Assessment of the diagnostic sensitivity and specificity of an indirect ELISA kit for the diagnosis of Brucella ovis infection in rams

被引:25
作者
Praud, Anne [2 ]
Champion, Jean-Luc [3 ]
Corde, Yannick [1 ]
Drapeau, Antoine [1 ]
Meyer, Laurence [4 ,5 ]
Garin-Bastuji, Bruno [1 ]
机构
[1] ANSES, Hlth Anim Lab, EU OIE FAO Brucellosis Reference Lab, F-94706 Maisons Alfort, France
[2] French Agcy Food Environm & Occupat Hlth Safety A, Natl Vet Sch Alfort ENVA, USC Epidemiol Anim Infect Dis Unit Epi MAI, F-94700 Maisons Alfort, France
[3] Grp Def Sanit Alpes de Haute Provence, F-04000 Digne Les Bains, France
[4] Univ Paris 11, Hop Bicetre, AP HP, Epidemiol & Publ Hlth Serv, F-94276 Le Kremlin Bicetre, France
[5] Fac Med Paris Sud, INSERM, Ctr Res Epidemiol & Populat Hlth CESP, U1018, Le Kremlin Bicetre, France
来源
BMC VETERINARY RESEARCH | 2012年 / 8卷
关键词
Brucella ovis; Diagnostic tests; CFT; I-ELISA; Sensitivity; Specificity; Bayesian approach; LINKED-IMMUNOSORBENT-ASSAY; CONDITIONAL DEPENDENCE; TESTS; SERODIAGNOSIS; EPIDIDYMITIS; IMMUNOASSAY; VALIDATION; ANTIBODY; SHEEP; EWES;
D O I
10.1186/1746-6148-8-68
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated. The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. Results: After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se (I-ELISA) = 0.917 [0.822; 0.992], 95% Credibility Interval (Crl) compared to Se (CFT) = 0.860 [0.740; 0.967], 95% Crl). However, CFT was slightly more specific than I- ELISA (Sp (CFT) = 0.988 [0.947; 1.0], 95% Crl) compared to Sp (I-ELISA) = 0.952 [0.901; 1.0], 95% Crl). The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. Conclusions: The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the epidemiological context, screening objectives and the financial and practical constraints.
引用
收藏
页数:7
相关论文
共 34 条
  • [21] COMPARISON OF 3 SEROLOGICAL TESTS FOR BRUCELLA-OVISINFECTION OF RAMS USING DIFFERENT ANTIGENIC EXTRACTS
    MARIN, CM
    DEBAGUES, MPJ
    BLASCO, JM
    GAMAZO, C
    MORIYON, I
    DIAZ, R
    [J]. VETERINARY RECORD, 1989, 125 (20) : 504 - 508
  • [22] Bayesian statistic: An approach fitted to clinic
    Meyer, N.
    Vinzio, S.
    Goichot, B.
    [J]. REVUE DE MEDECINE INTERNE, 2009, 30 (03): : 242 - 249
  • [23] MUHAMMED SI, 1975, CORNELL VET, V65, P221
  • [24] Nunez-Torres E D, 1997, Rev Latinoam Microbiol, V39, P123
  • [25] OIE, 2011, MAN DIAGN TESTS VACC
  • [26] OIE, 2011, TERR AN HLTH COD
  • [27] Paolicchi F. A., 1992, Revista de Medicina Veterinaria (Buenos Aires), V73, P46
  • [28] Robles C. A., 1998, Veterinaria Argentina, V15, P119
  • [29] Rutjes A., 2007, HEALTH TECHNOL ASSES, V11, piii, ix, DOI [10.3310/hta11500, DOI 10.3310/HTA11500]