The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

被引:5
作者
Kroes, Maarten W. [1 ]
van Strijen, Marco J. L. [2 ]
Braak, Sicco J. [2 ]
Hoogeveen, Yvonne L. [1 ]
de Lange, Frank [1 ]
Kool, Leo J. Schultze [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Radiol & Nucl Med, POB 9101, NL-6500 HB Nijmegen, Netherlands
[2] St Antonius Hosp, Dept Radiol, POB 2500, NL-3430 EM Nieuwegein, Netherlands
关键词
C-arm; Cone-beam CT-guidance; Percutaneous biopsy; Laser guidance; Fluoroscopy time; INTERVENTIONAL RADIOLOGY; NEEDLE INTERVENTIONS; NAVIGATION SYSTEM; ACCURACY; EXPERIENCE; PUNCTURES; PHANTOM; SUITE; STAFF;
D O I
10.1007/s00270-016-1345-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
When using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times. Prospective data from 15 CBCT-guided biopsies of 8-65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions > 20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges). For biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83-333 s) compared to 87 s (44-190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001). The use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.
引用
收藏
页码:1322 / 1326
页数:5
相关论文
共 15 条
[1]   Real-Time 3D Fluoroscopy Guidance During Needle Interventions: Technique, Accuracy, and Feasibility [J].
Braak, S. J. ;
van Strijen, M. J. L. ;
van Leersum, M. ;
van Es, H. W. ;
van Heesewijk, J. P. M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) :W445-W451
[2]   Cone beam CT guidance provides superior accuracy for complex needle paths compared with CT guidance [J].
Busser, W. M. H. ;
Braak, S. J. ;
Futterer, J. J. ;
van Strijen, M. J. L. ;
Hoogeveen, Y. L. ;
de Lange, F. ;
Kool, L. J. Schultze .
BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1030)
[3]   Laser-Guided Cervical Selective Nerve Root Block with the Dyna-CT: Initial Experience of Three-Dimensional Puncture Planning with an Ex-Vivo Model [J].
Freundt, Miriam I. E. ;
Ritter, Manuel ;
Al-Zghloul, Mansour ;
Groden, Christoph ;
Kerl, Hans U. .
PLOS ONE, 2013, 8 (07)
[4]   C-Arm Cone-Beam CT Combined with a New Electromagnetic Navigation System for Guidance of Percutaneous Needle Biopsies: Initial Clinical Experience [J].
Kickuth, R. ;
Reichling, C. ;
Bley, T. ;
Hahn, D. ;
Ritter, C. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (07) :569-576
[5]   Assessment of Needle Guidance Devices for Their Potential to Reduce Fluoroscopy Time and Operator Hand Dose during C-Arm Cone-Beam Computed Tomography-guided Needle Interventions [J].
Kroes, Maarten W. ;
Busser, Wendy M. H. ;
Futterer, Jurgen J. ;
Arntz, Mark J. ;
Janssen, Caroline M. M. ;
Hoogeveen, Yvonne L. ;
de Lange, Frank ;
Kool, Leo J. Schultze .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (06) :901-906
[6]   Staff Doses in Interventional Radiology: A National Survey [J].
Mariano Sanchez, Roberto ;
Vano, Eliseo ;
Fernandez, Jose M. ;
Rosales, Francisco ;
Sotil, Jesus ;
Carrera, Francisco ;
Garcia, Maria A. ;
Soler, Maria M. ;
Hernandez-Armas, Jose ;
Martinez, Luis C. ;
Verdu, Jose F. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (11) :1496-1501
[7]   C-arm cone-beam CT: General principles and technical considerations for use in interventional radiology [J].
Orth, Robert C. ;
Wallace, Michael J. ;
Kuo, Michael D. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) :814-820
[8]   Live 3D guidance in the interventional radiology suite [J].
Racadio, John M. ;
Babic, Drazenko ;
Homan, Robert ;
Rampton, John W. ;
Patel, Manish N. ;
Racadio, Judy M. ;
Johnson, Neil D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) :W357-W364
[9]   Laser-guided percutaneous kidney access with the Uro Dyna-CT: first experience of three-dimensional puncture planning with an ex vivo model [J].
Ritter, M. ;
Rassweiler, M. -C. ;
Haecker, A. ;
Michel, M. S. .
WORLD JOURNAL OF UROLOGY, 2013, 31 (05) :1147-1151
[10]   The Uro Dyna-CT Enables Three-dimensional Planned Laser-guided Complex Punctures [J].
Ritter, Manuel ;
Rassweiler, Marie-Claire ;
Michel, Maurice Stephan .
EUROPEAN UROLOGY, 2015, 68 (05) :880-884