Three-dimensional gadolinium-enhanced MR angiography: Applications for abdominal imaging

被引:35
作者
Glockner, JF [1 ]
机构
[1] St Louis Univ Hosp, Dept Radiol, St Louis, MO 63110 USA
关键词
abdomen; MR; angiography; magnetic resonance (MR); maximum intensity projection; three-dimensional; vascular studies;
D O I
10.1148/radiographics.21.2.g01mr14357
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiography is a versatile technique that combines speed, superb contrast, and relative simplicity. It has a wide range of applications, particularly in the abdomen and pelvis, where superb images of the abdominal aorta and renal arteries are routinely obtained. Aneurysms, atherosclerotic lesions, and occlusions of the major mesenteric arteries are also well depicted. In addition, 3D gadolinium-enhanced MR angiography is ideal for noninvasive evaluation of the systemic and mesenteric veins and can be used to demonstrate parenchymal lesions in the liver, pancreas, kidneys, and other organs. It is also useful in staging genitourinary neoplasms: Parenchymal lesions, venous extension, and adenopathy are all clearly depicted. Three-dimensional gadolinium-enhanced MR angiography can be useful in the preoperative evaluation of potential transplant donors and recipients and in the evaluation of vascular complications following transplantation. Delayed 3D acquisitions of the kidneys, ureters, and bladder can be performed routinely to generate gadolinium-enhanced urograms and demonstrate obstruction, delayed function, filling defects, and masses. A variety of methods for increasing the speed and improving the resolution of 3D acquisition are currently under investigation. These include novel imaging and reformatting techniques and the use of intravascular contrast agents with much longer vascular half-lives.
引用
收藏
页码:357 / 370
页数:14
相关论文
共 69 条
[1]  
Baden JG, 1999, JMRI-J MAGN RESON IM, V10, P369, DOI 10.1002/(SICI)1522-2586(199909)10:3<369::AID-JMRI19>3.0.CO
[2]  
2-X
[3]   Renal artery stenosis and accessory renal arteries:: Accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography [J].
Bakker, J ;
Beek, FJA ;
Beutler, JJ ;
Hené, RJ ;
de Kort, GAP ;
de Lange, EE ;
Moons, KGM ;
Mali, WPTM .
RADIOLOGY, 1998, 207 (02) :497-504
[4]   Use of gadolinium-enhanced, ultrafast, three-dimensional, spoiled gradient-echo magnetic resonance angiography in the preoperative evaluation of living renal allograft donors [J].
Buzzas, GR ;
Shield, CF ;
Pay, NT ;
Neuman, MJ ;
Smith, JL .
TRANSPLANTATION, 1997, 64 (12) :1734-1737
[5]   Three-dimensional volume rendering of spiral CT data: Theory and method [J].
Calhoun, PS ;
Kuszyk, BS ;
Heath, DG ;
Carley, JC ;
Fishman, EK .
RADIOGRAPHICS, 1999, 19 (03) :745-764
[6]   Renal cancer: Preoperative evaluation with dual-phase three-dimensional MR angiography [J].
Choyke, PL ;
Walther, MM ;
Wagner, JR ;
Rayford, W ;
Lyne, JC ;
Linehan, WM .
RADIOLOGY, 1997, 205 (03) :767-771
[7]   Renal arterial stenosis: Prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography [J].
De Cobelli, F ;
Venturini, M ;
Vanzulli, A ;
Sironi, S ;
Salvioni, M ;
Angeli, E ;
Scifo, P ;
Garancini, MP ;
Quartagno, R ;
Bianchi, G ;
Del Maschio, A .
RADIOLOGY, 2000, 214 (02) :373-380
[8]   Renovascular disease in patients with hypertension: Detection with systolic and diastolic gating in three-dimensional, phase-contrast MR angiography [J].
deHaan, MW ;
Kouwenhoven, M ;
Thelissen, GRP ;
Koster, D ;
Kessels, AGH ;
deLeeuw, PW ;
vanEngelshoven, JMA .
RADIOLOGY, 1996, 198 (02) :449-456
[9]   Diagnosis of renal vascular disease with MR angiography [J].
Dong, Q ;
Schoenberg, SO ;
Carlos, RC ;
Neimatallah, M ;
Cho, KJ ;
Williams, DM ;
Kazanjian, SN ;
Prince, MR .
RADIOGRAPHICS, 1999, 19 (06) :1535-1554
[10]   Comparing contrast-enhanced breath-hold MR angiography and conventional angiography in the evaluation of mesenteric circulation [J].
Ernst, O ;
Asnar, V ;
Sergent, G ;
Lederman, E ;
Nicol, L ;
Paris, JC ;
L'Herminé, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :433-439