Automatic determination of left ventricular ejection fraction from gated blood-pool tomography

被引:0
|
作者
Vanhove, C [1 ]
Franken, PR [1 ]
Defrise, M [1 ]
Momen, A [1 ]
Everaert, H [1 ]
Bossuyt, A [1 ]
机构
[1] Free Univ Brussels, AZ VUB, Univ Hosp, Div Nucl Med, B-1090 Brussels, Belgium
关键词
blood-pool SPECT; automatic algorithm; left ventricular ejection fraction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to develop and validate a new algorithm to automatically compute left ventricular ejection fraction (LVEF) from gated blood-pool tomography (GBPT). The results were compared with those of conventional planar radionuclide angiocardiography (PRNA). Methods: Fifty-three consecutive patients received an injection of 740 MBq Tc-99m-labeled human serum albumin. PRNA and GBPT were performed consecutively in a random sequence. PRNA served as the reference, and GBPT images were processed using a new edge detection algorithm. The algorithm is fast (<45 s), fully automatic, and works in three-dimensional space. The method includes identification of the Valve plane and the septum, The left ventricular cavity at end-diastole is delineated by segmentation using an iterative threshold technique. An optimal threshold is reached when the corresponding isocontour best fits the first derivative of the end-diastolic count distribution in three dimensions. This optimal threshold is then applied to delineate the left Ventricular cavity on the other time bins. The data are corrected for the partial-volume effect. Left ventricular Volumes are determined using a geometry-based method and are used to calculate the ejection fraction. Results: The success rate of the new algorithm was 94%, LVEFs calculated from GBPT agreed well with those calculated from PRNA (r = 0.78; GBPT = 0.94 PRNA + 6.33). The systematic error was 2.8%, and the random error was 8.8%. Excellent inter- and intraobserver reproducibility was found, with average differences of 1.1% +/- 4.6% and 1.1% +/- 5.0%, respectively, between the two measurements. Conclusion: This new algorithm provides a fast, automated, and objective method to calculate LVEF from GBPT.
引用
收藏
页码:401 / 407
页数:7
相关论文
共 50 条
  • [21] Differences in left ventricular ejection fraction and volumes measured at rest and poststress by gated sestamibi SPECT
    Gautam Ramakrishna
    Todd D. Miller
    Raymond J. Gibbons
    David O. Hodge
    Michael K. O’Connor
    Journal of Nuclear Cardiology, 2006, 13 : 668 - 674
  • [22] Effect of prone versus supine positioning on left ventricular ejection fraction (LVEF) and heart rate using ECG gated Tl-201 myocardial perfusion scans and gated cardiac blood pool scans
    Yap, Kenneth
    Campbell, Patrina
    Cherk, Martin
    McGrath, Catherine
    Kalff, Victor
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (05) : 525 - 531
  • [23] Left Ventricular Ejection Fraction What Is "Normal"?
    Fonarow, Gregg C.
    Hsu, Jeffrey J.
    JACC-HEART FAILURE, 2016, 4 (06) : 511 - 513
  • [24] Left Ventricular Ejection Fraction and Volumes: It Depends on the Imaging Method
    Wood, Peter W.
    Choy, Jonathan B.
    Nanda, Navin C.
    Becher, Harald
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (01): : 87 - 100
  • [25] The value of a completely automatic ECG gated blood pool SPECT processing method for the estimation of global systolic left ventricular function
    Daou, D
    Coaguila, C
    Benada, A
    Razzouk, M
    Haidar, M
    Colin, P
    Lebtahi, R
    Slama, M
    Le Guludec, D
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (03) : 271 - 276
  • [26] Dynamic trajectories of left ventricular ejection fraction in heart failure with improved ejection fraction
    Jiang, Yang
    Chen, Xuefu
    Zhang, Xinxin
    Dong, Shuang
    Liu, Ying
    BMC CARDIOVASCULAR DISORDERS, 2024, 24 (01):
  • [27] Heart Failure With Midrange Ejection Fraction: Prior Left Ventricular Ejection Fraction and Prognosis
    Zhang, Xinxin
    Sun, Yuxi
    Zhang, Yanli
    Chen, Feifei
    Zhang, Shuyuan
    He, Hongyan
    Song, Shuang
    Tse, Gary
    Liu, Ying
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [28] Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT
    Vallejo, E
    Chaya, H
    Plancarte, G
    Victoria, D
    Bialostozky, D
    JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (04) : 377 - 384
  • [29] Variability of serial same-day left ventricular ejection fraction using quantitative gated spect
    Enrique Vallejo
    Hugo Chaya
    Gerardo Plancarte
    Diana Victoria
    David Bialostozky
    Journal of Nuclear Cardiology, 2002, 9 : 377 - 384
  • [30] Left ventricular ejection fraction: time to revise the metric?
    Ray, Avik
    Zlotoff, Dan
    Kawachi, Ichiro
    POSTGRADUATE MEDICAL JOURNAL, 2024, 100 (1189) : 875 - 876