaoning
    Sun, Xiumei
    Xu, Kaida
    Liu, Qin
    Guo, Yuanming
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (03) : 207 - 216
  • [44] Simultaneous determination of endocrine disrupting phenolic compounds and steroids in water by solid-phase extraction-gas chromatography-mass spectrometry
    Liu, R
    Zhou, JL
    Wilding, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) : 179 - 189
  • [45] Simultaneous determination of fifteen low-dosed benzodiazepines in human urine by solid-phase extraction and gas chromatography-mass spectrometry
    Borrey, D
    Meyer, E
    Lambert, W
    Van Peteghem, C
    De Leenheer, AP
    JOURNAL OF CHROMATOGRAPHY B, 2001, 765 (02): : 187 - 197
  • [46] Determination of estrogenic nonylphenol and bisphenol A in river water by solid-phase extraction and gas chromatography-mass spectrometry
    Ding, WH
    Wu, CY
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2000, 47 (05) : 1155 - 1160
  • [47] Determination of tebufenpyrad and oxadiazon by solid-phase microextraction and gas chromatography-mass spectrometry
    Navalón, A
    Prieto, A
    Araujo, L
    Vílchez, JL
    CHROMATOGRAPHIA, 2001, 54 (5-6) : 377 - 382
  • [48] Determination of tebufenpyrad and oxadiazon by solid-phase microextraction and gas chromatography-mass spectrometry
    A. Navalón
    A. Prieto
    L. Araujo
    J. L. Vílchez
    Chromatographia, 2001, 54 : 377 - 382
  • [49] Continuous solid-phase extraction and gas chromatography-mass spectrometry determination of pharmaceuticals and hormones in water samples
    Azzouz, A.
    Souhail, B.
    Ballesteros, E.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (17) : 2956 - 2963
  • [50] Pipette tip solid-phase extraction and gas chromatography-mass spectrometry for the determination of mequitazine in human plasma
    Kumazawa, Takeshi
    Hasegawa, Chika
    Lee, Xiao-Pen
    Marumo, Akemi
    Shimmen, Natsuko
    Ishii, Akira
    Seno, Hiroshi
    Sato, Keizo