Strengthening of steel-concrete composite beams with composite slab

被引:12
作者
Subhani, Mahbube [1 ]
Kabir, Muhammad Ikramul [1 ]
Al-Ameri, Riyadh [1 ]
机构
[1] Deakin Univ, Sch Engn, 75 Pigdons Rd, Waurn Ponds, Vic 3216, Australia
关键词
strengthening; steel-concrete composite; FRP; welded plate; longitudinal shear; profiled steel sheeting; steel deck; FLEXURAL BEHAVIOR; GIRDERS; REPAIR; CONNECTORS; STRESS;
D O I
10.12989/scs.2020.34.1.091
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite beam with profiled steel sheet has gained its popularity in the last two decades. Due to the ageing of these structures, retrofitting in terms of flexural strength is necessary to ensure that the aged structures can carry the increased traffic load throughout their design life. The steel ribs, which presented in the profiled steel deck, limit the use of shear connectors. This leads to a poor degree of composite action between the concrete slab and steel beam compared to the solid slab situation. As a result, the shear connectors that connects the slab and beam will be subjected to higher shear stress which may also require strengthening to increase the load carrying capacity of an existing composite structure. While most of the available studies focus on the strengthening of longitudinal shear and flexural strength separately, the present work investigates the effect of both flexural and longitudinal shear strengthening of steel-concrete composite beam with composite slab in terms of failure modes, ultimate load carrying capacity, ductility, end-slip, strain profile and interface differential strain. The flexural strengthening was conducted using carbon fibre reinforced polymer (CFRP) or steel plate on the soffit of the steel I-beam, while longitudinal shear capacity was enhanced using post-installed high strength bolts. Moreover, a combination of both the longitudinal shear and flexural strengthening techniques was also implemented (hybrid strengthening). It is concluded that hybrid strengthening improved the ultimate load carrying capacity and reduce slip and interface differential strain that lead to improved composite action. However, hybrid strengthening resulted in brittle failure mode that decreased ductility of the beam.
引用
收藏
页码:91 / 105
页数:15
相关论文
共 39 条
[21]   Experimental investigation of longitudinal shear behavior for composite floor slab [J].
Kataoka, Marcela N. ;
Friedrich, Juliana T. ;
El Debs, Ana Lucia H. C. .
STEEL AND COMPOSITE STRUCTURES, 2017, 23 (03) :351-362
[22]   Behavior of post-installed shear connectors under static and fatigue loading [J].
Kwon, Gunup ;
Engelhardt, Michael D. ;
Klingner, Richard E. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (04) :532-541
[23]  
LORENZ RF, 1984, ENG J AISC, V21, P185
[24]  
Miller T.C., 2001, J BRIDGE ENG, V6, P514, DOI DOI 10.1061/(ASCE)1084-0702(2001)6:6(514)
[25]   Strengthening of steel-concrete composite girders using carbon fibre reinforced polymer (CFRP) plates [J].
Mosavi, S. M. ;
Nik, A. Sadeghi .
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2015, 40 (01) :249-261
[26]   Effect of Longitudinal Carbon Fiber-Reinforced Polymer Plates on Shear Strength of Reinforced Concrete Beams [J].
Nawaz, Waleed ;
Hawileh, Rami A. ;
Saqan, Elias I. ;
Abdalla, Jamal A. .
ACI STRUCTURAL JOURNAL, 2016, 113 (03) :577-586
[27]   Stiffness and capacity of steel-concrete composite beams with profiled sheeting [J].
Nie, J ;
Cai, CS ;
Wang, T .
ENGINEERING STRUCTURES, 2005, 27 (07) :1074-1085
[28]   Experimental study of partially shear-connected composite beams with profiled sheeting [J].
Nie, Jianguo ;
Fan, Jiansheng ;
Caib, C. S. .
ENGINEERING STRUCTURES, 2008, 30 (01) :1-12
[29]   Bolted and welded connectors for the rehabilitation of composite beams [J].
Pathirana, Sameera Wijesiri ;
Uy, Brian ;
Mirza, Olivia ;
Zhu, Xinqun .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 125 :61-73
[30]   Flexural behaviour of composite steel-concrete beams utilising blind bolt shear connectors [J].
Pathirana, Sameera Wijesiri ;
Uy, Brian ;
Mirza, Olivia ;
Zhu, Xinqun .
ENGINEERING STRUCTURES, 2016, 114 :181-194