The influence of the method of data analysis on the reported accuracy of automated blood pressure measuring devices

被引:6
|
作者
Braam, RL [1 ]
Thien, T [1 ]
机构
[1] Univ Med Ctr, Dept Internal Med, Div Hypertens & Vasc Pathol, NL-6500 HB Nijmegen, Netherlands
关键词
blood pressure measurement; accuracy of blood pressure measuring device; British Hypertension Society protocol;
D O I
10.1097/00004872-200110000-00009
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To show that different methods of data analysis affect the grading that blood pressure measuring devices achieve according to the British Hypertension Society (BHS)-protocol. Methods Based on the somewhat unclear description of the exact method of data analysis in the BHS-protocol four different methods can be discerned. The effect on the grading-results is calculated for these four different options. Results and Conclusions It is shown that using these four different options the achieved grade can range for diastolic blood pressure from C (option 1) to almost A (option 4) and for systolic blood pressure from D (option 1) to B (option 4). Different researchers may well have used different methods. Option 1 is the method that should be used. Also it is stated that the systematic error and the standard deviation of differences (SDD) are measures that give more insight to describe a device's performance. Calculating the grades after correction for the systematic error shows its influence and that of the SDD on the reported accuracy of a blood pressure measuring device. (C) 2001 Lippincott Williams & Wilkins.
引用
收藏
页码:1765 / 1767
页数:3
相关论文
共 50 条
  • [1] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Jennifer S. Ringrose
    Raj Padwal
    Journal of Human Hypertension, 2023, 37 : 101 - 107
  • [2] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Ringrose, Jennifer S.
    Padwal, Raj
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (02) : 101 - 107
  • [3] The quest for accuracy of blood pressure measuring devices
    O'Brien, Eoin
    Stergiou, George S.
    Turner, Martin J.
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (07): : 1092 - 1095
  • [4] Journal of Human Hypertension special issue on the accuracy of automated blood pressure measuring devices
    James E. Sharman
    Journal of Human Hypertension, 2023, 37 : 91 - 92
  • [5] Journal of Human Hypertension special issue on the accuracy of automated blood pressure measuring devices
    Sharman, James E.
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (2) : 91 - 92
  • [6] THE ACCURACY OF AUTOMATED BLOOD-PRESSURE MEASURING DEVICES IN PATIENTS WITH CONTROLLED ATRIAL-FIBRILLATION
    STEWART, MJ
    GOUGH, K
    PADFIELD, PL
    JOURNAL OF HYPERTENSION, 1995, 13 (03) : 297 - 300
  • [7] Is the accuracy of blood pressure measuring devices underestimated at increasing blood pressure levels?
    Braam, RL
    Thien, T
    BLOOD PRESSURE MONITORING, 2005, 10 (05) : 283 - 289
  • [8] Measuring blood pressure in pregnancy and postpartum: assessing the reliability of automated measuring devices
    Lan, Patrick G.
    Clayton, Philip A.
    Hyett, Jon
    Gillin, Adrian G.
    HYPERTENSION IN PREGNANCY, 2014, 33 (02) : 168 - 176
  • [9] Accuracy of ankle-brachial index obtained by automated blood pressure measuring devices in patients with diabetes mellitus
    Ena, Javier
    Lozano, Teresa
    Verdu, Gema
    Argente, Carlos R.
    Gonzalez, Victor L.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2011, 92 (03) : 329 - 336
  • [10] Accuracy of the automated oscillography electronic device in measuring blood pressure in children
    Zhang, Yi
    Cheng, Yi
    Wang, Qian
    Jiang, Yuan
    Yan, Weili
    CARDIOLOGY, 2013, 126 : 18 - 18